Download as pdf or txt
Download as pdf or txt
You are on page 1of 13

RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA

Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 1 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Permanent Calibration
MECHANICAL-
DIMENSION Using Sine Bar And
(BASIC Angle- Bevel Slip Gauges Blocks
1 0 ° to 180 ° 3.78 '
MEASURING Protractor L.C.: 5' By Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Bore Dial Gauge Using dial calibration
(BASIC
2 (Transmission) L.C.: tester by upto to 1 mm 3.0 µm
MEASURING
0.001 mm comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Sine Bar And
(BASIC Combination Set Slip Gauges Blocks
3 0 ° to 180 ° 3.78 '
MEASURING (Angle) L.C.: 5' By Comparison
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Depth Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.01 mm
4 and Surface Plate By 0 to 150 mm 5.2 µm
MEASURING (Micrometer screw
Comparison Method
INSTRUMENT, error)
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 2 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Depth Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.01 mm
5 and Surface Plate By 0 to 300 mm 7.5 µm
MEASURING (Micrometer screw
Comparison Method
INSTRUMENT, error)
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
(BASIC And Electronic Probe
6 Dial Snap Gauge 0 to 300 mm 2.0 µm
MEASURING By Comparision
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Dial Thickness Using Slip Gauges
(BASIC
7 Gauge L.C.: 0.001 Blocks By 0 to 25 mm 3.3 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.001 mm
8 By Comparison 0 to 150 mm 3.6 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)
MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.001 mm
9 By Comparison 150 mm to 300 mm 8.4 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 3 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.001 mm
10 By Comparison 300 mm to 600 mm 13.23 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)
MECHANICAL-
Using Slip Gauge Set
DIMENSION
and Electronic Probe
(BASIC Feeler Gauge
11 with comparator 0.10 mm to 2 mm 2.5 µm
MEASURING (Thickness)
stand By
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Slip Gauge Set
DIMENSION
and Electronic Probe
(BASIC
12 Foil (Thickness) with comparator 0.10 mm to 1 mm 2.5 µm
MEASURING
stand By
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
Using Slip Gauge Set
DIMENSION Height Setting
and Electronic Probe
(BASIC Master / Flush Pin
13 with comparator 2 mm to 275 mm 3.64 µm
MEASURING Gauge / Width
stand by
INSTRUMENT, Gauge (Diameter)
Comparision Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Internal Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.01 mm
14 By Comparison 5 mm to 300 mm 6.8 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 4 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
15 tester by 0 to 0.2 mm 3.44 µm
MEASURING 0.002 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
16 tester by 0 to 1 mm 4.0 µm
MEASURING 0.01 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
17 tester by 0 to 0.14 mm 3.41 µm
MEASURING 0.001 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
(BASIC Micrometer And Electronic Probe
18 200 mm to 300 mm 6.56 µm
MEASURING Standard (Length) By Comparision
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
(BASIC Micrometer And Electronic Probe
19 25 mm to 200 mm 3.52 µm
MEASURING Standard (Length) By Comparision
INSTRUMENT, Method
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 5 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Using Slip Gauge Set
(BASIC And Electronic Probe
20 Pin Set (Diameter) 1 mm to 20 mm 1.88 µm
MEASURING By Comparision
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Pistol Caliper
21 By Comparison 0 to 100 mm 32.8 µm
MEASURING (Thickness)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
Using Slip Gauge Set
DIMENSION
Plain Plug Gauge / and Electronic Probe
(BASIC
22 OD Master with comparator 2 mm to 275 mm 3.64 µm
MEASURING
(Diameter) stand By
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Dial
(BASIC Plunger Type Dial
23 calibration tester by 0 to 1 mm 2.9 µm
MEASURING L.C.: 0.001mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Plunger Type Dial
24 tester by 0 to 5 mm 1.5 µm
MEASURING L.C.: 0.002 mm
comparison method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 6 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Plunger Type Dial
25 tester by 0 to 25 mm 4.43 µm
MEASURING L.C.: 0.01 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Snap Gauge (Gap
26 By Comparison 101 mm to 300 mm 5.5 µm
MEASURING size)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Snap Gauge (Gap
27 By Comparison 3.5 mm to 100 mm 1.81 µm
MEASURING size)
Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL- Thread Plug Gauge/ Using Thread
DIMENSION Spline Plug Gauge/ Measuring Wires,
(BASIC Taper Thread Plug Floating Carriage
28 2 mm to 100 mm 6.6 µm
MEASURING Gauges (Major Micrometer and
INSTRUMENT, diameter, Simple measuring pin by
GAUGE ETC.) effective diameter) comparison method
MECHANICAL-
DIMENSION V Block (Parallelism Using Surface Plate,
(BASIC of axis of base Test Mandrels & Dial
29 Up to 100 mm 8.6 µm
MEASURING surfaces and side Indicator by
INSTRUMENT, surfaces) comparison method
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 7 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION Using surface plate,
(BASIC V Block test mandrels & dial
30 10 mm to 100 mm 8.6 µm
MEASURING (Symmetricity) indicator by
INSTRUMENT, comparison method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Vernier Caliper L.C.:
31 and Surface Plate By 0 to 300 mm 7.27 µm
MEASURING 0.010 mm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Vernier Caliper L.C.:
32 and Surface Plate By 0 to 600 mm 14.9 µm
MEASURING 0.010 mm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Depth Using Slip Gauge Set
(BASIC
33 Gauge L.C.: 0.01 and Surface Plate By 0 to 300 mm 20.89 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Height Using Slip Gauge Set
(BASIC
34 Gauge L.C.: 0.01 and Surface Plate By 0 to 300 mm 8.11 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 8 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Vernier Height Using Slip Gauge Set
(BASIC
35 Gauge L.C.: 0.01 and Surface Plate By 0 to 600 mm 20.4 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 9 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Mobile Facility
MECHANICAL-
DIMENSION
Bore Dial Gauge Using dial calibration
(BASIC
1 (Transmission) L.C.: tester by upto to 1 mm 3.0 µm
MEASURING
0.001 mm comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION Using Slip Gauge Set
(BASIC And Electronic Probe
2 Dial Snap Gauge 0 to 300 mm 2.0 µm
MEASURING By Comparision
INSTRUMENT, Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Dial Thickness Using Slip Gauges
(BASIC
3 Gauge L.C.: 0.001 Blocks By 0 to 25 mm 3.3 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION External Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.001 mm
4 By Comparison 0 to 150 mm 3.6 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 10 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
Using Slip Gauge Set
DIMENSION Height Setting
and Electronic Probe
(BASIC Master / Flush Pin
5 with comparator 2 mm to 275 mm 3.64 µm
MEASURING Gauge / Width
stand by
INSTRUMENT, Gauge (Diameter)
Comparision Method
GAUGE ETC.)
MECHANICAL-
DIMENSION Internal Micrometer
Using Slip Gauge Set
(BASIC L.C.: 0.01 mm
6 By Comparison 5 mm to 300 mm 6.8 µm
MEASURING (Micrometer screw
Method
INSTRUMENT, error)
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
7 tester by 0 to 0.2 mm 3.44 µm
MEASURING 0.002 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
8 tester by 0 to 1 mm 4.0 µm
MEASURING 0.01 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Lever Type Dial L.C.:
9 tester by 0 to 0.14 mm 3.41 µm
MEASURING 0.001 mm
comparison method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 11 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
Using Slip Gauge Set
DIMENSION
Plain Plug Gauge / and Electronic Probe
(BASIC
10 OD Master with comparator 2 mm to 275 mm 3.64 µm
MEASURING
(Diameter) stand By
INSTRUMENT,
Comparison Method
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Dial
(BASIC Plunger Type Dial
11 calibration tester by 0 to 1 mm 2.9 µm
MEASURING L.C.: 0.001mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Plunger Type Dial
12 tester by 0 to 5 mm 1.5 µm
MEASURING L.C.: 0.002 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using dial calibration
(BASIC Plunger Type Dial
13 tester by 0 to 25 mm 4.43 µm
MEASURING L.C.: 0.01 mm
comparison method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Snap Gauge (Gap
14 By Comparison 3.5 mm to 100 mm 1.81 µm
MEASURING size)
Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 12 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

MECHANICAL-
DIMENSION
Using Slip Gauge Set
(BASIC Vernier Caliper L.C.:
15 and Surface Plate By 0 to 300 mm 7.27 µm
MEASURING 0.010 mm
Comparison Method
INSTRUMENT,
GAUGE ETC.)
MECHANICAL-
DIMENSION
Vernier Height Using Slip Gauge Set
(BASIC
16 Gauge L.C.: 0.01 and Surface Plate By 0 to 300 mm 8.11 µm
MEASURING
mm Comparison Method
INSTRUMENT,
GAUGE ETC.)

This is annexure to 'Certificate of Accreditation' and does not require any signature.
RELIABLE METROLOGICAL LABORATORY LLP, FLAT NO 302 B, WING CHANAKYA
Laboratory Name : NAGARI, KANDGE PARK, HINGANE KHURD SINHGAD ROAD, PUNE, MAHARASHTRA,
INDIA

Certificate Number CC-3897 Page No 13 of 13


Validity 17/04/2024 to 16/04/2026 Last Amended on 06/05/2024

Measurand or Reference
Measurement range and
Material/Type of instrument * Calibration and
Calibration or Measurement additional parameters
S.No Discipline / Group or material to be calibrated Measurement
Method or procedure where applicable(Range
or measured / Quantity Capability(CMC)(±)
and Frequency)
Measured /Instrument

Site Facility
MECHANICAL-
DIMENSION
300 mm x 300 mm 2.34 x sqrt ( L+W
(BASIC Using Sprit Level by
1 Surface Plate to 2000 mm x 2000 )/125 µm, where L&
MEASURING comparison method
mm W in mm
INSTRUMENT,
GAUGE ETC.)
* CMCs represent expanded uncertainties expressed at approximately the 95% level of confidence, using a coverage factor of k = 2.

This is annexure to 'Certificate of Accreditation' and does not require any signature.

You might also like