FUJIFILM FCR XG5000 Specifications

Standard Components: Number of Stackers: 4


• FCR XG5000 Image Reader (Model: CR-IR 362)
Reading Gray Scale: 12 bits
• AC power cord
Network: 10 Base T/100 Base TX
Other System Components (sold separately):
• CR Console Plus (sold separately) Dimensions (W ✕ D ✕ H): 655 ✕ 740 ✕ 1480 mm (26” ✕ 29” ✕ 58”)
• Image Recorder : DRYPIX 4000 / 7000
Weight: 270 kg (595 lbs.)
• ID Card Writer
• FCR Data Management System Power Supply Conditions:
Single phase 50-60Hz
Supplies:
AC120-240V ±10%
Imaging Plate:
7A (max)
• ST-VI (Standard): 14” ✕ 17”, 14” ✕ 14”, 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm
• HR-V (High Resolution): 24 ✕ 30 cm, 18 ✕ 24 cm Environmental Conditions:
IP Cassette: • Operating Conditions:
• Type CC: 14” ✕ 17”, 14” ✕ 14”, 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm Temperature: 15-30°C
• Type LC: 35.4 ✕ 124.5cm, 35.4 ✕ 101.7cm, 35.4 ✕ 83.0cm, 25.2 ✕ 58.0cm, 24.0 ✕ 57.0cm Humidity: 40-80%RH (No dew condensation)
• Non-operating Conditions:
Time Required for IP Feed/Load: Temperature: 0-45°C
IP Type IP Size Required Time Humidity: 10-90%RH (No dew condensation)
ST-VI 14” ✕ 17” (35 ✕ 43cm) Approx. 60 sec. FUJI COMPUTED RADIOGRAPHY
ST-VI 14” ✕ 14” (35 ✕ 35cm) Approx. 54 sec.
ST-VI 10” ✕ 12” Approx. 50 sec. Dimensions Unit: mm (in.)
ST-VI 8” ✕ 10” Approx. 40 sec.
740 (29) 655 (26)
ST-VI 24 ✕ 30cm Approx. 51 sec. A high-efficiency FCR reader offering quality imaging and
ST-VI 18 ✕ 24cm Approx. 42 sec.
HR-V 24 ✕ 30cm Approx. 65 sec. all-round versatility for superior diagnostic capability.
HR-V 18 ✕ 24cm Approx. 55 sec.

Processing Capacity
(in high-pixel density two-image output format):

1480 (58)
When connected to
IP Type IP Size
DRYPIX 7000/CR Console Plus
ST-VI 14” ✕ 17” (35 ✕ 43cm) Approx. 103 IPs/hr.
ST-VI 14” ✕ 14” (35 ✕ 35cm) Approx. 120 IPs/hr.
ST-VI 10” ✕ 12” Approx. 128 IPs/hr.
ST-VI 8” ✕ 10” Approx. 165 IPs/hr.
ST-VI 24 ✕ 30cm Approx. 128 IPs/hr.
ST-VI 18 ✕ 24cm Approx. 165 IPs/hr.
HR-V 24 ✕ 30cm Approx. 90 IPs/hr.
HR-V 18 ✕ 24cm Approx. 110 IPs/hr.

Time to Print on DRYPIX 7000 through network via CR Console:


Approx. 110 sec.

Image Reading (Image output is via CR Console)


IP Cassette with Imaging Plate
Standard Pixel-density High Pixel-density
Reading Size Type LC Type CC
Pixels/mm Number of Pixels Pixels/mm Number of Pixels

14” ✕ 17” (35 ✕ 43 cm) 5 1760 ✕ 2140 10 3520 ✕ 4280


14” ✕ 14” (35 ✕ 35 cm) 5 1760 ✕ 1760 10 3520 ✕ 3520
10” ✕ 12” 6.7 1670 ✕ 2010 10 2505 ✕ 3015
8” ✕ 10” 10 2000 ✕ 2510 10 2000 ✕ 2510
24 ✕ 30 cm (ST-VI) 6.7 1576 ✕ 1976 10 2364 ✕ 2964
18 ✕ 24 cm (ST-VI) 10 1770 ✕ 2370 10 1770 ✕ 2370
24 ✕ 30 cm (HR-V) 10 2364 ✕ 2964 10 2364 ✕ 2964
18 ✕ 24 cm (HR-V) 10 1770 ✕ 2370 10 1770 ✕ 2370

FCR standard cassette with or without


lead foil backside.

FCR long view cassette for Scoliosis

This equipment is a Class 1 laser product (IEC60825).


Specifications are subject to change without notice.
All brand names or trademarks are the property of their respective owners.
In some countries, regulatory approval may be required to import medical devices.
For the availability of these products, please contact your local sales representatives.

http://www.fujifilm.com/products/medical/
26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPAN
http://www.fujifilm.com/products/medical/ Ref. No. XB-970E (SK·09·11·F1120·F9711) Printed in Japan ©2009 FUJIFILM Corporation
An industry-standard
digital imaging technology Compact Size

to suit your diagnostic needs. Operator convenience and versatility benefit from the exterior
dimensions, including a small footprint of 655 mm ✕ 740 mm.

1480 mm
Fujifilm’s new XG5000 has been engineered and designed for even greater user-friendliness
and efficiency, making it the standard of excellence in the FCR reader line-up.

mm
Incorporating renowned Fuji image processing technology to yield wide-latitude images of

740
high resolution and consistently high image quality, the XG5000’s compact size and remarkable
655 mm
operator convenience make it the reader of choice for general-purpose diagnostic needs.

A Multi-purpose FCR Enhanced Image Processing Quick Image Delivery Convenient and Efficient

“Image Intelligence™” – a set of sophisticated Connected to the CR Console, 14” ✕ 17” images in 10-pixel A convenient stacker
digital image-processing software technologies resolution are viewable in only 39 seconds from the time of accommodating four-cassette
available through the CR Console – processes exposure, enabling quick turn-around. When printing on stackers at once minimizes
image data and optimizes final output. the DRYPIX 7000, prints are available within 110 seconds of operator wait time thus
a cassette insertion. enabling the processing of
FNC Flexible Noise Control up to 103 Imaging Plates (IP)
Provides a non-grainy image by mainly isolating and suppressing (35 ✕ 43 cm) per hour.
the noise for the signal.

MFP Multi-frequency Processing (option)*


As an optional software applicable for all types of FCR imaging, 39 sec.
MFP is an improved version which uses frequency enhancement to Enhanced Inter-operability Through CR Console
provide more diagnostic data from a single exposure image, using
Fujifilm’s renowned Dynamic Range Control (DRC).
MFP improves visibility of both dense and peripheral tissue by CR Console
Standardized control of image
simultaneously applying edge enhancement processing to small plus data processing through
and large structures within an image.
the CR Console ensures
* Image processing requires the use of FCR CR Console Plus
Compact in overall dimensions yet extremely powerful in consistently optimized “first-up”
specified applications, the XG5000 can provide chest, GPR Grid Pattern Removal (option) images, reducing time for image
spine, head and other plain x-ray imaging, as well as Removes the stationary grid patterns thus preventing Moiré from adjustment. Image quality is
spinal canal, urinary organ, and other contrast medium being generated resulting in easier diagnosis. (convenient for a
FCR XG5000
110 sec. consistent with other Fujifilm CR
x-ray imaging and x-ray tomography. cassette study) readers.
DRYPIX 7000
FUJIFILM FCR XG5000 Specifications
Standard Components: Number of Stackers: 4
• FCR XG5000 Image Reader (Model: CR-IR 362)
Reading Gray Scale: 12 bits
• AC power cord
Network: 10 Base T/100 Base TX
Other System Components (sold separately):
• CR Console Plus (sold separately) Dimensions (W ✕ D ✕ H): 655 ✕ 740 ✕ 1480mm (26” ✕ 29” ✕ 58”)
• Image Recorder : DRYPIX 4000 / 7000
Weight: 270 kg (595 lbs.)
• ID Card Writer
• FCR Data Management System Power Supply Conditions:
Single phase 50-60Hz
Supplies:
AC120-240V ±10%
Imaging Plate:
7A (max)
• ST-VI (Standard): 14” ✕ 17”, 14” ✕ 14”, 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24cm
• HR-V (High Resolution): 24 ✕ 30 cm, 18 ✕ 24 cm Environmental Conditions:
IP Cassette: • Operating Conditions:
• Type CC: 14” ✕ 17”, 14” ✕ 14”, 10” ✕ 12”, 8” ✕ 10”, 24 ✕ 30 cm, 18 ✕ 24 cm Temperature: 15-30°C
• Type LC: 35.4 ✕ 124.5cm, 35.4 ✕ 101.7cm, 35.4 ✕ 83.0cm, 25.2 ✕ 58.0cm, 24.0 ✕ 57.0cm Humidity: 40-80%RH (No dew condensation)
• Non-operating Conditions:
Time Required for IP Feed/Load: Temperature: 0-45°C
IP Type IP Size Required Time Humidity: 10-90%RH (No dew condensation)
ST-VI 14” ✕ 17” (35 ✕ 43 cm) Approx. 60 sec.
ST-VI 14” ✕ 14” (35 ✕ 35 cm) Approx. 54 sec.
ST-VI 10” ✕ 12” Approx. 50 sec. Dimensions Unit: mm (in.)
ST-VI 8” ✕ 10” Approx. 40 sec.
740 (29) 655 (26)
ST-VI 24 ✕ 30 cm Approx. 51 sec.
ST-VI 18 ✕ 24 cm Approx. 42 sec.
HR-V 24 ✕ 30 cm Approx. 65 sec.
HR-V 18 ✕ 24 cm Approx. 55 sec.

Processing Capacity
(in high-pixel density two-image output format):

1480 (58)
When connected to
IP Type IP Size
DRYPIX 7000/CR Console Plus
ST-VI 14” ✕ 17” (35 ✕ 43 cm) Approx. 103 IPs/hr.
ST-VI 14” ✕ 14” (35 ✕ 35 cm) Approx. 120 IPs/hr.
ST-VI 10” ✕ 12” Approx. 128 IPs/hr.
ST-VI 8” ✕ 10” Approx. 165 IPs/hr.
ST-VI 24 ✕ 30 cm Approx. 128 IPs/hr.
ST-VI 18 ✕ 24 cm Approx. 165 IPs/hr.
HR-V 24 ✕ 30 cm Approx. 90 IPs/hr.
HR-V 18 ✕ 24 cm Approx. 110 IPs/hr.

Time to Print on DRYPIX 7000 through network via CR Console:


Approx. 110 sec.

Image Reading (Image output is via CR Console)


IP Cassette with Imaging Plate
Standard Pixel-density High Pixel-density
Reading Size Type LC Type CC
Pixels/mm Number of Pixels Pixels/mm Number of Pixels

14” ✕ 17” (35 ✕ 43 cm) 5 1760 ✕ 2140 10 3520 ✕ 4280


14” ✕ 14” (35 ✕ 35 cm) 5 1760 ✕ 1760 10 3520 ✕ 3520
10” ✕ 12” 6.7 1670 ✕ 2010 10 2505 ✕ 3015
8” ✕ 10” 10 2000 ✕ 2510 10 2000 ✕ 2510
24 ✕ 30 cm (ST-VI) 6.7 1576 ✕ 1976 10 2364 ✕ 2964
18 ✕ 24 cm (ST-VI) 10 1770 ✕ 2370 10 1770 ✕ 2370
24 ✕ 30 cm (HR-V) 10 2364 ✕ 2964 10 2364 ✕ 2964
18 ✕ 24 cm (HR-V) 10 1770 ✕ 2370 10 1770 ✕ 2370

FCR standard cassette with or without


lead foil backside.

FCR long view cassette for Scoliosis

This equipment is a Class 1 laser product (IEC60825).


Specifications are subject to change without notice.
All brand names or trademarks are the property of their respective owners.
In some countries, regulatory approval may be required to import medical devices.
For the availability of these products, please contact your local sales representatives.

26-30, NISHIAZABU 2-CHOME, MINATO-KU, TOKYO 106-8620, JAPAN


http://www.fujifilm.com/products/medical/ Ref. No. XB-970ER (SK·10·03·F1120·F9711) Printed in Japan ©2009 FUJIFILM Corporation