1. Applications
Applications
TM03 3903 1106
TM05 5874 2110
Fig. 2 HS pump in industrial pressure boosting
GR 2910
Commercial systems
• Air-conditioning and chilled-water systems
• Water condensing systems and cooling towers Fig. 3 HS pump in sprinkler irrigation
Industrial systems
• Process cooling and chilled water systems
• Industrial heating systems
• Wash down and cleaning systems
3
2 HS
4
HS
3
3. Performance range
Performance range
Grundfos HS pumps are available with 2-, 4- or 6-pole 1. Go into the relevant performance range chart.
motors. 2. Find your duty point.
The next three pages show the performance range 3. Note which pump type covers your duty point.
covered by these three motor types. 4. Go to the “Pump range” on page 9 and find the
selected pump. Go to the listed page number in the
Knowing your required duty point, use the performance
“Curve charts and technical data” on page 29 to find
ranges like this:
more detailed information on your chosen pump.
HS 2-pole
500
Q [m³/h]
Q [l/s]
2-pole, 60 Hz
400
HS
125-100-305
80 90 100
300
125-100-280
250
70
60
200
100-80-242
50
150
40
30
100
80
65-50-242
20
60
50
40
9 10
30
8
25
7
6
20
150
120
100
80
60
50
40
30
20
[kPa] [m]
H
2000
1000
900
800
700
600
500
400
300
200
p
5
Performance range
3
6
H H
[m] [ft] HS
800 4-pole, 60 Hz
HS 4-pole
200
600
350-250-630
500
400 200-150-508
100 200-150-483 35
0-
300-200-489 25
0-
49
80 8
250
70 125-100-388
200 20
60 0-1
50 25
0-2 30
150-125-381 - 38 00 0-2
50 1 -38 50
1 -38
150 1
65-50-331 100-80-356
40
400-350-397
30 100 125-100-305
80 30
0-
65-50-242 25
200-150-305C 0-
20 30
5
60
100-80-242 150-125-305
50
40
250-200-305
10
1 25 -10
25
0-2
80
20
15
100 150 200 250 300 400 500 600 800 1000 1500 2000 3000 4000 6000 10000 15000
Q [US GPM]
23 30 40 50 60 70 80 100 200 300 400 500 600 800 1000 2000 Q [m³/h]
TM05 7254 0813
HS
HS
p H
[kPa] [m] HS
100 6-pole, 60 Hz
HS 6-pole
900
800 80
700 350-250-630
600 60
500 50
200-150-483 200-150-508
400 40
300-200-489 350-250-498 350-300-508
300 30
200 20
300-250-381
15
250-200-381 400-350-397
12
100 10
90 300-250-305
80 8
70
60 6
50 5
40 4
80 100 150 200 250 300 400 500 600 800 1000 1500 2000 2500 3000
Q [m³/h]
23 30 40 50 60 70 80 90 100 200 300 400 500 600 Q [l/s]
TM04 0299 4410
7
Performance range
3
4 HS
4. Product range
Product range
Pump configurations
Standard configuration Optional configuration
Pump casing Ductile iron (PN 16) Cast iron (PN 10)
Shaft Stainless steel Steel
Shaft sleeve Bronze -
Impeller Bronze • Aluminium bronze
• Stainless steel
Sleeve Bronze Stainless steel
Wear rings Bronze Stainless steel
Coupling Spacer coupling Pin and bush (up to 160 kW motors)
Shaft seal Mechanical seal: Mechanical seal:
• BBVP • BBQV, BBQE
Stuffing box:
• SNEK, (internal flushing/recirculation
line is included)
Flange EN 1092-2 (DIN 2501), PN 16 EN 1092-2 (DIN 2501), PN 10
Flushing line - Nylon, stainless steel, copper
Motor IE2 MMG-G IE1, IE3 (MG)
Motor bearing - Insulated bearing
Pump direction of rotation CW - clockwise CCW - counter-clockwise
To a great extent the pumps can be adapted to the requirements of the individual customer. For customised solutions,
contact your local Grundfos company.
Note: IE2 standard. IE3 optional
8
HS
4
Pump range HS pumps are available with 2-, 4- or 6-pole motors;
Product range
other motor pole numbers are available on request.
The table below gives an overview of the HS pump
range (PN16). The PN 10 pump range does not include HS pumps are available in several different
all impeller sizes (see individual performance curves). construction types, all with mechanical shaft seal.
9
5 HS
5. Identification
Identification
Nameplate
The nameplate on the pump gives the details of the pump.
/241.3
100
xxxxxxxx
Type key
HS 65 -50 -242 /241.3 5/1 F A BBVP 1
Type range
Nominal diameter of
suction port
Nominal diameter of
discharge port
Maximum impeller diameter
(If suffix is used, “x” = different
impeller design)
Actual impeller diameter
Pump variant:
5/1 = Pump with motor and base frame
5/2 = Bare shaft pump with base frame
5/3 = Bare shaft pump
Code for pipework connection:
F = EN flange (to EN 1092-2)
Code for materials (pump casing and impeller):
A = Ductile iron pump casing with bronze impeller
B = Cast iron pump casing with bronze impeller
Q = Ductile iron pump casing with stainless steel
impeller
S = Cast iron pump casing with stainless steel impeller
Code for shaft seal or stuffing box:
BBVP
BBQV
BBQE
SNEK
Direction of rotation:
(Pump direction of rotation seen from motor end)
1 = Clockwise
2 = Counter-clockwise
10
HS
6
6. Construction
Construction
Grundfos HS horizontal split-case pumps are available
in four different construction types.
All four construction types are available with stuffing
boxes and packing rings as an option. There are small
differences within each construction type. For further
information, see detailed exploded views of all variants
in WebCAPS.
Sectional view
11
6 HS
Sectional view
113d
11a
54
114a
79 124
6b 116a
12
HS
6
HS pump, construction type 3
Construction
Sectional view
13
6 HS
Sectional view
14
HS
6
HS pump, typical end view
Construction
(Non-drive end)
15
6 HS
16
HS
6
Tap and drain plug dimensions
Construction
Pump Model Discharge Gauge Tap 20C Suction Gauge Tap 20B Case Drain 20A Discharge Vent 17 (Dome) Suction Vent 20E (Dome)
HS 65-50-242 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS65-50-331 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS100-80-242 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS100-80-356 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS125-100-280 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS125-100-305 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS125-100-388 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS150-125-305 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS150-125-381 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS200-150-305C 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS200-150-381 (2) 1/4 (2) 1/4 (4) 1/2 1/2 (4) 1/4
HS200-150-483 1/4 1/4 (4) 1/2 1/2 (2) 1/4; (2) 1/2
HS200-150-508 (2) 1/4 (2) 1/4 (4) 1/2 1/2 (4) 1/4
HS250-200-305 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS250-200-381 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS300-200-489 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS300-250-305 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS300-250-381 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS65-50-331 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS100-80-242 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS100-80-356 1/4 1/4 (4) 1/2 1/2 (4) 1/4
HS125-100-280 (2) 1/4 (2) 1/4 (4) 1/2 1/2 (4) 1/4
17
6 HS
Impeller
The HS impeller (pos. 49) is a closed double-suction
impeller. The impeller has inflow of liquid from both
sides and is locked in position by a threaded shaft
sleeve.
TM04 0475 0708
18
HS
6
Wear rings Motor
Construction
HS pumps have wear rings (pos. 45) between impeller The motor is a totally enclosed, fan-cooled motor with
and pump casing. main dimensions according to IEC and DIN standards.
As the name indicates, the wear rings protect the pump Motor efficiency is categorised according to EN 60034-
casing against wear. The wear rings act as seal 2-1:2007:
between impeller and pump casing.
• IE3: MG motors
When the wear rings become worn, the efficiency of the • IE2: MMG-G motors
pump will be reduced, and the wear rings should be
replaced. Motors available for the HS pump range
19
6 HS
• Limited corrosion resistance, 5 < pH < 9, depending The packing rings consist of braided material which is
Construction
on ceramic type. effective for ensuring long service life for packing rings
• Relatively good dry-running properties. However, while protecting the shaft (sleeve). When fitted, the
thermal cracks may occur in case of a sudden influx packing rings are symmetrical, having parallel facings
of water to a hot seal after a period of dry running or that prevent tilting.
similar condition.
• The carbon of the seal offers properties very similar
to the carbon/tungsten carbide seal. However,
compared to the carbon/tungsten carbide seal, the
pressure and temperature ranges are limited.
Stuffing boxes
Stuffing boxes of the type SNEK are available as an
alternative to mechanical shaft seals.
20
HS
7
7. Operating conditions
Operating conditions
Ambient temperature and altitude 0.5 metres head. NPSH appears from the performance
curves in “Performance curves-technical data” on
The ambient temperature and the installation altitude
page 31.
are important factors for the motor life, as they affect
the life of the bearings and the insulation system.
Ambient temperature must not exceed +40 °C. Flow rate
If the ambient temperature exceeds +40 °C or if the Minimum flow rate
motor is installed more than 1000 m above sea level,
The pump must not run against a closed discharge
the motor must not be fully loaded due to the low den-
valve, as this will cause an increase in temperature/
sity and consequently low cooling effect of the air. In
such cases, it may be necessary to use a motor with a formation of steam in the pump. This may cause shaft
higher output. damage, impeller erosion, short life of bearings, stuffing
boxes with packing rings or mechanical seals due to
stress or vibration.
P1
[%] The minimum, continuous flow rate must be at least
100 25 % of the flow rate at best-efficiency point (BEP).
90
80 Maximum flow rate
70 The maximum flow rate must not exceed the value
60 stated on the nameplate. If the maximum flow rate is
TM00 2189 1598
50
exceeded, cavitation and overload may occur.
20 25 30 35 40 45 50 55 60 65 70 75 80
t [°C]
1000 2250 3500 m Maximum particle size
The table shows the permissible size of particles.
Fig. 19 Relationship between motor output (P2) and am-
bient temperature Maximum particle size
Pump type (non-abrasive particles)
[mm]
Example:
HS 65-50-242 4.8
Fig. 19 shows that the load of the motor must be
HS 65-50-331 4.1
reduced to 88 % when installed 3500 m above sea HS 100-80-242 7.9
level. At an ambient temperature of 70 °C the load of HS100-80-356 7.9
the motor must be reduced to 78 % of the rated output. HS 125-100-280 9.7
Liquid temperatures and shaft seals HS 125-100-305 19.1
The maximum liquid temperature marked on the pump HS 125-100-388 6.4
HS 150-125-305 16.0
nameplate depends on the mechanical shaft seal used:
HS 150-125-381 19.1
• Temperature range for NBR (BBVP - standard): HS 200-150-305C 25.4
0 °C to +100 °C. HS 200-150-381 20.6
HS 200-150-483 19.1
• Temperature range for FKM (BBQV - optional): HS 200-150-508 19.1
+15 °C to +100 °C. HS 250-200-305 22.4
• Temperature range for EPDM (BBQE - optional): HS 250-200-381 25.4
+15 °C to +135 °C. HS 300-200-489 26.2
HS 300-250-305 25.4
Minimum temperature of -12°C can be achieved for HS 300-250-381 31.8
certain applications. Contact the factory for specific HS 350-250-498 30.5
information. HS 350-250-630 29.7
HS 350-300-508 47.5
Pressure HS 400-350-397 47.5
Maximum pressure
• Pump made of ductile iron: 16 bar
• Pump made of cast iron: 10 bar.
• 25 bar options available on select models.
21
8 HS
8. Installation
Installation
Mechanical installation
Vibration dampers
Fig. 20 HS pump with accessibility for inspection and
A specific application may call for vibration dampers to headroom for the use of an overhead crane
prevent pump vibrations from being transmitted to the
building or the pipework. In order to select the right Foundation
vibration damper, you need this information: It is recommended that you install the pump on a
• Forces transferred through the damper. concrete foundation which is heavy enough to provide
permanent and rigid support for the entire pump. The
• Motor speed. In the case of speed control, this must
foundation must be capable of absorbing any vibration,
also be taken into account.
normal strain or shock. As a recommendation, the
• Desired dampening in %
weight of the concrete foundation should be 3 times the
(recommended value: 70 %).
weight of the complete pump unit. For specific
The selection of vibration damper differs from requirements, please consult the contractor or the
installation to installation. In certain cases a wrong engineer, or comply with established industry
damper may increase the vibration level. Vibration standards.
dampers should therefore be sized by the supplier of
the vibration dampers. In installations where silent operation is particularly
important, a foundation with a mass up to 5 times that
Expansion joints of the complete pump unit is recommended.
Expansion joints provide these advantages:
Grouting
• Absorption of thermal expansion and contraction of
pipework caused by variations in liquid temperature.
• Reduction of mechanical influences in connection Base frame
Grout
with pressure surges in the pipework.
5-10 mm
19 to 32 mm left in place
displacement or misalignment of flanges. grout
Top of
The expansion joints should be fitted at a minimum Formwork foundation
distance of 2 pipe diameters (DN) away from the pump (rough)
flange on the suction side. This prevents turbulence in
Fig. 21 Sectional view of foundation with foundation bolt,
the joints, thus ensuring optimum suction conditions
grouting and base frame
and minimum pressure drop on the discharge side.
Grouting compensates for uneven foundation,
At flow velocities > 2.4 m/s, it is recommended to fit
distributes weight of unit, dampens vibrations and
larger expansion joints matching the pipework.
prevents shifting. Use an approved, non-shrinking
grout. If you have questions or doubts about the
Location
grouting, please contact an expert on grouting.
Install the pump as close as possible to the supply of
pumped liquid and with the shortest and most direct
suction pipe practical.
22
HS
8
Measuring instruments Suction piping
Installation
Note: The sizing and installation of the suction piping is
To ensure continuous monitoring of operation, we
extremely important.
recommend you to install pressure gauges on pump
suction and discharge flanges. The pressure gauge on Locate the pump below system level whenever
the suction side must be capable of measuring vacuum. possible. This will facilitate priming, assure a steady
The pressure gauge tappings should only be opened liquid flow and provide a positive suction head.
for test purposes. The measuring range of the
Many NPSH problems can be avoided if the suction
discharge side pressure gauge should be 20 % above
piping is properly installed.
the maximum pump discharge pressure.
When measuring with pressure gauges on the pump System types
flanges, please note that a pressure gauge does not These pumps can be installed in two types of system:
register dynamic pressure (velocity pressure). On HS 1. Closed systems or open systems where the liquid
pumps, the diameters of the suction and discharge level is above the pump inlet (flooded systems),
flanges are different which results in different flow meaning that a positive1) inlet pressure will be
velocities in the two flanges. Consequently, the available.
pressure gauge on the discharge flange will not show 2. Open systems where the liquid level is below the
the pressure stated in the technical documentation, but pump inlet (suction lift), meaning that a negative 1)
a value which may be lower. inlet pressure will be available.
1) Positive or negative inlet pressure in relation to ambient atmospheric
Piping pressure.
General precautions
When installing the piping, observe these precautions: Eccentric reducer
23
8 HS
(Closed systems and open systems where the liquid horizontal planes
level is above the pump inlet). Avoid high spots, such as loops, as they will collect air
and throttle the system or lead to uneven pumping.
Correct
Correct
Eccentric reducer
Correct
Eccentric reducer
Pipe sloping up
towards pump confined space
Eccentric reducer
Wrong
TM04 0096 4907
Air pocket
TM04 0097 4907
24
HS
8
Suction piping with a horizontal elbow in the feed Valves in suction piping
Installation
line If the pump is operating under static suction lift
Make sure that the liquid flow is evenly distributed to conditions, install a non-return valve in the suction pipe
both sides of the double-suction impellers. to avoid having to prime the pump each time it is
There is always an uneven, turbulent flow through an started. The non-return valve should be of the flap type
elbow. See Fig. 31. If an elbow is installed in the suction or a foot-valve with a minimum of pressure loss.
pipe near the pump in a position other than vertical,
more liquid will enter one side of the impeller than the Discharge piping
other. This will result in heavy, unbalanced thrust loads The discharge pipe is usually preceded by a non-return
overheating the bearings, causing rapid wear and valve and a discharge isolating/throttle valve. The non-
reducing the hydraulic performance. return valve protects the pump against excessive back-
pressure and reverse rotation of the pump and prevents
Correct back flow through the pump in case of operational stop
or failure of the motor.
In order to minimise friction losses and hydraulic noise
in the pipework, flow velocities should not exceed 3 m/
s (9 ft/sec) in the discharge pipe (port).
On long horizontal runs, it is desirable to keep the
≥ 10 X DN plus
expansion joint piping as level as possible.
10 x DN
DN
Avoid high spots, such as loops as they will collect air
TM04 0150 4907
Auxiliary piping
1. Drains
Install drain pipes from pump casing and stuffing
Fig. 30 Recommended suction pipe installation with boxes to a convenient disposal point.
a length of straight pipe between horizontal 2. Pumps fitted with stuffing boxes
elbow and pump When suction pressure is below ambient pressure,
supply the stuffing boxes with liquid to provide
Wrong lubrication and prevent the ingress of air. This is
normally achieved via a flushing pipe from the pump
discharge side to the stuffing box. A control valve or
orifice plate may be fitted in the flushing pipe to
control the pressure to the packing gland/stuffing
box.
If the pumped liquid is dirty and cannot be used for
flushing the seals, we recommend a separate clean,
compatible liquid supply to the stuffing box at 1 bar
(15 psi) above the suction pressure.
3. Pumps fitted with mechanical seals
TM04 0149 4907
25
9 HS
9. Selection of product
Selection of product
Efficiency 20 /234.3
Max. flow
If you expect the pump to always operate in the same 16 /210.8 rate
NPSH
margin
[m]
duty point, select a pump which is operating in a duty 12 12
point corresponding to the best efficiency of the pump.
8 8
In case of varying consumption, select a pump whose
4 NPSH 4
best efficiency falls within the duty range covering the
26
HS
9
In some cases, however, the input power actually Method 1
Selection of product
decreases as the flow rate increases. It will thus be Add a safety margin as outlined in ISO 5199 to the
found at some other point within this flow range. This is maximum P2 found when determining parameter 1.
typically the case when the impeller is trimmed to the
(Grundfos recommends the addition of a safety margin
smallest diameter.
in accordance with this standard; default in WebCAPS.)
Decrease of P2 with increase of flow
Required pump power up to Motor power
[kW] P2 [kW]
H
[m] 568 630
HS 300-250-305
505 560
40 ISO 9906 Grade 2
450 500
36 360 400
/304.8
320 355
32 284 315
/281.3 225 250
28
180 200
24 /257.8 144 160
119 132
20 /234.3
99 110
81 90
16 /210.8
NPSH
68 75
[m]
12 12 49 55
40 45
8 8 32.5 37
Duty point 26 30
4 NPSH 4
Max. flow rate margin 19 22
15.9 18.5
0 0
12.8 15
P2 0 200 400 600 800 1000 Q [m³/h] Eta 9.1 11
[kW] [%]
6.1 7.5
80 80
4.3 5.5
60 /304.8 60
/281.3
3.2 4
TM04 0350 0608
40 40 2.3 3
/257.8
20 /234.3 20 1.7 2.2
/210.8
P2 max 1.1 1.5
0 0
0 200 400 600 800 1000 Q [m³/h] Fig. 35 Safety margins according to ISO 5199
27
10 HS
Pumped liquids
We recommend HS pumps for thin, clean and non-
aggressive, non-explosive liquids, not containing solid
particles or fibres. The liquid must not attack the pump
materials chemically or mechanically.
The mechanical shaft seal must be suitable for the
liquid.
Water in heating and ventilating systems often contains
additives to prevent negative effects such as system
corrosion or calcareous deposits. If you want to use the
pump for such liquids and if the temperature is above
80 °C, use special shaft seals to avoid crystallization/
precipitation between the seal faces.
28
HS
11
110 /222.3
70 NPSH
/171.5 [m]
60 30
50 25
40 20
30 15
40 /222.3 40
30 /206.4 30
The power
20
/190.5
20 curves indicate
pump input
/171.5
power [P2] for the
10 10
TM03 2844 5005
pumps shown
0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
29
11 HS
• Tolerances according to ISO 9906, Grade 2. The requested duty point for every split case pump
• The curves show pump performance with different produced in Europe is tested according to ISO 9906,
impeller diameters at the nominal speed. Grade 2, and without certification.
• The bold part of the curves show the In case of pumps ordered on the basis of impeller
recommended operating range. diameter only (no requested duty point), the pump will
• Do not operate the pump along the thin parts of the be tested at the best efficiency point.
curves. If your duty point lies here, you should
select a smaller or larger pump type. The primary duty point is guaranteed by a certified
performance test. Additional point(s), on request, are
• Do not use the pumps at minimum flow rates below
offered for reference only. Testing certificate has to be
0.1 x Qmax stated on the pump name plate because
of the risk of overheating of the pump. ordered separately.
30
12
H H
[m] [ft]
/241.3
420 HS 65-50-242
400 60 Hz, n = 3550 min-1
120
ISO 9906 Grade 2
380
340
100
320
/206.4
300
90
280
80 /190.5
260
240
70
220
/171.5
60 200
180
50 160
140
40 NPSH
120 [ft] [m]
30 100 100 30
80 80
20 20
60 60
40 40
10 10
20 NPSH 20
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
140 70
100
120 60
80 /190.5 /206.4 /222.3 /241.3
/171.5
100 50
60 80 40
/241.3
60 30
40 /222.3
40 /206.4 20
20 /190.5
20 /171.5 10
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [m³/h]
TM05 7523 1113
0 50 100 150 200 250 300 350 400 450 500 550 Q [US GPM]
31
12
Performance curves-technical data
Dimensional sketches
HS standard, 65-50-242
32
12
H H
[m] [ft]
420 /241.3 HS 100-80-242
400 60 Hz, n = 3550 min-1
120
ISO 9906 Grade 2
380
110 360
/222.3
340
100
320
300 /203.2
90
280
80 260
240 /184.2
70
220
60 200
/165.1
180
50 160
140
40 NPSH
120 [ft] [m]
30 100 100 30
80 80
20 20
60 60
40 40
10 10
20 NPSH 20
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
160 80
140 70
100
/241.3
120 /241.3 60
80 /165.1 /184.2 /203.2 /222.3
100 50
/222.3
60 80 40
/203.2
60 30
40
/184.2
40 20
/165.1
20
20 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 Q [m³/h]
TM05 7524 1113
0 100 200 300 400 500 600 700 800 900 1000 Q [US GPM]
33
12
Performance curves-technical data
Dimensional sketch
HS standard, 100-80-242
34
12
H H
[m] [ft]
440 /261.6 HS 125-100-280
130
420 60 Hz, n = 3550 min-1
400 ISO 9906 Grade 2
120
380
110 360 /237.5
340
100
320
90 300
/213.4
280
80 260
240
70 /189.2
220
60 200
180 /165.1
50 160
NPSH
140 [ft] [m]
40
120 120
30 100 100 30
80 80
20 20
60 60
40 40
10 NPSH 10
20 20
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
320 80
280 70
200 /237.5 /261.6
/213.4
240 /189.2 60
160 /165.1
200 50
/261.6
120 160 40
120 /237.5 30
80
80 /213.4 20
40 /189.2
40 /165.1 10
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300 320 340 Q [m³/h]
TM05 7525 1113
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 Q [US GPM]
The grey line represents a maximum shaft load of 2.7 kW/100 rpm when pumping water If the required shaft load
exceeds 2.7 kW/100 rpm, use a larger pump. Be aware that the curves will change when pumping liquids with a higher
density and/or viscosity than water.
35
12
Performance curves-technical data
Dimensional sketch
HS standard, 125-100-280
36
12
H H
[m] [ft]
120
400 HS 125-100-305
/237.5
380 60 Hz, n = 3550 min-1
ISO 9906 Grade 2
110 360
340 /222.6
100
320
300 /207.6
90
280
80 260 /192.7
240
70
220 /177.8
60 200
180
50 160
NPSH
140
40 [ft] [m]
120 120
30 100 100 30
80 80
20 20
60 60
40 40
10 NPSH 10
20 20
0 0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 480 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
400 80
250 350 70
300 /237.5 60
200 /222.6
250 /207.6 50
0 0 0
0 40 80 120 160 200 240 280 320 360 400 440 480 Q [m³/h]
TM05 7526 1113
0 200 400 600 800 1000 1200 1400 1600 1800 2000 Q [US GPM]
The grey line represents a maximum shaft load of 2.7 kW/100 rpm when pumping water If the required shaft load
exceeds 2.7 kW/100 rpm, use a larger pump. Be aware that the curves will change when pumping liquids with a higher
density and/or viscosity than water.
37
12
Performance curves-technical data
Dimensional sketch
HS standard, 125-100-305
38
12
H H
[m] [ft]
35 HS 65-50-242
110 60 Hz, n = 1780 min-1
/241.3 ISO 9906 Grade 2
100
30
90
/222.3
25
80
/206.4
70
20
/190.5
60
/171.5
15 50
40
NPSH
10
[ft] [m]
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 10 20 30 40 50 60 70 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
14
10
12
8 /171.5 /190.5 /206.4 /222.3
/241.3
10
6 /241.3
8
/222.3
6
4
/206.4
4
/190.5
2
2 /171.5
0 0 0
0 10 20 30 40 50 60 70 Q [m³/h]
TM05 7527 1113
39
12
Performance curves-technical data
Dimensional sketch
HS standard, 65-50-242
40
12
H H
[m] [ft]
HS 65-50-331
200 60 Hz, n = 1780 min-1
60
ISO 9906 Grade 2
/330.2
180
50 /304.7
160
140 /279.4
40
120
/254.0
30 100
/228.6
80
NPSH
20
[ft] [m]
60 30
8
40 20 6
10
4
20 10
NPSH
2
0 0 0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
60 60
40
50 /330.2 50
/304.7
30 /279.4
40 /254.0 40
/228.6
30 30
20
/330.2
20 /304.7 20
/279.4
10
/254.0
10 /228.6 10
0 0 0
0 10 20 30 40 50 60 70 80 Q [m³/h]
TM05 7556 1113
41
12
Performance curves-technical data
Dimensional sketch
HS standard, 65-50-331
42
12
H H
[m] [ft]
35 HS 100-80-242
110 60 Hz, n = 1780 min-1
/241.3 ISO 9906 Grade 2
100
30
90
/222.3
25
80
/203.2
70
20
60 /184.2
15 50 /165.1
40
NPSH
10
[ft] [m]
30 15
4
20 10 3
5
NPSH 2
10 5
1
0 0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
32 80
28 70
20
/241.3
24 /222.3 60
/184.2 /203.2
16 /165.1
20 50
12 16 /241.3 40
12 /222.3 30
8
/203.2
8 20
4 /184.2
4 /165.1 10
0 0 0
0 10 20 30 40 50 60 70 80 90 100 110 120 Q [m³/h]
TM05 7557 1113
0 50 100 150 200 250 300 350 400 450 500 Q [US GPM]
43
12
Performance curves-technical data
Dimensional sketch
HS standard, 100-80-242
44
12
H H
[m] [ft]
70
/355.6
HS 100-80-356
220 60 Hz, n = 1780 min-1
ISO 9906 Grade 2
200
60
/330.2
180
50 /304.8
160
140 /279.4
40
120
/254.0
30 100
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
60 /355.6 70
/304.8 /330.2
40 /254.0 /279.4
/355.6
50 60
30 40 /330.2 50
30 /304.8 40
20
/279.4
20 30
/254.0
10
10 20
0 0 10
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
TM05 7558 1113
0 100 200 300 400 500 600 700 800 Q [US GPM]
45
12
Performance curves-technical data
Dimensional sketch
HS standard, 100-80-356
46
12
H H
[m] [ft]
40
HS 125-100-280
130
/279.4 60 Hz, n = 1780 min-1
ISO 9906 Grade 2
120
35
110
100 /250.7
30
90
25
80
/222.0
70
20
60
/193.6
15 50 NPSH
[ft] [m]
40 /165.1 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
40 80
35 70
25
/279.4
30 /222.0 /250.7 60
20 /193.6
25 /279.4 50
/165.1
15 20 40
/250.7
15 30
10
/222.0
10 20
5 /193.6
5 10
/165.1
0 0 0
0 20 40 60 80 100 120 140 160 180 200 Q [m³/h]
TM05 7559 1113
0 100 200 300 400 500 600 700 800 Q [US GPM]
47
12
Performance curves-technical data
Dimensional sketch
HS standard, 125-100-280
48
12
H H
[m] [ft]
160
/304.8 HS 125-100-305
60 Hz, n = 1780 min-1
150 ISO 9906 Grade 2
45
140
40 130 /273.1
120
35
110
/241.3
30 100
90
25
80
/209.6
70
20
60
/177.8
15 50 NPSH
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
80 80
/304.8
70 70
50 /273.1
/241.3
60 60
40 /209.6
50 50
/177.8 /304.8
30 40 40
/273.1
30 30
20
20 /241.3 20
10 /209.6
10 10
/177.8
0 0 0
0 20 40 60 80 100 120 140 160 180 200 220 240 260 280 Q [m³/h]
TM05 7560 1113
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [US GPM]
49
12
Performance curves-technical data
Dimensional sketch
HS standard, 125-100-305
50
12
H H
[m] [ft]
300
HS 125-100-388
90
/388.0 60 Hz, n = 1780 min-1
280 ISO 9906 Grade 2
80 260
/346.0
240
70
220
60 200
/311.0
180
50
160
/276.2
140
40
120
/241.3
30 100
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 50 100 150 200 250 300 350 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
160 80
60 /311.0 30
40
40 /276.2 20
20 /241.3
20 10
0 0 0
TM05 7561 1113
51
12
Performance curves-technical data
Dimensional sketch
HS standard, 125-100-388
52
12
H H
[m] [ft]
HS 150-125-305
180 60 Hz, n = 1780 min-1
ISO 9906 Grade 2
50 /304.8
160
140
40 /273.1
120
/241.3
30 100
NPSH
[ft] [m]
80 40 12
/209.6
20
60 30
/177.8
8
40 20
10
4
20 10
NPSH
0 0 0 0
0 50 100 150 200 250 300 350 400 Q [m³/h]
P2 Eff
[kW] [%]
90 90
80 80
70 /304.8 70
/241.3 /273.1
60 /209.6 60
/177.8 /304.8
50 50
40 40
/273.1
30 30
/241.3
20 20
/209.6
10 10
/177.8
0 0
0 50 100 150 200 250 300 350 400 Q [m³/h]
TM05 7547 1113
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
53
12
Performance curves-technical data
Dimensional sketch
HS standard, 150-125-305
54
12
H H
[m] [ft]
280
HS 150-125-381
60 Hz, n = 1780 min-1
/381.0
80 260 ISO 9906 Grade 2
240
70
220
/342.9
60 200
180
50 /304.8
160
140
40
/266.7
120
30 100
/228.6
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
NPSH 5
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
320 80
/304.8 /342.9 /381.0
280 /266.7 70
200
240 /228.6 60
160
200 50
120 30
80
/342.9
80 20
/304.8
40
40 /266.7 10
/228.6
0 0 0
0 50 100 150 200 250 300 350 400 450 500 Q [m³/h]
TM05 7548 1113
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200Q [US GPM]
55
12
Performance curves-technical data
Dimensional sketch
HS standard, 150-125-381
56
12
H H
[m] [ft]
170 HS 200-150-305C
/304.8
50 60 Hz, n = 1780 min-1
160
ISO 9906 Grade 2
150
45
140
/273.1
40 130
120
35
110
/241.3
30 100
90
25 /209.6
80
70
20
60 /177.8
50 NPSH
15
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 NPSH 10
2
0 0 0 0
0 100 200 300 400 500 600 700 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
280 90
200
240 80
160 /304.8
200 /273.1 70
120 50
80 /177.8
/304.8
80 40
/273.1
40
40 /241.3 30
/209.6
/177.8
0 0 20
0 100 200 300 400 500 600 700 Q [m³/h]
TM05 7550 1113
57
12
Performance curves-technical data
Dimensional sketch
HS standard, 200-150-305C
58
12
H H
[m] [ft]
80
HS 200-150-381
260
/381.0 60 Hz, n = 1780 min-1
ISO 9906 Grade 2
240
70
220
/342.9
200
60
180
50 /304.8
160
140
40 /266.7
120
30 100
/228.6
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 20
NPSH 5
0 0 0 0
0 100 200 300 400 500 600 700 800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
320 90
280 80
200
/304.8 /342.9 /381.0
240 /266.7 70
/228.6
160
200 /381.0 60
120 160 50
/342.9
120 40
80 /304.8
80 30
/266.7
40
40 /228.6 20
0 0 10
0 100 200 300 400 500 600 700 800 Q [m³/h]
TM05 7551 1113
59
12
Performance curves-technical data
Dimensional sketch
HS standard, 200-150-381
60
12
H H
[m] [ft]
140 HS 200-150-483
440 60 Hz, n = 1780 min-1
/482.6 ISO 9906 Grade 2
400
120
/457.2
360
/431.8
100
320
/406.4
280
80
/381.0
240
60 200
NPSH
[ft] [m]
160 80
40 20
120 60
15
80 40
20 10
40 20
5
NPSH
0 0 0 0
0 100 200 300 400 500 600 700 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
400 80
350 /482.6 70
250
/381.0 /406.4 /431.8 /457.2
300 60
200 /482.6
250 50
/457.2
150 200 40
/431.8
150 /406.4 30
100
/381.0
100 20
50
50 10
0 0 0
0 100 200 300 400 500 600 700 Q [m³/h]
TM05 7552 1113
The grey line represents a maximum shaft load of 7.25 kW/100 rpm for a ∅44.5 (1.75 inch) pump shaft when pumping
water. If the required shaft load exceeds 7.25 kW/100 rpm, use a pump with a ∅50.8 (2 inch) pump shaft.
Be aware that the curves will change when pumping liquids with a higher density and/or viscosity than water.
61
12
Performance curves-technical data
Dimensional sketch
HS standard, 200-150-483
62
12
H H
[m] [ft]
/508.0
HS 200-150-508
480
60 Hz, n = 1780 min-1
140 ISO 9906 Grade 2
440
/469.9
400
120
360 /431.8
100
320
/393.7
280
80
240 /355.6
60 200
160
NPSH
[ft] [m]
40
120 60
15
80 40
20 10
NPSH
40 20
5
0 0 0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
800 80
300 /431.8 30
200
/393.7
200 20
/355.6
100
100 10
0 0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
TM05 7553 1113
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
63
12
Performance curves-technical data
Dimensional sketch
HS standard, 200-150-508
64
12
H H
[m] [ft]
170 HS 250-200-305
50 /304.8 60 Hz, n = 1780 min-1
160
ISO 9906 Grade 2
150
45
140
/273.1
40 130
120
35
110
/241.3
30 100
90
25 /209.6
80
70
20
60
/177.8
50 NPSH
15
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
NPSH 4
10 10
2
0 0 0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
180 90
120 160 /304.8 80
/273.1
100 140 70
/241.3
/209.6
120 /304.8 60
80 /177.8
100 50
/273.1
60 80 40
60 30
40 /241.3
40 /209.6 20
20
20 /177.8 10
0 0 0
0 100 200 300 400 500 600 700 800 900 Q [m³/h]
TM05 7554 1113
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
65
12
Performance curves-technical data
Dimensional sketch
HS standard, 250-200-305
66
12
H H
[m] [ft]
80
HS 250-200-381
260 /381.0
60 Hz, n = 1780 min-1
ISO 9906 Grade 2
240
70
220
/342.9
200
60
180
50 /304.8
160
140
40 /266.7
120
30 100 /228.6
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
450 90
300 400 80
/342.9 /381.0
250 350 /304.8 70
/266.7
300 /381.0 60
200 /228.6
250 50
/342.9
150 200 40
150 /304.8 30
100
100 /266.7 20
50
50 /228.6 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 Q [m³/h]
TM05 7555 1113
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500Q [US GPM]
67
12
Performance curves-technical data
Dimensional sketch
HS standard, 250-200-381
68
12
H H
[m] [ft]
440
/489.0 HS 300-200-489
130
420 60 Hz, n = 1780 min-1
400 ISO 9906 Grade 2
120
380
/455.7
110 360
340
100
320 /422.1
90 300
280
/388.9
80 260
240
70 /355.6
220
60 200
180
50 160
140
40
120
NPSH
30 100 [ft] [m]
80 80
20 20
60 60
15
40 40
10 10
20 NPSH 20 5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
1800 90
1200 1600 80
/489.0
/422.1 /455.7
1000 1400 /388.9 70
/355.6
1200 60
800
1000 50
600 800 40
/489.0
600 /455.7 30
400
/422.1
400 20
/388.9
200 /355.6
200 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 Q [m³/h]
TM05 7538 1113
0 800 1600 2400 3200 4000 4800 5600 6400 7200 Q [US GPM]
69
12
Performance curves-technical data
70
12
H H
[m] [ft]
170 HS 300-250-305
50
/304.8
60 Hz, n = 1780 min-1
160
ISO 9906 Grade 2
150
45
140
/279.4
40 130
120
35
110 /254.0
30 100
/235.0
90
25
80
/209.6
70
20
60
15 50
40
NPSH
[ft] [m]
10
30 60
15
20 40
5 10
10 NPSH 20 5
0 0 0 0
0 200 400 600 800 1000 1200 1400 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
360 90
240 320 80
200 280 70
/254.0 /279.4 /304.8
/235.0
240 60
160
200 /209.6 50
0 0 0
0 200 400 600 800 1000 1200 1400 Q [m³/h]
TM05 7539 1113
71
12
Performance curves-technical data
Dimensional sketch
HS standard, 300-250-305
72
12
H H
[m] [ft]
280
HS 300-250-381
60 Hz, n = 1780 min-1
/390.4
80 260 ISO 9906 Grade 2
240
70
/355.5
220
60 200
/330.2
180
50
160 /304.7
140
40 /279.4
120
30 100
80 NPSH
[ft] [m]
20
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
/390.4
700 /355.5 70
500 /330.2
/304.7
600 60
400 /279.4
500 50
300 /390.4
400 40
300 /355.5 30
200
200 /330.2 20
100 /304.7
100 /279.4 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 Q [m³/h]
TM05 7540 1113
73
12
Performance curves-technical data
Dimensional sketch
HS standard, 300-250-381
74
12
H H
[m] [ft]
HS 350-250-498
480
60 Hz, n = 1780 min-1
140 ISO 9906 Grade 2
440 /497.8
400
120
/463.6
360
100 /425.5
320
280
/391.2 NPSH
80 [ft] [m]
240 120
/355.6 35
60 200 100 30
160 80 25
40 20
120 60
15
80 40
20 10
NPSH
40 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
1600 90
1400 80
1000 /463.6 /497.8
/391.2 /425.5
1200 70
800 /355.6
1000 /497.8 60
600 800 50
/463.6
600 /425.5 40
400
/391.2
400 30
/355.6
200
200 20
0 0 10
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 Q [m³/h]
TM05 7541 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 Q [US GPM]
75
12
Performance curves-technical data
Dimensional sketch
HS extended, 350-250-498
76
12
H H
[m] [ft]
750
/629.9 HS 350-250-630
220 60 Hz, n = 1780 min-1
700 ISO 9906 Grade 2
200 650
/584.2
600
180
550
160 /533.4
500
140
450
/482.6
120 400
350 /431.8
100
300
80
250 NPSH
[ft] [m]
60 200 80
20
150 60
40 15
100 40
10
20
50 NPSH 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
3600 90
2400 3200 80
2000 2800 70
/584.2 /629.9
/482.6 /533.4
2400 /431.8 60
1600
2000 /629.9 50
1200 1600 40
/584.2
1200 30
800 /533.4
800 /482.6 20
400 /431.8
400 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [m³/h]
TM05 7542 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
77
12
Performance curves-technical data
Dimensional sketch
HS extended, 350-250-630
78
12
H H
[m] [ft]
280
HS 400-350-397
/396.2 60 Hz, n = 1780 min-1
80 260 ISO 9906 Grade 2
/374.7
240
70
220
/349.3
60 200
/330.2
180
50 /304.8
160
140
40
120
30 100 NPSH
[ft] [m]
80 80
20 20
60 60
15
40 40
NPSH
10 10
20 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
700 70
500 /374.7 /396.2
600 /304.8 /330.2 /349.3 60
400
500 50
300 400 40
/396.2
/374.7
300 30
200 /349.3
/330.2
200 /304.8 20
100
100 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 3000Q [m³/h]
TM05 7543 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 12000 Q [US GPM]
79
12
Performance curves-technical data
Dimensional sketch
HS extended, 400-350-397
80
12
H H
[m] [ft]
190 HS 200-150-483
/482.6
55 180 60 Hz, n = 1180 min-1
ISO 9906 Grade 2
170
/457.2
50
160
150 /431.8
45
140
40 /406.4
130
120
35 /381.0
110
30 100
90
25 80
70
20
60
NPSH
15 50
[ft] [m]
40 40 12
10 10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 50 100 150 200 250 300 350 400 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
160 80
140 70
100 /457.2 /482.6
/381.0 /406.4 /431.8
120 60
80
100 50
60 80 /482.6 40
/457.2
60 /431.8 30
40
/406.4
40 20
/381.0
20
20 10
0 0 0
0 50 100 150 200 250 300 350 400 Q [m³/h]
TM05 7544 1113
0 200 400 600 800 1000 1200 1400 1600 1800 Q [US GPM]
81
12
Performance curves-technical data
Dimensional sketch
HS extended, 200-150-483
82
12
H H
[m] [ft]
70 HS 200-150-508
220 60 Hz, n = 1180 min-1
/508.0
ISO 9906 Grade 2
200
60
/469.9
180
50
160
/431.8
140
40 /393.7
120
/355.6
30 100
80
NPSH
20
[ft] [m]
60 30
8
40 20 6
10
NPSH 4
20 10
2
0 0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
320 80
280 70
200 /508.0
/431.8 /469.9
240 /393.7 60
/355.6
160
200 50
120 160 40
/508.0
120 /469.9 30
80
80 /431.8 20
/393.7
40 /355.6
40 10
0 0 0
0 50 100 150 200 250 300 350 400 450 500 550 600 Q [m³/h]
TM05 7545 1113
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 Q [US GPM]
83
12
Performance curves-technical data
Dimensional sketch
HS extended, 200-150-508
84
12
H H
[m] [ft]
HS 250-200-381
120
60 Hz, n = 1180 min-1
35 /381.0 ISO 9906 Grade 2
110
100
30
/342.9
90
25
80
70 /304.8
20
60
/266.7
15 50
NPSH
[ft] [m]
/228.6
40 20 6
10
30 15
4
20 10
5
2
NPSH
10 5
0 0 0 0
0 100 200 300 400 500 600 700 800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
180 90
120 160 80
/342.9 /381.0
100 140 /304.8 70
/266.7
120 60
80 /228.6
100 50
/381.0
60 80 40
60 /342.9 30
40
40 /304.8 20
20 /266.7
20 /228.6 10
0 0 0
0 100 200 300 400 500 600 700 800 Q [m³/h]
TM05 7546 1113
85
12
Performance curves-technical data
Dimensional sketch
HS extended, 250-200-381
86
12
H H
[m] [ft]
HS 300-200-489
200 60 Hz, n = 1180 min-1
60
ISO 9906 Grade 2
/489.0
180
50 /455.7
160
140 /422.1
40
120 /388.9
100 /355.6
30
80
NPSH
20
[ft] [m]
60 30
8
40 20 6
10
4
20 10
NPSH 2
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
400 90
350 80
250 /489.0
/422.1 /455.7
300 /388.9 70
200 /355.6
250 60
0 0 10
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
TM05 7529 1113
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
87
12
Performance curves-technical data
Dimensional sketch
HS extended, 300-200-489
88
12
H H
[m] [ft]
75
HS 300-250-305
22 60 Hz, n = 1180 min-1
/304.8
70 ISO 9906 Grade 2
20 65
60 /279.4
18
55
16
50
/254.0
14
45
/235.0
12 40
35
10 /209.6
30 NPSH
[ft] [m]
8
25 25
7
6 20 20 6
5
15 15
4 4
10 10 3
NPSH
2 2
5 5
1
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
90 90
60 80 80
30 /254.0 30
20
20 /235.0 20
10 /209.6
10 10
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 Q [m³/h]
TM05 7530 1113
0 500 1000 1500 2000 2500 3000 3500 4000 Q [US GPM]
89
12
Performance curves-technical data
Dimensional sketch
HS extended, 300-250-305
90
12
H H
[m] [ft]
HS 300-250-381
120
/390.4
60 Hz, n = 1180 min-1
35 ISO 9906 Grade 2
110
100 /355.5
30
90
25 /330.2
80
70 /304.7
20
60 /279.4
15 50
40
NPSH
[ft] [m]
10
30 30
8
20 20 6
5
4
10 10
NPSH 2
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
360 90
240 320 80
/390.4
280 /355.5 70
200 /330.2
/304.7
240 60
160 /279.4
200 50
120 160 40
120 /390.4 30
80
/355.5
80 20
40 /330.2
40 /304.7 10
/279.4
0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 Q [m³/h]
TM05 7531 1113
0 400 800 1200 1600 2000 2400 2800 3200 3600 4000 4400 Q [US GPM]
91
12
Performance curves-technical data
Dimensional sketch
HS extended, 300-250-381
92
12
H H
[m] [ft]
HS 350-250-498
200 60 Hz, n = 1180 min-1
60 /497.8 ISO 9906 Grade 2
180
/463.6
50
160
140 /425.5
40
120 /391.2
30 100 /355.6
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 20
5
NPSH
0 0 0 0
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
400 90
350 80
250 /463.6 /497.8
/391.2 /425.5
300 70
/497.8
200 /355.6
250 60
/463.6
150 200 50
/425.5
150 40
100 /391.2
100 /355.6 30
50
50 20
0 0 10
0 100 200 300 400 500 600 700 800 900 1000 1100 1200 1300 1400 1500 1600 1700 Q [m³/h]
TM05 7532 1113
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000 6500 7000 Q [US GPM]
93
12
Performance curves-technical data
Dimensional sketch
HS extended, 350-250-498
94
12
H H
[m] [ft]
340 /629.9 HS 350-250-630
100 60 Hz, n = 1180 min-1
320
ISO 9906 Grade 2
300
90
/584.2
280
80 260
240
/533.4
70
220
60 200
/482.6
180
50
160
/431.8
140
40
120
30 100
80
NPSH
[ft] [m]
20
60 30
8
40 20 6
10
4
20 NPSH 10
2
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
500 700 70
/584.2 /629.9
/482.6 /533.4
600 /431.8 /629.9 60
400
500 50
/584.2
300 400 40
/533.4
300 30
200
/482.6
200 20
100 /431.8
100 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
TM05 7533 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
95
12
Performance curves-technical data
Dimensional sketch
HS extended, 350-250-630
96
12
H H
[m] [ft]
70 HS 350-300-508
220 60 Hz, n = 1180 min-1
/508.0 ISO 9906 Grade 2
200
60
180
/463.6
50
160
140 /419.1
40
120
/374.7
30 100
/330.2
80
NPSH
20
[ft] [m]
60 60
15
40 40
10 10
20 NPSH 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
900 90
600 800 80
500 700 70
/419.1 /463.6 /508.0
600 /374.7 60
/330.2
400
500 50
300 /508.0
400 40
300 /463.6 30
200
200 /419.1 20
100 /374.7
100 /330.2 10
0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 2000 2200 2400 2600 2800 Q [m³/h]
TM05 7534 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 9000 10000 11000 Q [US GPM]
97
12
Performance curves-technical data
Dimensional sketch
HS extended, 350-300-508
98
12
H H
[m] [ft]
HS 400-350-397
120 /396.2
60 Hz, n = 1180 min-1
35 ISO 9906 Grade 2
110
/374.7
100
30
/349.3
90
/330.2
25
80
/304.8
70
20
60
15 50
40
NPSH
[ft] [m]
10
30 60
15
20 40
5 10
10 NPSH 20
5
0 0 0 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
P2 P2 Eff
[kW] [hp] [%]
200 90
140
180 80
120 160 70
/304.8 /374.7 /396.2
/330.2
140 /349.3 60
100
120 50
80 /396.2
100 40
/374.7
60 80 /349.3 30
/330.2
60 20
40 /304.8
40 10
20
20 0
0 200 400 600 800 1000 1200 1400 1600 1800 Q [m³/h]
TM05 7535 1113
0 1000 2000 3000 4000 5000 6000 7000 8000 Q [US GPM]
99
12
Performance curves-technical data
Dimensional sketch
HS extended, 400-350-397
100
This doctitle must be changed on the front
13
Electrical data
The standard motor brand used for the entire HS pump range is Grundfos type MMG-G IE2 motors. Other makes and
voltage variants are available on request.
2-pole motors
Motor P2 Standard voltage I 1/1
Cos ϕ 1/1 η Istart/I1/1
Frame size
[kW] [V] [A] [%] [%]
18.5 MMG-G 160L 380-480 D/660-690 Y 33.5-26.5/19.2-18.4 0.92-0.90 91.4-93.2 840
22 MMG-G 180MA 380-480 D/660-690 Y 40.0-34.0/23.0-24.0 0.90-0.83 92.6-93.5 860
30 MMG-G 200LA 380-480 D/660-690 Y 56.0-44.5/32.5-31.0 0.88-0.86 92.2-93.6 860
37 MMG-G 200LA 380-480 D/660-690 Y 67.0-52.5/38.5-36.5 0.89 93.8-95 860
45 MMG-G 225MA 380-480 D/660-690 Y 78.5-63.0/45.0-44.0 0.94-0.91 93.3-94.3 840
55 MMG-G 250SA 380-480 D/660-690 Y 95.5-76.5/55.0-53.0 0.93-0.92 94.0 740
75 MMG-G 250MA 380-480 D/660-690 Y 128-102/73.5-71.5 0.94-0.93 94.6 750
90 MMG-G 280SA 380-480 D/660-690 Y 154-124/88.0-85.5 0.94-0.93 95.0 700
110 MMG-G 280MA 380-480 D/660-690 Y 190-150/108-104 0.93 95.5 760
4-pole motors
Motor P2 Standard voltage I 1/1
Cos ϕ 1/1 η Istart/I1/1
Frame size
[kW] [V] [A] [%] [%]
2.2 MMG-G 100L 220-277 D/380-480 Y 7.80-6.30/4.50-3.65 0.85-0.83 87.2-87.9 760-960
3 MMG-G 100L 380-480 D/660-690 Y 6.25-5.05/3.60-3.50 0.83-0.81 87.7-88.4 980
3.7 MMG-G 112M 380-480 D/660-690 Y 7.45-6.00/4.30-4.15 0.85-0.83 89.2-89.9 980
4 MMG-G 112M 380-480 D/660-690 Y 8.05-6.45/4.60-4.50 0.85-0.83 89.2-89.9 980
5.5 MMG-G 132S 380-480 D/660-690 Y 10.8-8.50/6.20-5.95 0.86-0.85 90.6-91.5 980
7.5 MMG-G 132M 380-480 D/660-690 Y 14.4-11.6/8.35-8.10 0.87-0.85 90.7-91.5 870
11 MMG-G 160M 380-480 D/660-690 Y 20.6-16.4/11.6-11.4 0.89-0.87 92.7-93.5 870
15 MMG-G 160L 380-480 D/660-690 Y 27.0-22.0/15.6-15.2 0.90-0.88 93.2-94.0 860
18.5 MMG-G 180MC 380-480 D/660-690 Y 34.5-28.0/19.8-19.4 0.87-0.85 93.7-94.5 880
22 MMG-G 180LC 380-480 D/660-690 Y 41.0-33.0/23.6-23.0 0.87-0.85 93.7-94.5 830
30 MMG-G 200LC 380-480 D/660-690 Y 54.0-43.5/31.0-30.5 0.89-0.87 94.2-95.0 930
37 MMG-G 225SC 380-480 D/660-690 Y 68.5-55.0/39.5-38.5 0.87-0.85 94.7-95.5 780
45 MMG-G 225MC 380-480 D/660-690 Y 82.5-66.5/47.5-46.5 0.87-0.85 94.7-95.5 740
55 MMG-G 250SC 380-480 D/660-690 Y 104-80.0/60.0-55.5 0.85-0.86 94.9-96.0 740
75 MMG-G 250MC 380-480 D/660-690 Y 142-110/81.5-76.0 0.85-0.86 94.7-96.0 730
90 MMG-G 280SB 380-480 D/660-690 Y 170-130/97.5-91.0 0.85-0.86 95.0-96.0 700
110 MMG-G 280MB 380-480 D/660-690 Y 206-160/120-112 0.85-0.86 95.5-96.0 680
132 MMG-G 315SB 380-480 D/660-690 Y 250-190/142-132 0.85-0.87 95.1-96.0 600
160 MMG-G 315MB 380-480 D/660-690 Y 300-230/172-160 0.86-0.87 95.1-96.0 600
200 MMG-G 315MB 380-480 D/660-690 Y 365-290/210-166 0.88 95.8 780
250 MMG-G 315CB 380-480 D/660-690 Y 455-355/260-246 0.89 94.5-95.2 550-830
315 MMG-G 315DB 380-480 D/660-690 Y 575-445/330-310 0.88-0.90 94.5-95.2 550-830
335 MMG-G 315DB 380-480 D/660-690 Y 610-470/350-330 0.88-0.90 94.5-95.3 550-830
355 MMG-G 355AB 380-480 D/660-690 Y 645-510/370-355 0.89-0.88 94.5-95.2 550-830
375 MMG-G 355AB 380-480 D/660-690 Y 680-540/390-375 0.89-0.88 94.5-95.3 550-830
400 MMG-G 355CB 380-480 D/660-690 Y 730-570/420-395 0.88-0.89 94.7-95.3 550-830
450 MMG-G 355CB 380-480 D/660-690 Y 820-640/470-445 0.88-0.89 94.7-95.5 550-830
500 MMG-G 400AB 380-480 D/660-690 Y 890-700/515-485 0.90 94.7-95.5 550-830
525 MMG-G 400AB 380-480 D/660-690 Y 935-735/540-510 0.90 94.7-95.6 550-830
560 MMG-G 400CB 380-480 D/660-690 Y 995-785/575-545 0.90 94.8-95.6 550-830
600 MMG-G 400CB 380-480 D/660-690 Y 1060-840/615-585 0.90 94.8-95.7 550-830
101
13 This doctitle must be changed on the front
6-pole motors
Electrical data
102
HS
14
Dimensional sketch
103
14 HS
Dimensions
Bare shaft pump
All dimensions are in mm, except for those which have necessary inch tolerances (1 inch = 25.4 mm).
For actual pump flange dimensions, see “Standard pump flange dimensions” on page 105. For counter-flange
dimensions, “Counter-flange dimensions” on page 107.
CP Key (WxL)
Pump size DNs DNd A AE B BP D DH G ∅ HH HZ
Sealed Packed [inch] [mm]
HS 65-50-242 65 50 305 260 222 178 510 545 178 89 16 19 270 0.25x2.12 6.35x53.85
HS 65-50-331 65 50 305 260 222 178 510 545 216 89 16 19 355 0.25x2.12 6.35x53.85
HS 100-80-242 100 80 305 260 222 178 510 545 203 102 19 19 290 0.25x2.12 6.35x53.85
HS 100-80-356 100 80 305 260 279 235 644 687 254 127 22 19 380 0.38x2.25 9.65x57.15
HS 125-100-280 125 100 305 260 283 235 631 674 257 124 22 19 370 0.38x2.25 9.65x57.15
HS 125-100-305 125 100 305 260 283 235 631 674 257 124 22 19 370 0.38x2.25 9.65x57.15
HS 125-100-388 125 100 305 260 349 305 631 674 330 159 25 19 470 0.38x2.25 9.65x57.15
HS 150-125-305 150 125 305 260 305 260 775 775 368 165 25 19 475 0.38x2.25 9.65x57.15
HS 150-125-381 150 125 305 260 305 260 801 801 410 165 25 19 550 0.38x2.25 9.65x57.15
HS 200-150-305C 200 150 305 260 305 260 801 801 406 165 25 19 530 0.38x2.25 9.65x57.15
HS 200-150-381 200 150 311 260 457 419 929 929 464 184 29 19 605 0.38x2.25 9.65x57.15
HS 200-150-483 2) 200 150 305 260 356 305 888 888 432 171 25 19 615 0.38x2.31 9.65x57.74
HS 200-150-483 3) 200 150 305 260 356 305 899 899 432 171 25 19 615 0.38x3.00 9.65x76.20
HS 200-150-508 200 150 318 260 356 305 995 995 451 171 25 19 660 0.50x3.00 12.70x76.20
HS 250-200-305 250 200 305 260 394 356 929 929 438 171 29 19 580 0.38x2.25 9.65x57.15
HS 250-200-381 250 200 324 260 495 445 949 949 483 178 29 19 655 0.38x2.25 9.65x57.15
HS 300-200-489 300 200 648 502 489 406 1306 1306 529 198 35 29 745 0.63x3.00 16.00x76.20
HS 300-250-305 300 250 324 260 495 445 974 974 503 203 29 19 645 0.38x2.25 9.65x57.15
HS 300-250-381 300 250 457 381 356 305 1051 1051 508 254 29 22 630 0.50x2.75 12.70x69.85
HS 350-250-498 350 250 648 502 489 406 1403 1403 586 246 35 29 785 0.75x4.75 19.05x120.65
HS 350-250-630 350 250 648 502 489 406 1377 1377 635 305 35 29 820 0.75x4.75 19.05x120.65
HS 350-300-508 350 300 648 502 489 406 1377 1377 643 313 35 29 790 0.63x3.00 16.00x76.20
HS 400-350-397 400 350 790 610 657 575 1299 1299 670 320 40 23 800 0.63x3.00 16.00x76.20
N U Net weight
Pump size DNs DNd SH W WB WS X YY
Sealed Packed [inch] [mm] [kg]
HS 65-50-242 65 50 100 65 88.9 1.00 25.40 305 416 216 216 216 73
HS 65-50-331 65 50 100 65 88.9 1.00 25.40 305 416 216 254 254 95
HS 100-80-242 100 80 100 65 102 1.00/1.19 1) 52.40/30.16 1) 305 416 216 279 279 80
HS 100-80-356 100 80 118 75 127 1.50 38.10 368 508 251 305 305 177
HS 125-100-280 125 100 106 63 124 1.50 38.10 368 508 251 305 305 164
HS 125-100-305 125 100 106 63 124 1.50 38.10 368 508 251 305 305 164
HS 125-100-388 125 100 106 63 159 1.50 38.10 368 543 216 357 357 255
HS 150-125-305 150 125 63 63 165 1.50 38.10 419 572 289 330 330 268
HS 150-125-381 150 125 63 63 165 1.50 38.10 432 584 302 356 381 318
HS 200-150-305C 200 150 63 63 165 1.50 38.10 432 584 302 356 406 411
HS 200-150-381 200 150 87 87 184 1.75 44.45 508 737 298 381 406 455
HS 200-150-483 2) 200 150 90 90 171 1.75 44.45 489 667 337 432 432 534
HS 200-150-483 3) 200 150 85 85 171 2.00 50.80 489 667 337 432 432 534
HS 200-150-508 200 150 98 98 171 2.13 53.98 546 724 394 432 483 545
HS 250-200-305 250 200 87 87 171 1.75 44.45 508 705 330 406 432 511
HS 250-200-381 250 200 87 87 178 1.75 44.45 518 765 295 483 483 568
HS 300-200-489 300 200 147 147 198 2.50 63.50 723 994 519 414 559 727
HS 300-250-305 300 250 87 87 203 1.75 44.45 530 778 308 495 495 636
HS 300-250-381 300 250 149 149 254 2.25 57.15 600 778 448 432 584 991
HS 350-250-498 350 250 205 205 246 3.13 79.38 797 1049 594 508 660 1436
HS 350-250-630 350 250 219 219 305 3.13 79.38 799 1049 594 610 711 1905
HS 350-300-508 350 300 121 121 313 2.50 63.50 749 994 546 584 711 1318
HS 400-350-397 400 350 142 147 320 2.50 63.50 723 1052 436 550 650 1460
1)
Depending of the shaft load
2) Shaft load up to 7.25 kW/100 rpm
3)
Shaft load above 7.25 kW/100 rpm.
104
HS
14
Standard pump flange dimensions
105
14 HS
PN 10
Some pump flanges have tapped holes due to the pump construction.
106
HS
14
Counter-flange dimensions
D2 125 145 160 180 210 240 295 355 410 470 525
TM02 7720 3803
D3 165 185 200 220 250 285 340 400 455 520 580
D2
D3 S 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 12 x 23 12 x 28 12 x 28 16 x 28 16 x 31
Bolt size M16 M16 M16 M16 M16 M20 M20 M24 M24 M24 M27
D2 125 145 160 180 210 240 295 350 400 460 515
TM02 7720 3803
D3 165 185 200 220 250 285 340 395 445 505 565
D2
D3 S 4 x 19 4 x 19 8 x 19 8 x 19 8 x 19 8 x 23 8 x 23 12 x 23 12 x 23 16 x 23 16 x 28
Bolt size M16 M16 M16 M16 M16 M20 M20 M20 M20 M20 M24
107
15 HS
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
220,000 Grundfos products in more than 20
languages.
In WebCAPS, all information is divided into 6 sections:
• Catalogue
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalogue
Literature
In this section you can access all the latest documents of a given
pump, such as
• data booklets
• Installation and operating instructions
• service documentation, such as Service kit catalogue and
Service kit instructions
• quick guides
• product brochures, etc.
Service
108
HS
15
Replacement
CAD drawings
2-dimensional drawings
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.
WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed
informtion on more than 185,000 Grundfos products in
more than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.
Fig. 36 WinCAPS CD-ROM
109
110
111
ECM: 1109069
98435966 0413
GRUNDFOS A/S
www.grundfos.com
Telephone: +45 87 50 14 00
DK-8850 Bjerringbro . Denmark