Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

4/19/22, 2:27 PM Numerical Simulation of the Effect of Outlet Position of Air Duct on the Construction Ventilation of the Tunnel

Login | Sign Up | Oriprobe Inc. | Feed

Home Journals Order TOC Alerts Subscription Products & Services Pricing FAQ About

Journal Articles Laws/Policies/Regulations Companies/Products


Title, abstract, keywords: Combined Search Pay per View through On Demand Search
Advanced Search

Related Articles
Numerical Simulation of the Effect of Outlet Position of Air Duct on the
Construction Ventilation of the Tunnel Numerical Simulation of the Effect
of Outlet Position[Year
of Air 2014,Issue
Duct on the 2]

Author(s): Fang Yong, Peng Pei, Zhao Zicheng, Zhou Chaoyue, Key Laboratory of Transportation Tunnel Engineering, Ministry of Numerical simulation of the effect
Education, Southwest Jiaotong University, School of Civil Engineering, Southwest Jiaotong University, China Railway Eryuan
Engineering Group Co., Ltd. of coupling support of 2009,Issue 3]
[Year
Pages: 468-473
Year: 2014 Issue: 2 Numerical simulation about the
Journal: Chinese Journal of Underground Space and Engineering effect of fixture on[Year
the welding stress4]
2008,Issue
Keyword: highway tunnel; forced ventilation; numerical simulation; CFD;
Abstract: To study the impact of the outlet position of air duct on construction ventilation of highway tunnel,a three-dimensional model of Numerical simulation on the
the tunnel is built and simulated numerically with the software Fluent based on fluid dynamics theory. A comparative analysis is made on
five kinds of distance between the air duct outlet and heading face and also four kinds of location of air duct,the impact of distance shortterm failure of electromotor
[Year axe1]
2009,Issue
between the air duct outlet and heading face and the attachment of the duct on the flow velocity and effective distance is analyzed. The
impact on local resistant wind pressure for different position of the air duct outlet was further explored. The simulation results show that Numerical Simulation of the Eddy
under the same entry speed conditions,the closer the duct was placed to the heading face or attached to the wall of tunnel,the bigger Current Effects on[Year
the Arc Splitting 11]
2012,Issue
velocity gradient of jet and the better ventilation effects there would be; The value of local pressure loss is bigger when the distance
between the air duct outlet and heading face is shorter. Dust Diffusion Simulation in the
Third Layer Construction of
[Year 2009,Issue 2]
Numerical Investigation of the
Effects of Wind Tunnel
[Year Model
2010,Issue 4]
Numerical Simulation of Water
Exchange Characteristics of the
[Year 2009,Issue 2]
Numerical Simulation of the
SelfHeating Effect[Year
Induced by
2012,Issue 2]
Effect of Reaction Layers on the
Residual Stress of the Brazed
[Year TiC 2]
2009,Issue

Tel:1-519-977 9050 | Email:info@oriprobe.com


Copyright© 2022 Oriprobe Information Services, Inc. All rights reserved.

caod.oriprobe.com/articles/41721016/Numerical_Simulation_of_the_Effect_of_Outlet_Position_of_Air_Duct_on_t.htm 1/1

You might also like