KEY PLAN & SECTION

500 3620 500 570

Y10@150C/C 3500

SLAB
TOP BOTH WAYS

150
100MM THK PCC.M15 3000
Y10@150C/C 500

100
GROUND FLOOR TOP BOTH WAYS

410
+0.000M LEVEL

RCC PEDESTAL

275

410
EARTH/STONE FILLED GROUND FLOOR
100MM THK PCC.M15
600

+0.000M LEVEL STRUCTURAL REFERENCE DRAWINGS


375
325

EARTH/STONE FILLED

175
PB1 NO. DESCRIPTION

1000
PB2 FOUNDATION DRAWING FOR FULLY ELECTRONIC

325
RWT/12X3 WEIGHT BRIDGE.CAP.50/60 TON/(12X3)

1500
100 THK PCC. 1122-S1 FOR GENERAL ARRANGEMENT DRAWING
Y12@150C/C Y12@150C/C
230 THK RUBBLE SOILING BOTTOM BOTH WAYS TOP BOTH WAYS 100 THK PCC. 1122-S2 PLAN AND SECTION DETAIL AT RAFT & FOUNDATION LVL

400
WELL COMPACTED SOIL. 230 THK RUBBLE SOILING
Y12@150C/C Y12@150C/C
BOTTOM BOTH WAYS SECTION 3-3 TOP BOTH WAYS WELL COMPACTED SOIL.
SECTION 2-2 SCALE 1:30
SCALE 1:30
100 THK PCC.
Y10@120C/C NOTES
TOP & BOTTOM 230 THK RUBBLE SOILING
BOTH WAYS
WELL COMPACTED SOIL. 1) THIS DRAWING SHOULD NOT BE USED FOR EXECUTION
UNLESS IT IS STAMPED AND SIGNED
2) THIS DRAWING MUST BE READ ALONG WITH THE
WORKING / ARCHITECTURAL DRAWING
3150
3) THIS DRAWING SHOULD NOT BE SCALED OFF ONLY
WRITTEN DIMENSIONS SHOULD BE FOLLOWED
B1(230X450) B1(230X450) 4) THIS DRAWING IS PROPERTY OF " SAHANI ASSOCIATES
CONSULTANTS " & SHALL NOT BE REPRODUCED OR
USED WITHOUT WRITTEN PERMISSION OF THIS OFFICE.
5000
4770 RCC-NOTES

C7 RB1(230X450) C8 1. READ THIS DRAWING IN CONJUNCTION WITH RELEVANT


B2(230X450) ARCHITECTURAL DRAWING
1000

2. FOR COLUMN CENTER REFER ARCHITECTURAL COLUMN


8-Y16 8-Y16
350 CENTER LINE DRAWING.
1500

Y8@150C/C Y8@150C/C 3. CONTRACTOR SHALL CARRY ALL FOUNDATIONS TO SOUND,

RB2(230X350)

RB2(230X350)
UNDISTURBED STRATA HAVING MINIMUM SAFE BEARING
RS1 2
CAPACITY OF 25 T/M. DEPTH AS PER SOIL REPORT.

2500
2270
400

4. CONCRETE GRADE SHALL BE M25 UNLESS OTHERWISE NOTED.


5. REINFORCEMENT GRADE SHALL BE Fe-500 UNLESS
OTHERWISE NOTED.
SECTION 4-4
SCALE 1:30 100 THK PCC. 6. COVER TO REINFORCEMENT SHALL BE FOLLOWS
Y10@120C/C
C9 C10
230 THK RUBBLE SOILING FOOTING ------------------------------------ 65MM
TOP & BOTTOM
BOTH WAYS WELL COMPACTED SOIL. COLUMN BELOW GROUND -------------- 65MM
RB1(230X450)
COLUMN ABOVE GROUND --------------- 40MM
BEAM ----------------------------------------- 30MM.
SLAB ------------------------------------------ 20MM.
PLAN AT ROOF LEVEL OF (GATE HOUSE) 7. ALL DIMENSIONS ARE IN MM UNLESS OTHERWISE NOTED.
SCALE 1:50

SCHEDULE OF FOOTINGS & COLUMNS :- SCHEDULE OF ROOF BEAMS.


NOTE : ALL COLUMN LINK SETS SHALL BE 8 @100C/C AND 150C/C AS PER TYPICAL DETAILS OF COLUMN & LAP BEAM SIZE BOTTOM STEEL TOP STEEL STIRRUPS
NO.
FOOTING DETAILS B D STR '1' CURTAIL'2'
EXTRA CONT. '3' LEFT
'4'
EXTRA RIGHT EXTRA
'5' 'X' 'Y' 'Z' REMARKS P1 01.07.19
WATER BOUND MACADAM REVISED
WITH 100MM PCC .M15 AKSHAY N.P.S

FOOTING REINFORCEMENT RB1 230 450 2-Y16 2-Y12 2-Y12 2-Y12 2-Y12 Y8@120C/C Y8@150C/C Y8@120C/C P0 24.06.19 FOR CONSTRUCTION AKSHAY N.P.S
SIZE REMARK
NOS. B0TTOM BARS TOP BARS RB2 230 350 2-Y16 - 2-Y12 1-Y12 1-Y12 Y8@120C/C Y8@150C/C Y8@120C/C REV. DATE DESCRIPTION DRN. CHK.
NO.

L B D d SHORT LONG SHORT LONG NOTE:- * PROVIDE 2-Y16 FACE BAR ON EACH FACE. REVISIONS
BARS BARS BARS BARS
DRAWING CATEGORY DRAWING PURPOSE
F1 1200 1200 400 - Y10@120C/C Y10@120C/C Y10@120C/C Y10@120C/C
SCHEDULE OF ROOF SLAB CONCEPT FOR INFORMATION
COMBINE SCHEMATIC FOR TENDER PURPOSE
F2 1975 1727 450 - Y10@120C/C Y10@120C/C Y10@120C/C Y10@120C/C REINFORCEMENT
FOOTING SLAB THICKNESS REMARK TENDER
FOR APPROVAL
COMBINE MARKED MAIN DISTRIBUTION SURVEY DRAWING
FOR CONSTRUCTION
F3 1650 1221 450 - Y10@120C/C Y10@120C/C Y10@120C/C Y10@120C/C FOOTING Y8@120C/C Y8@200C/C APPROVAL DRAWING
RS1 120 ONE WAY WORKING DRAWING
ALT BENT UP -
COMBINE AS BUILT
F4 1725 1469 450 - Y10@120C/C Y10@120C/C Y10@120C/C Y10@120C/C FOOTING NOTE:-FOR ONEWAY SLAB PROVIDE Y10@150C/C TOP BAR ON SHORT SPAN. CLIENT:- ANTONY LARA ENVIRO SOLUTIONS
PRIVATE LIMITED
PROJECT:- PROCESSING TREATMENT PUBLIC
DISPOSAL MUNICIPAL SOILED WASTE WITH
SCHEDULE OF PLINTH BEAMS. STATE OF ART WASTE ENERGY PLANT .
DRN. AKSHAY DRAWING TITLE
BEAM SIZE BOTTOM STEEL TOP STEEL STIRRUPS
DSN. N.P.S WEIGHT BRIDGE
NO.
STR '1' CURTAIL'2' CONT. '3' LEFT EXTRA RIGHT EXTRA PLAN AT ROOF LEVEL AND SECTION
B D EXTRA '4' '5' 'X' 'Y' 'Z' REMARKS CHK. N.P.S AT RAFT AND FOUNDATION LEVEL
-
PB1 230 450 2-Y16 2-Y16 2-Y12 2-Y16 2-Y16 Y8@120C/C Y8@150C/C Y8@120C/C SCALE AS SHOWN

PB2 230 450 2-Y16 2-Y16 2-Y12 2-Y16 2-Y16 Y8@120C/C Y8@150C/C Y8@120C/C DATE 24.06.19

PB3 230 450 2-Y16 2-Y12 2-Y12 2-Y12 2-Y12 Y8@120C/C Y8@150C/C Y8@120C/C DRG. NO. 1122-S13A
PB4 230 350 2-Y16 - 2-Y12 1-Y12 1-Y12 Y8@120C/C Y8@150C/C Y8@120C/C
SAHANI ASSOCIATES

SHEET-A2
AMOL APARTMENTS, 501, BHAGOJI KEER ROAD,
NOTE:- * PROVIDE 2-Y16 FACE BAR ON EACH FACE. MAHIM, MUMBAI-400 016, TELEFAX- 24443605, TEL.-24455953