ULTRAFILTRATION SYSTEM DESIGN

NORIT MEMBRANES

Input Parameters Output Parameters

Select source of water Wastewater 2 Gross Flux, gfd

Select inlet turbidity, NTU <5 2 Total No. of membranes


35 No. of PT for XIGA system
Select inlet O&G, mg/l <5 3 UF recovery, %

Enter permeate flow, m3/h 375 Backflush flow, m3/h

Select system Xiga 2 CEB flow, m3/h

Select Membrane Area, sq.ft 430 1 Pretreatment flow, m3/h

Valve changeover time, sec HCl CEB Pump (30%), lph


For one backflush 10 1
For one CEB 15 1 NaOCl CEB Pump (5%) lph

Total BF volume, m3/d

Total CEB volume, m3/d

No. of BF per hour

BF duration, sec

No. of CEB per day


35

232
58
74.6

2361.7

1180.9

551.1

2053.7

4723.5

2834.1

236.2

60