Download as pdf
Download as pdf
You are on page 1of 7
300 x 300 x 250 OEEP SUMP 150 { | DUCT ENTRANCE —f--}e--4 aly | A LI} fe © Ww 4 > iso, | ¥ ! | 50 #25 PULLING-IN IRON 150 PLAN FOR MANHOLE FRAME & COVER, SEE FED. SPEC. A-A~60005 FIG. 4, SIZE 28 AND FIG. 12, SIZE 28 RESPECTIVELY 150 300 BRICK COLLAR LINED UP y WITH CEMENT MORTAR rE 0 i DUCT ENTRANCE Ss ["— Ue REINF. 600 mm (TYP.) 925 PULLING-IN IRON 150 2 8 150 5 REINF. AT 150 EW WATERSTOP AT ALL op, sioes & BoraM ———_-H 7 CONSTR. JTS. (TYP.) SLOPE. 1:40 Meese Te = TO SUMP Ny 7 250 fe GROUND ROD &e CLAMP —SECTION AWA NOTE: FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE AND PULLING-IN MANHOLE OHENSONS ; IRONS, SEE PLATE UG-7. TYPE A B (AT _HIGH PT. T MINIMUM CONCRETE COMPRESSIVE Do Fat STRENGTH SHALL BE 21 MPa. STANDARD ELECTRICAL MANHOLE (NONTRAFFIC) TYPES 1 & 2 SKETCH DATE FEBRUARY 2000 | STYLE UG-1 12" x 12" x 10" DEEP ‘SUMP , ote 7/8" PULLING-IN IRON + CONCRETE OR TOP ROADWAY #5 @ 6" EW, TR. ~ ——~ A _ ee A _! DUCT ENTRANCE. LOCATION TO BE AS INDICATED j= 8" BLACK =r FOR MANHOLE FRAME & COVER, SEE FED. SPEC. A~A~60005, FIG. 1, SIZE 30A AND FIG. 8, SIZE 30A, RESPECTIVELY BRICK COLLAR LINED UP WITH + = CEMENT MORTAR i 6" MIN. #4 @ 6” EW EF. aT bb a: 7/8" PULLING-IN IRON —| H 8° — DUCT ENTRANCE SLOPE 1:40 TO SUMP” WATERSTOP AT ALL CONSTR. JTS. (TYP.) #4 © 6” TaB 10" 8 2k NM LAP REINF. 24” (TYP.) SECTION AWA [GROUND ROD & CLAMP t NOTES: 1, MANHOLE AND COVERS ARE DESIGNED FOR MAXIMUM WHEEL LOAD IN ACCORDANCE WITH AASHTO HS20-44. 2. FOR DETAILS OF CABLE RACKS, DUCT ENTRANCE AND PULLING-IN IRONS, SEE PLATE UG-7. MANHOLE DIMENSIONS 3. MINIMUM CONCRETE COMPRESSIVE TPE B__|C (AT HIGH PT, S a ee ) STRENGTH SHALL BE 3000 psi 3 feof 6-0 oe STANDARD ELECTRICAL MANHOLE (TRAFFIC) TYPES 3 & 4 SKETCH DATE FEBRUARY 2000 | STYLE UG-2 7/8"6 PULLING-IN IRON 8 at 12" X 12" X 10" DEEP SUMP . A) K {* DUCT ENTRANCE. LOCATION TO BE AS INDICATED. ¥ 0” OPENING PLAN ee VAT Loe TK PL-PROVIDE UFTING HOLES F495 Nive 1 145 N17: ares? 5/8" X 5/8" BAR bet a 4" X 3/4" (SEE NOTE 3) BARS COVER DETAIL. 5 FOR MANHOLE FRAME, SEE FED SPEC, A-A-60005, FIG 3, SIZE 244, STYLE B, 4” FLANGE. BRICK COLLAR LINED UP WITH CEMENT MORTAR. #5 @ 6" EW. EF. TOP, BOTTOM & SIDES 7/8"® PULLING-IN IRON e LAP REINF, 24” (TYP.) NOTES: MANHOLE AND COVERS ARE SLOPE 1:40 TO SUMP DESIGNED FOR MAXIMUM WHEEL LOAD OF 50,000 LB OR DUAL WHEEL LOAD OF 90,000 LB. WATERSTOP AT ALL 2. FOR DETAILS OF CABLE RACKS, CONSTR. JTS. (TYP.) GROUND ROD & cue 7 SECTION A-A MANHOLE” DIMENSIONS) TYPE C_(AT HIGH PT.) 5 o-6" 6 "ft DUCT ENTRANCE AND PULLING-IN IRONS, SEE PLATE UG-7. 3. COVER SHALL BE MADE OF STRUCTURAL STEEL CONFORMING TO ASTM A 36/A 36M. 4, MINIMUM CONCRETE COMPRESSIVE STRENGTH SHALL BE 3000 psi. 6 STANDARD ELECTRICAL MANHOLE (AIRFIELD) TYPES 5 & 6 SKETCH DATE FEBRUARY 2000 | STYLE UG=3 1/2" FLOOR PLATE. RAISED 1/2" PLUG WELD ATTEN 3 i 8 24/2" X 3/8" SEAL. 1 E aE y felbeo Fo Ohe LL : SIDE OF THE DG0R ZN : Ue SEAL DETAL & COVER PLAN OF COVER ‘| 3/4" 78. CUT HINGE PLATE 31 AS SHOWN Te 5rX 5" HINGE tt Z SEAL, SEE ANCHOR 1/2" FLOOR PL. OAT ABOVE 15/12 na pune FasSeD PATTERN SECTION B=8_ 1/2'® PLUG WELD 5/8" @ ANCHOR ROD é ii We ¢ 6th 2 1/2%21/2 x 3/8 (PER Sos) DUCT ENTRANCE Wt x a2" x 12" SECTION OF FRAME 8 DEEP SUMP 1/2", PLUG WELDS @ 8" OC. MAX. —— A f 7 Ft\— DUCT ENTRANCE s fo S x . a. <|7/816 Lt oe atl 6 LI) s}ebtune— SHI] Li) AAP eaintn ou He SLOPE 1:40 oY NT TSE SS jo sume 1 Ebe f4 ©. 12 ANCHORS i SIDES 6 (COVER NOT SHOWN) EES AND BOTTOM PLAN WATERSTOP_AT ALL grag, s00 WER) os 1. FOR DETALS OF CABLE RACKS, DUCT. ENTRANCE AND PULLING=IN SECTION IRONS, SEE PLATE UG-7. HANDHOLE [DIMENSIONS 2. MINMUM. CONCRETE COMPRESSIVE TYPE ry STRENGTH ‘SHALL BE 3000 psi. i so" 2 +0" STANDARD ELECTRICAL_ HANDHOLE (NONTRAFFIC) TYPES 1 & 2 SKETCH DATE FEBRUARY 1996 | STYLE UG-—4 1/2" 6 PLUG WELD B -| 4/2", PLUG WELD AT 6" OC. HINGE—-WELDED TO. FRAME & COVER A 1/2", PLUG WELD AT 6" 0, C1 ‘SUMP. REMOVABLE W 8 X 40 3X 3/8" X 4-6" PL NOTE: _STIFFENERS SHOWN TYP. BOTH SIDES DUCT ENTRANCE. LOCATION TO BE AS INDICATED “ON THE PROJECT DRAWING 7 apt y ae L6X 3 1/2 x 5/16 3—! Sx 8/8 x PL . my age 1/2°6 STEEL ROD wines hey XE AL PN yg 2 “ee _ finn ee c a prerveaeiaey. | [ee AT ALL tt @ 12" EW. & CONSTR. JTS. (TYP.) =F. SIDES & BOTTOM SECTION A NOTES 1. ENTRANCE OF DUCTS INTO HANDHOLE MAY 3 1/2x3 1/2x1/4 ~ pveligr 'e (SEE NOTE 4) oc. SECTION C-C 1/27 P.E.d. ALL AROUND PAVING OR GRADE 11/4 x 1/8" BE MADE ON SIDE FACES O8 CORNERS Acton’ (Ese 2. FOR DETAILS OF CABLE RACKS, DUCT Co ENTRANCE AND PULLING-IN IRONS, FAL AZ EW. SEE PLATE UG-7. Er. SES & 3. HANDHOLE AND COVER IS DESIGNED FOR WAXIMUM SINGLE WHEEL LOAD OF . 50,000 LB. OR DUAL WHEEL LOAD OF 10" coun ROD 90,000 LB. A. COVER SHALL BE MADE OF STRUCTURAL etal (ramorone [omens “STEEL CONFORMING TO ASTM A 36/A 36M. SECTION B—B_ |_TFE 5. MINIMUM COMPRESSIVE STRENGTH OF + CONCRETE SHALL BE 3000 psi. STANDARD ELECTRICAL_HANDHOLE (TRAFFIC/AIRFIELD) TYPES 3 & 4 SKETCH DATE FEBRUARY 1996 | STYLE UG—-5 CONCRETE. RING STANLESS STEEL HEX BOLT AND ‘AROUND BOX WASHER ” PULL SLOT: aS BOX AND SE ¢ ~S si RESISTANT SURFACE coupacten EARTH s | aE, fats |. NO ‘SECTIONAL CRUSHED ROCK: BOX WHEN REQUIRED TYPE HANDHOLE SIZING 5 | 12" xX 12" X 24” DEEP 6 | 12" x 18" x 24" DEEP 712" x 24" x 24" DEEP 8 9 24" X 36" X 24” DEEP 30" X_48” X 24" DEEP HANDHOLE REQUIREMENTS 1. HOUSING SHALL BE A POLYMER CONCRETE REINFORCED WITH A HEAVY WEAVE FIBERGLASS REINFORCING WITH COMPRESSIVE STRENGTH OF NO LESS THAN 10,000 psi, 2. COVER AND BOX SHALL WITHSTAND A SERVICE LOAD OF NO LESS THAN 15,000 LBS OVER A 10" x 10" AREA, 3. PROVIDE STAINLESS STEEL BOLTS AND INSERTS. 4. PROVIDE WITH (2) 2 1/2" MOUSEHOLES. 5. PROVIDE LABEL "ELECTRICAL" FOR POWER HANDHOLES OR “TELEPHONE” FOR TELEPHONE HANDHOLES, OR AS INDICATED. STANDARD ELECTRICAL HANDHOLE (NONTRAFFIC) (COMPOSITE/FIBERGLASS) TYPES 5, 6, 7, 8 & 9 SKETCH DATE OCTOBER 1997] STYLE UG-6 1"6 NUT . x CONCRETE WALL: 13/16 11/2"(MIN) 2 8 3/8" FISD RSS 1727 2172" 3/16" PLE 11/4" SLEEVE =] F *LOCKWASHER 7“. 1. 2" [Pet dla 1/2°6 Dia WASHER ele /2°9, a Wa Za /9% spot , FILLET WELD: \4 3” 2.1/2" RAD ve u-par—~” & CAST IN PLACE ALTERNATE METHOD NOTE ‘ALL METAL PARTS SHALL BE HOT DIP GALVANIZED DETAIL OF PULLING—IN IRON WALL OF MANHOLE a 17” MIN. TYPICA| RACK INSIDE FACE 7] OF MANHOLE —| 4s TYPICAL DUCT ENTRANCE DETAILS (PULLING-IN IRONS, CABLE RACK AND DUCT ENTRANCE) SKETCH DATE FEBRUARY 1996 | STYLE UG-—7

You might also like