Body Fever Scanner

Field Application Setup


Suitable for Security and Epidemic Prevention Personnel
Body Fever Scanner Install Recommendation

∙ Camera height needs to be about 180 ~ ∙ Best to setup the camera at a tilting
200cm higher than average people down angle of 10~15°
height

Note: After the system has been


setup, please do not move the
system. Any relocation of the
camera will require system resetting.
Fast Screening Walkway Setup

• The fast screening passage planning is based on


guiding the flow of people through the "single
lane and one-way" channel. The basic principle is
to make the flow of people reach a fixed distance
point (detection area) from the camera to make
sure that all the people are screened.

• The distance between this detection point /area


and the camera is the "detection distance", and
this distance must be within 2 meters. The closer
the better, but need to be done without
compromising the convenience of test subjects
and the speed of people flow. In some cases, you
can shorten the distance to 1 meter to increase
the surface area of the face being photographed if
needed.
Installation Location Survey

• Avoid sources of heat other than human in the scene.

• Must avoid direct sunlight and maintain constant ambient temperature


environment is preferred

• Arranging moving walkway plan

4
Equipment Installation Requirement

• PC Computer: CPU Intel I5 and above , 4GB RAM, 500GB space for system software, 1TB for
recording data storage, Screen, WIN10 OS, Keyboard/Mouse

• Speaker:1 set for alarm sound

• Network Cable:1 pcs (length depend on the PC and the camera distance)

• Power: Extension cord x 1

• Table: for stand, computer screen, keyboard / mouse.

• Stand: 1/4 "standard connection screw, camera height needs to be about 180 ~ 200cm higher
than average people height

• Curtain:If installed outdoors, avoid background temperature

• Queuing railings:Allows the camera to detect body temperature at a fixed distance

5
Software installation

• Please prepare the computer which you get from the


sellers to match below requirements before you start to
install the T-Guard software.
• Operation System: Windows 7/8/10
• CPU: Intel Core i7, 2.2GHz, 4 cores 8 threads above
• RAM:8GB
• HDD: C:/64GB above. D:/1TB above (D:/ disk is necessary
for recording)

• After the installation wizard process you would find


the shortcut on the desktop finally. Before double
clicking it to open T-Guard software, please right-click
mouse (Properties) to enable the [Run this program
as an administrator] option first.

6
Main Console interface

• Open T-Guard to enter the main console interface:

7
System Setup Management

• Click button to entering the system setup interface.

8
Add IP-Camera

• Click “IP-Camera” sheet


• Scanning area network devices: The system can 1
automatically search for cameras that are supported 2
and located on the same network segment.
• Manually specify the IP address: If you have a
camera device with a known IP, you can add it
manually. 3
• Add IP camera: The camera supported by this system
automatically appears in the label menu. After
entering the relevant information, the management 5
list can be established.
• Add the selected device from the above table: Add 4
the searched camera to the list and the camera will
appear in the Camera List column on the main
operating interface of the system.
• Currently managed devices: After re-entering the
system, the camera on the main operating interface
of the system will also appear in the managed device
bar.
• Name, auto-monitor, auto-login, and video monitoring
profile settings can be made for the selected camera.
Click Save to save the settings parameters.

9
Alarm Linkage Setup—Alarm Sound
In the setup at the bottom right corner of the T-Guard main menu,

1
set the alarm linkage in order to effectively and quickly identify the
triggered hot target.

• After entering Setup, select "Alarm linkage settings", and add the new one → Heat source
event → Alarm sound → Alarm sound file (select the built-in sound file or import it
yourself), and then press OK → Save to complete the setting.

2
• Note that the
(Repeat Play) 6
option ( 8 ) in 5
step 4 needs to
4
be unchecked.
3

7 C:\Program Files (x86)\VMS\wav


11

10 9
10
Alarm Linkage Setup—Photo Capture

• After entering Setup menu, select "Alarm linkage settings", and then click Add → Heat
source event → Take photo → Link Camera, then click the corresponding device, and then
press OK → Apply to complete the setting.

5
4

8
9 7
11
Alarm Linkage Setup—Photo Capture

• Click "System Settings", check "Show photos taken in the lower right corner of the lens"
below, and uncheck "Enable watchdog", press Apply and close the window when finished.

4 5

12
Thermal Image Setup—Overlay Image Setting
• This function is used to make the visible camera image and the thermal image overlap and
display on the same screen.

• Move the cursor to the position of the image display screen, right-click, and select "Thermal
Image Setting" from the menu

• As shown in the figure below, move the cursor over the thermal imager and hold it down,
then drag the thermal image to superimpose the visible image

• In order to clearly identify the person being detected, you must move the pull bar of
"Thermal Picture Filter" and "Superimposed Transparency" to the far left
Thermal Image

Visible camera Image


8
Thermal Image Setup—Image Setup

• After entering the setting menu of the thermal image, you can refer to the setting methods
and parameters in the red box in the figure below to check and fill in the values.

14
Effective Screening Temperature Value Setting
• In order to effectively screen those suspected of
having a fever, the system compares the actual
body temperature before the rush hour in the
morning, noon, and night, as the basis for
setting the screening temperature.

• The operator stands in the "detection area" for


1 to 2 minutes, and observes the middle value
of the highest temperature data of the forehead
(the temperature data may fluctuate between ±
0.5 ° C). Then take your temperature with a
forehead thermometer to obtain your body
temperature data. If the value obtained by the
Body Fever Scanner is higher than the forehead
thermometer, then adjust the critical value of
heat source to 38 ℃. Otherwise, if it is lower
than the measured value, the critical value of
the heat source temperature is set to 37.5 ℃ to
activate the alarm.
Thermal Image Setup—Detection Area Select

• The red square in the "Select Detection Area" screen indicates that when a person or
object passes through the area, the temperature information is collected.

• Click the left mouse button on the


screen to increase the red square,
and right click to cancel the red
square.

• Before drawing the detection area,


you must have a person stand in the
detection area, and then point and
right-click in sequence → thermal
image setting → thermal image
setting → select the detection area,
and click the left and right mouse
buttons to complete the detection
region settings.

16
System Setup—Parameter Setting Backup

• When the T-Guard software version needs to be reinstalled due to an update, the
previously set configuration files and parameters can be backed up by exporting the setting.

• Select "System Settings" in the


1
Setup menu, click "Save all
configurations to a file" below,
3
and select a file storage location
in the pop-up window. After
confirming, press "Archive" to
complete the backup operation.

17
System Setup—Parameter Setting Import

• As shown in the figure on the


1
right, when you need to
import the configuration file,
you can "Import all 3
configurations from the
backup file" in "System
4
Settings", select the file
location of the configuration
file in the pop-up window 5
and press Open. After
launching the T-Guard
software, complete the 2
configuration file import.

18
Thank You!