PRODUCT BULLETIN: 13001

GE LM6000® GAS TURBINE GENERATOR DRIVE


APPLICATION CONTROL PACKAGE
FEBRUARY 2016

XNSD
XN25
A
A

XN25 XNSD
B B
VSV

VBV

SPRAY INTERCOOLING
DEMINERALIZED VALVE
WATER

WATER PUMP

WT GENERATOR

T2

P0
TBV

VIGV
T48

T25 P48

P25

PS3
LIQUID
FUEL
T3 BLOCK FUEL
VALVE PUMP

DEMINERALIZED
WATER
GAS
FUEL
FUEL BLOCK NOX NOX WATER
CONTROL VALVE VALVE PUMP
FUEL
VALVE

4-20 mA 4-20 mA
FUEL FLOW/PRESSURE INPUT NOX VALVE OUTPUT
4-20 mA 4-20 mA
FCV VALVE OUTPUT LCV OUTPUT
RTD 4-20 mA
T3 (CDT) INPUT (T3 A-B) P48 INPUT
4-20 mA Thermocouple
PS3 (CDP) INPUT (PS3 A-B) T48 INPUT (T48 A-H)
4-20 mA 4-20 mA
P25 INPUT (P25 A-B) TBV OUTPUT
RTD Frequency
T25 INPUT (T25 A-B) XNSD SPEED INPUT 2
4-20 mA Frequency
VIGV OUTPUT (if equipped) XNSD SPEED INPUT 1
4-20 mA
P0 INPUT (P2 A-B)
RTD
T2 INPUT (T2 A-B)
4-20 mA
WATTS INPUT
4-20 mA
SPRAY INTERCOOLING VALVE OUTPUT (SPRINT)
4-20 mA
VBV OUTPUT
4-20 mA
VSV OUTPUT
Frequency
XNSD SPEED INPUT 2
OPTIONAL
Frequency
XNSD SPEED INPUT 1 HMI
PETROTECH APPLICATION CONTROL PACKAGE

COMM PORT

TO PLANT INFORMATION SYSTEM DCS/ SCADA


INTEGRATED CONTROL SYSTEM

Simplified schematic of a Petrotech Application Control Package for a GE LM6000® gas turbine generator drive
integrated into an advanced control system platform
PRODUCT BULLETIN 13001 - GE LM6000® Gas Turbine Generator Drive Application Control Package - Page 2

APPLICATION • Simple installation:


The Petrotech GE LM6000 Application Control Package replaces the
® A dimensionally identical replacement of the control panel or control
OEM obsolete proprietary control packages with a modern, reliable panels subplates is possible, saving substantial architectural and
installation cost. Control panels can be installed one at a time allowing
Petrotech Application Control Package which runs on an advanced
other units to continue operating.
industrial control system. The Application Control Package for the
gas turbine generator set provides all control functions required • Flexibility:
for the reliable and safe operation of the equipment including The Applicatopn Control Package can accommodate many different
fuel control, variable geometry control, sequencing, alarming, etc. control strategies based on the customer’s need and budget.
It also provides spray intercooling water injection (SPRINT) control
for power augmentation or NOx reduction, and dual fuel control for
SCOPE OF SUPPLY
start-up and normal operations as well as for fuel changeover. The Application Control Package for GE LM6000 gas turbine
generator drive system, includes:
ADVANTAGES
Analog inputs, 4-20 mA:
• Integrated control capability:
• P0 Inlet Ambient Air Pressure
Turbine fuel control and sequencing/protection are integrated into a
single platform. This eliminates the need for additional hardware and • P2 LPC Inlet pressure (with VIGVs)
communication links, thereby providing a less complicated, more cost- • P25 HPC Inlet Pressure
effective solution. • PS3 HPC Discharge Pressure (CDP)
• Open architecture system: • P48 Thrust Balance Pressure
Application Control Package’s portability allows customer choice • Gas Fuel Supply Pressure
of platform, reducing need for additional spare parts and training
• Gas Fuel Valve Position Feedback
expenses.
• Generator Megawatts
• Fault tolerant:
• Liquid Fuel Pump Discharge Pressure (if applicable)
Application Control Package is available on fault tolerant controllers
for critical control applications. • Liquid Fuel Valve Position Feedback (if applicable)

• Standard industrial components: • NOx Water Injection Valve Position Feedback


Non-proprietary, commonly available parts are less costly and more • PTB Thrust Balance Pressure
easily serviced by customer’s on-site personnel. Much longer time to • Spray Intercooling Water Pressure (if applicable)
obsolescence than proprietary systems. • Spray Intercooling Water Flow (if applicable)
• Reliability: • Spray Intercooling Air Pressure (if applicable)
ALL control functions are performed by tested and proven industrial • Turbine Flame Detector
control equipment.
• Variable Inlet Guide Vanes (VIGV) Position Feedback (if applicable)
• Simplified interface to DCS or SCADA:
• Variable Bleed Valves (VBV) Position Feedback
Communication tasks are handled with a separate, dedicated module
• Variable Stator Vanes (VSV) Position Feedback
in the PLC, increasing data rate and simplifying network installation.
• Variable Thrust Balance Valve (TBV) Position Feedback
• Non-proprietary interfaces:
Interfaces in the form of 4-20 mA, RTD, frequency, thermo-couple, Analog inputs, frequency:
and dry contact I/O allow simple integration into existing control • Redundant XN25 HPC Speed
equipment, making very low-cost partial control upgrades simple and • Redundant XNSD LPT Drive Shaft Speed
practical.
Analog Thermocouple inputs, mV:
• Improved fuel regulation: • T3 HPC Discharge Temperature
Fast loop sampling rate, combined with modern digital control
• T48 LPT Inlet Temperature
techniques improve steady-state setpoint control, and reduce
overshoot during transients. Analog inputs, RTD:
• Improved start-up reliability: • T2 LPC Inlet Temperature RTD
Special “lean lightoff” procedure ignites all burners with essentially • T25 HPC Inlet Temperature RTD
100% reliability, and with greatly reduced thermal stress. • Gas Fuel Supply RTD
• Improved exhaust temperature monitoring and control: • Liquid Fuel Manifold RTD (if applicable)
Advanced statistical algorithms detect turbine hot/cold spots and • Liquid Fuel Supply RTD (if applicable)
automatically reject failed thermocouples. • Spray Intercooling Water RTD (if applicable)
• Fail-safe features: • Spray Intercooling Air (if applicable)
Redundant overspeeds; open/short monitoring of Analog inputs and
thermocouples; readback monitoring of outputs, and special self-check
features improve safety.
• Improved operator information with optional HMI:
Industrial human-machine interface graphically displays such as start-
up sequencing, speeds, temperatures, operating points, and alarm/
shutdown status. Data logging and trending can be used as part of a
preventative maintenance program. Alternatively, existing HMI can be
reused to reduce initial cost and maintain common operator interface.
PRODUCT BULLETIN 13001 - GE LM6000® Gas Turbine Generator Drive Application Control Package - Page 3

SCOPE OF SUPPLY - Continued Controllers/Special Features


Analog outputs, 4-20 mA: The Petrotech GE LM6000 Gas Turbine Application Control Package
typically includes:
• Gas Fuel Metering Valve Position Setpoint
• Light off
• Liquid Fuel Metering Valve Position Setpoint (if applicable)
• Startup ramp
• NOx Water Injection Metering Valve Position Setpoint
• XNSD control with Droop and Isochronous modes
• Spray Intercooling Water Flow Control Valve Setpoint (if applicable)
• XNSD acceleration control
• Variable Inlet Guide Vanes (VIGV) Position Setpoint (if applicable)
• XN25 control
• Variable Bleed Valves (VBV) Position Setpoint
• XN25 acceleration control
• Variable Stator Vanes (VSV) Position Setpoint
• Pressure Compressor Discharge Pressure (PS3) Control
• Variable Thrust Balance Valve (TBV) Position Setpoint
• Pressure Compressor Discharge Temperature (T3)Control
Operating states:
• Fuel Flow Limit Scheduling
• Firing
• Base, Peak, and Peak Reserve capability
• Warm-up
• Fast Start and Fast Load capability
• Accelerate
• Combustion monitoring with:
• Synchronize
- rT and thermocouple spread alarm and shutdown
• Load (hot and cold sides)
Status, alarms, and shutdowns: - Failed thermocouple detection and automatic rejection
• Fault - Combustion monitoring graphics integrated into the
• XN25 overspeed alarm HMI package
• XN25 underspeed alarm • Variable Inlet Guide Vane (VIGV) Control (if equipped)
• XN25 overspeed shutdown • Variable Bypass Flow (VBV) Control
• XNSD overspeed alarm • Variable Stator Vanes Position (VSV) Control
• XNSD underspeed alarm • Thrust Balance Valve (TBV) Control
• XNSD overspeed shutdown • NOx Water Injection Control
• High T48 alarm • Spray Intercooling Water Injection (SPRINT) Control
• High T48 shutdown • Load control
• Low T48 shutdown • Stopping Modes:
• Rejected thermocouple - Fast-Stop Lockout without monitoring (FSLO)
• Too few thermocouples shutdown - Fast-Stop with Monitoring (FSWM)
• Thermocouple spread alarm - Cooldown Lockout (CDLO/NORMAL)
• Thermocouple spread shutdown - Slow Decel to Minimum Load (SML)
• High Fuel Gas Pressure - Step Decel to Idle (SDTI)
• Gas Fuel Valve Position Error • Dual fuel capability with bumpless on-line transfer
• Liquid Fuel Valve Position Error
OPTIONS FOR COMPLETE
• NOx Water InjectionValve Position Error
CONTROL SYSTEM UPGRADE
• VBV Position Error
• Gas turbine sequencing and protection discrete logic
• VSV Position Error
• Generator sequencing and protection discrete logic
• VIGV Position Error (if applicable)
• Communication interface to DCS or SCADA
• TBV Position Error
• Controller hardware
• Low Spray Intercooling Air Pressure (if applicable)
• Human machine interface unit with licensed software package
• Spray Intercooling Water Pressure (if applicable)
• Complete custom engineered control panel, factory tested and ready
• Transmitter failure alarms
to install
• Transmitter failure shutdowns
• Fuel valve system upgrade
• Thermocouple upgrade
• Flame sensor upgrade
• Vibration system upgrade
• Installation and commissioning
• Training

Petrotech, Inc. Phone: +1 (504) 620-6600


151 Brookhollow Esplanade Fax: +1 (504) 620-6601
New Orleans, Louisiana 70123 Email: info@petrotechinc.com
USA Website: www.petrotechinc.com

This document is a Petrotech, Inc. copyrighted intellectual property and may be changed at any time without notice.

You might also like