Professional Documents
Culture Documents
BOLL Filter Maintenance Scheme
BOLL Filter Maintenance Scheme
BOLL Filter Maintenance Scheme
波勒过滤器维护步骤
2-3:Open the drain valve, and let see water comes out of filter, and then close this valve
打开滤器的放残阀,先把滤器内部的海水泄放。然后,关闭这个阀门。
2-4:Open the fresh water filling valve, until the water comes out of manual vent valve or
blind flange, then close the filling valve.
打开滤器的淡水加注阀,直到有水放气阀或者从松开盲板法兰处漏出。
Note:The best fresh water should be soft water (the fresh water from onboard fresh
water generator is recommended.)
注:最好加注软水(推荐使用如船舶造水机生产的淡水)
2-5:Close the fresh water filling valve.
关闭淡水加注阀。
3-2:Carry out ‘drain sea water, fill fresh water’ as item 2-1 to 2-5 mentioned.
再执行一次“放海水,充淡水”的动作。详见 2-1 到 2-5。
长期停用(超过三个月不使用):
1. Take out all filter candles and clean them by fresh water
把全部滤芯拿出,用淡水冲洗干净。
2. Dry the element by compressed air or by naturally drying.
再压缩空气把滤芯吹干,或者让滤芯自然风干。
3. If all filter valves have no leakage, the filter candles can be put back into filter, and make
sure the filter inside is dry.
If some valve is leaking water, then filter candles have to be safely stored until next
operation is requested.
如果滤器所有阀门都没有任何泄漏,可以把滤芯装回滤器内。保证滤器内部干燥。
如果滤器有阀门不关严,请把滤芯妥善保管,直到下次使用前,才装复。