HLC - TLC - RP - 12 - G012 - STR Connection Typ 3

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 3

Project code: HLC-N17

MAIN ROOF CONNECTIONS CALCULATION


Number: HLC_TLC_RP_12_G012
N17 NORTHCOTE DEVELOPMENT Calc. by Date Rev
Project
4 FRASER AVENUE, NORTHCOTE, AUCKLAND, NZ PhuocDao 7/11/2023
Checked by Date A
Item STR CONNECTION TYP 3
VuHuynh 7/11/2023

Design code
NZS 3404-1997: Steel structures Standard (I)

Overview

SHS 100 x 3
Load applies to support is taken from etabs result
Fz = 25 kN
Fx = 3 kN
Fy = 15 kN

II. Weld group 1 check


Load Compositions

MAIN ROOF CONNECTIONS CALCULATION Number: HLC_TLC_RP_12_G012


Jun 2023 1/3 Project Code: HLC
Total force applies to weld conection
Vx* Vy* Fz * M x* My* M z* Level arm z direction z= 85 mm
kN kN kN kNm kNm kNm Level arm x direction x = 160.33 mm
3.0 15.0 25.0 0.0 4.3 0.0
Nominal tensile strength of weld metal fuw = 480 MPa
Sizes of fillet weld (equal leg fillet weld) tw = 6 mm
Design throat thickness tt = 4.2 mm
Reduction factor kr = 1 -
Φ= 0.80
Weld section area Aw = 12.9 cm2
Polar moment of inertia direction X Ix = 190.4 cm4
Polar moment of inertia direction Y Iy = 172.9 cm4
Polar moment of inertia direction Z Iz = 363.3 cm4
Tensile stress caused by Fz* σs,z1* = Fz* / Aw = 1.9 kN/cm2
Tensile stress caused by My* σs,z2* = My* x / Iy = 27.2 kN/cm2
Total tensile stress σs,z* = 29.1 kN/cm2
Shear stress caused by Vx* τx* = Vx* / Aw = 0.23 kN/cm2
Shear stress caused by Vy* τy* = Vy / Aw = 1.16 kN/cm2
Total shear force τxy* = 1.18 kN/cm2
(σs,z*2+/ 3τxy*2)0.5 / (Φfuw) = 0.76 -

II. Weld group 2 check


Load Compositions
Total force applies to weld conection
Vx* Vy* Fz * M x* My* M z* Level arm z direction z= 0 mm
kN kN kN kNm kNm kNm Level arm x direction x= 50 mm
25.0 15.0 3.0 0.0 0.2 0.0
Nominal tensile strength of weld metal fuw = 480 MPa
Sizes of fillet weld (equal leg fillet weld) tw = 3 mm
Design throat thickness tt = 2.1 mm
Reduction factor kr = 1 -
Φ= 0.80
Weld section area Aw = 5.7 cm2
Polar moment of inertia direction X Ix = 126.2 cm4
4
Polar moment of inertia direction Y Iy = 40.2 cm
Polar moment of inertia direction Z Iz = 166.4 cm4
Tensile stress caused by Fz* σs,z1* = Fz* / Aw = 0.5 kN/cm2
Tensile stress caused by My* σs,z2* = My* x / Iy = 3.2 kN/cm2
Total tensile stress σs,z* = 3.7 kN/cm2
Shear stress caused by Vx* τx* = Vx* / Aw = 4.36 kN/cm2
Shear stress caused by Vy* τy* = Vy / Aw = 2.62 kN/cm2
Total shear force τxy* = 5.09 kN/cm2
(σs,z*2+/ 3τxy*2)0.5 / (Φfuw) = 0.25 -

III. Connected plate check


MAIN ROOF CONNECTIONS CALCULATION Number: HLC_TLC_RP_12_G012
Jun 2023 2/3 Project Code: HLC
Cross-section Width b= 85 mm
Thickness t= 10 mm
Steel plate grade SS400 fy = 23.5 kN/cm2
Cross-section area A= 8.5 cm2
Moment of inertia of cross-section Wy = 1.42 cm3
Applied tensile force Fz* = 25.0 kN
Tensile stress σ1 = Fz* / A = 0.3 kN/cm2
Bending moment My = 10 kNcm
Bending stress σ2 = My* / W y = 7.1 kN/cm2

MAIN ROOF CONNECTIONS CALCULATION Number: HLC_TLC_RP_12_G012


Jun 2023 3/3 Project Code: HLC