q 3 pressure stages
Functional Description
The pilot operated pressure relief valve is used for a as proportional pressure relief valve for very small flow
3 -1
pressure control in hydraulics circuits. It consists of a rates to 2dm .min .
main and a pilot stage. The main stage consists of valve With respect of the design and desired performance it is
body (1), spool (2), springs (3) and nozzles (4). The main very important before to unvented the air from actuation
stage is controlled by pilot flow rate, which flows through system on the pilot valve. For this is on the actuation
the spool and the nozzle. The pilot stage, due to the force system installed the air bleeding screw (7).
of the proportional solenoid (6) to the popped (5),
produces desired pressure drop in the pilot seat. This The basic surface coating of the valve is zinc.
pressure drop, which acts at the spool of the main stage,
controls the pressure at the valve inlet P. On the pilot side Attention: The proportional pressure relief valve is not
the main stage is equipped with the 3/4-16 UNF cavity mechanically protected and it does not perform the relief
and it can be used it withexcessive current applied could valve function. By the coil overexciting the pressure
cause the valve to function beyond stated pressure grows above the mentioned pressure ranges.
limits. The pilot stage can be also used separately, such
2 3 4 1 5 6 7
P P
T T
1
HA 5117
Ordering Code
SR4P-B2 / -
Seals
without designation NBR
Proportional Pilot Operated
V FPM (Viton)
Pressure Relief Valve Type of solenoid coil
E1 with terminal for the connector*
E2 with terminal for the connector*, and
quenching diode**
E3 with AMP-Junior-Timer-connectorr
High performance H E4 with AMP-Junior-Timer-connectorr and
quenching diode**
* from EN 1745301-803-A
** Preferred exciting coils of the solenoid
Other coils on demand see catalog HA8007
Pressure range
Nominal solenoid supply voltage
up to 120 bar (1740 PSI) 12
up to 210 bar (3046 PSI) 21 12 supply voltage 12V DC
up to 350 bar (5076 PSI) 35 24 supply voltage 24 V DC
SR1P-A2 / -
Seals
without designation NBR
Proportional Direct Operated V FPM (Viton)
Pressure Relief Valve
Type of solenoid coil
E1 with terminal for the connector*
E2 with terminal for the connector*, and
quenching diode**
High performance H E3 with AMP-Junior-Timer-connectorr
E4 with AMP-Junior-Timer-connectorr and
quenching diode**
* from EN 1745301-803-A
** Preferred exciting coils of the solenoid
Other coils on demand see catalog HA8007
Pressure range
Nominal solenoid supply voltage
up to 120 bar (1740 PSI) 12
up to 210 bar (3046 PSI) 21 12 supply voltage 12V DC
up to 350 bar (5076 PSI) 35 24 supply voltage 24 V DC
SR6H-B2 / -
Main Stage is Externally Controlled
Spool Design Relief Valve
Seals
without designation NBR
High performance H V FPM (Viton)
2
HA 5117
Technical Data
Cartridge thread 7/8-14 UNF-2B
Maximum operating pressure at ports P bar (PSI) 350 (5076)
Maximum operating pressure at port T* bar (PSI) 100 (1450)
Flow rate range L/min (GPM) 5 ¸ 60 (1.32 ¸ 15.85)
Hydraulic fluid Hydraulic oils of power classes (HL, HLP) to DIN 51524
Fluid temperature range ( NBR / FPM) °C (°F) -30 ...90 (-22 ...194)
Ambient temperature, max. °C (°F) +50 (122)
2
Viscosity range mm /s (SUS) 10 ... 500 (49 ... 2450)
Duty cycle % 100
Enclosure type to EN 60 529 IP67 (IP 65)
Maximum valve tightening torque Nm ( lbf.ft) 35+5 (25.81+3.68)
Control Hz PWM-signal 160
Maximum degree of fluid contamination Class 21/18/15 according to ISO 4406 (1999).
Minimum prssure on Q = 10 L/min ( 2.64GPM) bar (PSI) 3 (43.51)
Hysteresis % <6
Weight of the whole valve 0,53 (1.168)
Main stage kg (Ib) 0,13 (0.287)
Pilot stage with exciting coil 0,40 (0.882)
Mounting position any, preferably horizontal
*Pressure in T influences p=f(I) characteristics
p-I Characteristics 2
Measured at n = 32 mm /s (156 SUS)
(5076) 350 3
(4351) 300
Pressure p [bar (PSI)]
ATTENTION:
(3626) 250
The proportional pressure relief valve is
2 not mechanically protected and it does
(2901) 200 not perform the relief valve function. By
the coil overexciting the pressure grows
(2176) 150 above the mentioned ranges.
1
(1450) 100
3 Pressure range 35
(725) 50 2 Pressure range 21
1 Pressure range 12
0 200 400 600 800 1000
Current I [mA]
3
HA 5117
p-Q Characteristics Measured at n = 32 mm /s (156 SUS)
2
4
(5801.5) 400
Pressure range p [bar (PSI)]
(5076.3) 350
(4351.1) 300
3
(3625.9) 250
(2900.7) 200
2
(2175.5) 150
4 Pressure range 35
(1450.4) 100 3 Pressure range 21
(725.2) 50 1 2 Pressure range 12
1 Min. pressure setting
0 10 20 30 40 50 60
41(1.614)
7/8-14UNF-2A
Æ37(1.457)
P
Æ15,82
(0.623)
HEX 27
HEX 24
3/4-16UNF-2A
7/8-14UNF-2A
P
(0.623)
P
Æ15,82
(0.498)
Æ12,65
T T
4
HA 5117
Cavity 7/8-14 UNF Dimensions in millimeters and (inches))
1,6
0,05(0.002) A
min 16(0.63)
0,05(0.0002) A
2,5+0,4(0.1/0.11)
max 1(0.04)
0,05(0.0002) A
A
45°
Æ24±0,05(0.94/0.95)
min Æ34(1.34)
30°
(0.624/0.627)
7/8-14 UNF-2B
Æ15,87+0,05
3,2
30°
1,6
1,6
min14(0.55) R 0,2(0.01)
,
0.04(0.001) A ( (
A
A
3,2
0.05(0.002)
)
0.002
20.63+0.4 (0.812+0.016)
0.05(
min 14.3(0.563)
2.5+0.4(0.0984+0.016)
max. 1(0.039)
A
min. Æ 25 (0.984)
30°
3/4-16 UNF-2B
30° ±2°
90° ±10°
3,2
1,6
Æ12.7 +0.05 (0.499+0.002)
1,6
+0.1 (0.811+0.004)
5
HA 5117
Type of the Solenoid Coil
Designation Dimensional sketch Description
41(1.614)
connector, EN 175301-803-A
29(1.142)
Solenoid coil with integrated quenching diode
(bipolar transil diode) and terminal for
E2 the electrical connector, EN 175301-803-A
42(1.654)
Solenoid coil with integrated quenching diode
E4 (bipolar transil diode) and terminal for
AMP-Junior-Timer electrical connector.
Valve Body
- detailed valve body ordering code refer to data sheet HA 0018
Spare Parts
1. Solenoid coil
Type of the coil
Type designation of
E2 E4
the coil voltage
Ordering number
01200 28145600 28145800
02400 28145100 28145300
Caution!
The packing foil is recyclable.
The protective plate can be returned to manufacturer.
The technical information regarding the product presented in this catalogue is for descriptive purposes only. It should
not be construed in any case as a guaranteed representation of the product properties in the sense of law.