Operation Manual

HD-F735
Chair Arm AND LEG DURABILITY Tester
(Doc Version: HD-F735-M001)

Thanks for using our product and please carefully read this manual before using

P 1 f www.haidatestequipment.com
Operation Manual

Preface

Thanks for choosing our company products, and also the high quality and good service will be
provided in time.
In order to ensure the safety of the user and the integrity of the machine, please read the operate
instruction carefully before using the equipment, and pay more attention to the using notes. This
operation manual will introduce the design principles, design criteria, structure, operating norms,
calibration, maintenance, some failure case and solutions, electrical diagrams and so on. If this
operation and manual in reference to various “test requirement”, “standard”, all of them just for
your reference.
Please review relevant standards or data by yourself if you feel there is disagreement.

Special Statement
● This operating manual can’t be basis as serve as any request to our company.
● The interpretation of this manual in our company.

HAIDA INTERNATIONAL EQUIPMENT CO.,LTD.

Phone: +86-769-89055588
Email: Support 02@qc-test.com
Website: www.haidatestequipment.com

Page 1 of 16
Operation Manual

Directory

Overview 5

Designed Standard 6

Equipment Instruction 6

Equipment Operation 8

Maintenance 15

Quality Assurance 16

Notes 17

Page 3 of 16
!!
Danger: Warning sign This mark indicates the need to reference manual.
This show that if failure to comply, the operator may be harmed.
Attention of Security
Dangerous voltage
This mark indicates danger high voltage.
symbol
1, Security marks
There are some safety precaution and important notes when using the equipment, in order to
Ground protection
prevent accidents and dangerous, please observe the following narration of danger, warning and
note. This show the ground terminal of the instrument.
mark

Warning:
! This show that if failure to comply, it may damage the equipment.

Attention:
This show that the project may effect the test result and quality.

Note:
This project show that auxiliary stated in the operation.

2, In this instrument, the following signs show attention and warning:

Overview

1.Usage
This machine is simulated in daily use conditions, testing the chair to long-term repetitive load
bearing capacity. The durability test chair armchair foot, the test will be a certain shape, quality of
the loading module, in the specified loading form, frequency, respectively arm, chair foot repeated
loading, this test in order to improve the product at any time, eliminate potential quality
problems, improve the durability and reliability of the product.

2.Function:
Arm and leg durability tester is suitable for office chair and other furniture products, determine
the ability of chair armrest structure to withstand vertical pressure and 10° Angle side pressure to

Page 2 of 17
withstand deformation and chair foot strength test, test the durability of chair armrest and chair
foot structure, improve the quality of products.

3.Principle
1.Arm test: he armrest chair is placed on the floor, using a fixed and rotating fixture should be
fixed, adjust the armrest Angle of 10 °, adjust the height of the ball screw to make it to the right,
about manual regulation set up fingerprint, allow it to get stuck armrest, began testing armrest,
through the armrest of deformation degree, structure durability of the chair.

Chair foot strength test: the sample chair is placed on the bottom plate, fixed and anti-rotation
fixture will be fixed, manually adjust the cylinder module to the appropriate height, apply a certain
force value, through the deformation degree of the chair foot, understand the structural strength
of the chair foot.

Designed Standard
The instrument cited standards: BIFMA5.1-2017 EN1728-2012 EN133 etc.

Equipment Instruction
Structure (Figure 1)

Page 2 of 17
Fig 1
Control Panel
State
Power switch: Main switch of machine power supply
Emergency stop button: When the machine needs
to stop if encountering abnormal conditions in
operation, this key can make the machine stop
instantly

Parameter

Item parameter

Control mode PLC

Display Touch Screen

Capacity 1kNL load sensor*1 Leg 2kN Load sensor*2 Arm

Arm Height Scope 500 750mm

Left right limit 400 1100mm

Speed 10 30 cycles/min

Angle 10°

Distance of Shaft and Arm 600±10mm

Are durability test 440N

Test force Front seat Alternating durability test 890N

Leg strength test 334N

Page 2 of 17
Danger!
■ voltage error range is ±10%.please sure the machine is
Weight
! About 450kg
earthed correct to prevent the machine leakage

Power 1 AC 220V About 150W

Data USB Output

Test Space 1300mmx1250mmx1500mm L*W*H

Dimension 2150mmx1300mmx2000mm L*W*H

Arm durability test,Arm vertical static test,Arm horizontal static,Leg strength test
Test Item
,Seat edge alternating durability test

Equipment Installation
1. Power: Please connect correct power according to nameplate

2. Environment requirement during operation:


Room Temperature from 0-55 ;Relative Humility less than 80% RH;
Far away from severe electromagnetic interference.

3. Instrument should be place on the level surface.

Equipment Operation
Preparation Before Test
1) Place the instrument on the ground link Electricity and gas ,put the sample on the
platform Turn the pressure regulator Adjust the air pressure in the green area 0.5~0.6MP

Page 2 of 17
2) Select samples fixed in the test frame.
3) Manually turn the adjusting handle, test the height of the component, manually turn the hand
wheel, and adjust the Angle and distance of the corresponding test component separately.

Width of left and right


adjustment

Fig 3
Operating steps
1)After connecting power supply, open the power switch, control interface into main interface (
interface 1).

Page 2 of 17
(interface 1)
In interface 1, choose Chinese and English. Click “start” into the main menu interface (as below
interface 2); According to the test requirement of the tested sample, to choose the corresponding
test method.

( interface 2)
AB Group: Enter the interface of AB Group Test
CD Croup: Enter the interface of CD Group Test
Parameter Setting: Enter the interface of parameter setting
Manual operation: Enter the interface of manual operation
Force value calibration: Enter the interface of force value calibration
Alarm: Enter the interface of alarm

Click “Manual” enter into the (interface 3), fix the test items on the test stand, according to the
need, the position of each test head is adjusted by manual "forward, backward, up and down". Fix
Page 2 of 17
it after adjusting to meet the test requirements.
Use tip: before use, please adjustment according to the tested product height, width and
Angle; This adjustment please refer to the width and Angle in (interface 3) on the map indicates,
Height within the (interface 3) the "manual" to do adjust up and down.

(interface 3)
If force limit is required, select the "Parameter Setting" key in interface 3 to enter interface 4.
“Count Zero” any single set of force values; After clearing, click the corresponding test item of the
corresponding group to set the force limit according to the test needs. When the pneumatic
device applies force to the sample, each force value display box will display the pressure of the
test sample.

Page 2 of 17
( interface 4)
Detection sensitivity: For damage detection, example: sensitivity set 30%, test force value is 500N,
during the test, the equipment in the holding state, the force value suddenly drops below 30%
of the set force value, that is, below 150N, the equipment immediately stop testing, the
system determines the sample damage.
Coefficient: used to control the initial thrust of cylinder module during testing. This parameter has
been adjusted to an appropriate value before leaving the factory. If you need to change this
parameter, you only need to fine tune it. If the initial force is smaller than the set force,
increase the value. If the initial force is greater than the set force, the value can be reduced
Backward: The time required for the cylinder to return to its original position;
Force limit: For the protection of force sensor Settings, please do not easily change, in order to
avoid damage to the machine.
Force PV: Real-time force value of sensor.
Force Zero: The force value is cleared before the test to ensure the accuracy of the test data
Manual operation: Enter the interface of manual operation
AB group: Enter the interface of AB Group test
CD group: Enter the interface of CD group test
Menu: Enter the interface of main menu

When manual operation and force value adjustment are completed, click the Menu to return to
the interface (2) Click Group AB to enter the interface (5). Set the parameters of left and right
handrails respectively according to prompts, and set the cycles, A/B force value, hold time, A/B
return time, Rest time and other parameters in turn. After setting, click the count Zero button to
clear historical test data to ensure the accuracy of test data. Then click the start button to start the
test. If there is any abnormality during the test, press the stop button on the controller (or press
the emergency stop button) to stop the test.

Page 2 of 17
( interface 5)
Cycles(PV/SV) Current measured cycles/setting cycles
Force Current force value/setting target force value;
Hold time Current force value holding time/ setting holding time
Return time Current return timing / setting return time
Rest time Looping time/setting loop time (loop time: the time between the end of a test cycle and
the start of the next test);

NOTE If you only need to test the left and right handrails separately, click the corresponding
boxes of group A and Group B; If you need to test left and right handrails alternately, click
alternating A and B keys; To test the left and right handrails at the same time, click A and B at
the same time; If the test group is displayed in green, the test group is selected; if the test group
is displayed in gray, the test group is not performed.

When manual operation and force value adjustment are completed, click the Menu to return to
the interface (2) Click Group C to enter the interface (6). Set the parameters of left and right
handrails respectively according to prompts, and set the cycles, A/B force value, hold time, A/B
return time, Rest time and other parameters in turn. After setting, click the count Zero button to
clear historical test data to ensure the accuracy of test data. Then click the start button to start the
test. If there is any abnormality during the test, press the stop button on the controller (or press
the emergency stop button) to stop the test.

Page 2 of 17
(interface 6)

Cycles(PV/SV) Current measured cycles/setting cycles


Force Current force value/setting target force value;
Hold time Current force value holding time/ setting holding time
Return time Current return timing / setting return time
Rest time Looping time/setting loop time (loop time: the time between the end of a test cycle and
the start of the next test);

Click the key of "Force Calibration" in interface (6) to enter the interface of setting force value (as
shown in Figure 7).

*NOTICE!!!
The machine has been professionally calibrated before leaving the factory, the
user receives the machine without needing to calibrate again! Data misalignment
caused by arbitrary adjustment of calibration data is not within the scope of free
calibration service, and the cost of returning to the factory shall be borne by buyer
themselves.

Page 2 of 17
(interface 7)

Select different test methods to test the samples, and the machine will stop automatically after
reaching the set number of times;
According to the above steps 1-6 can be used to test different samples, and record the test sample
status.

Note:
Test two sets, the air pressure must ensure that the above 0.6 Mpa, otherwise it will caused test
can not be normal by insufficient pressure.
Set the test force value cannot exceed the standard force.
Use after a period of time, please check whether screw loose.
Speed can be set by the parameter of back time and testing interface of the hold time and cycle
time to adjust, set up time is smaller, the speed faster, on the other hand, will be slow.
Pls after-sales consulting of indicate the details or actual operating abnormal.

Maintenance

Clean: Keep the machine clean. Every time please wipe out the machine with cotton cloth to keep
it clean after finishing test.
Rust Resistance: spray corrosive oil on the surface of the machine every week(wipe out after 2
hours)
lubricating oil: add lubricating oil to machine drive part (such as screw)

Page 2 of 17
Quality Assurance
Quality Assurance Items
The guarantee period is one year (consumer goods and travel cost are not included)
The main quality warranty maintenance certificate
1). Please keep this guarantee letter, if you lost it, please connect with us in a month.
2). If this guarantee letter has been altered or it has no our stamp, it is useless.
The following conditions need to pay reasonably even in the assurance period:
1). Natural reasons
2). Operating mistakes
3). Voltage is not fit for our operation instruction
4). Repack it without our guides
5). Damaged for borrowing to others
6). Damaged for authorized machine modification
7). Damaged for authorized calibration
8). Authorized transshipment mistake
9). Serve for long distance area
Attentions
1). All customers outside of Guangdong province, whether or not in the warranty period, the
service of transportation and travel expenses paid by the customer.
2).The apparatus try not to be used in the following situations:
A. Vibration, rocking the occasion.
B. Direct sunlight.
C. Hot, dusty, damp places.
D. To ensure safe, AC supply of the machine should be well grounded.
E. Do not use strong solvents (such as: benzene, nitro oil) washing machine.
Page 2 of 17
F. Do not inject water and debris into the machine, prevent damage to electrical components
and electrical shock.
G. Instrument displays the disassemble and debugging can only be measured by the State
Department approved the units and the company, other people not allowed to overhaul.

Notes

Any omissions in this instruction and any add instructions owe to the updated of the
products are written here.

This user is for your operating reference, the notes in it are very useful, please keep it.
Our products are developing, this is user just fit for this kind of tester. Thank you!