Professional Documents
Culture Documents
45m WUV 600kw轴发完工资料(20170526)
45m WUV 600kw轴发完工资料(20170526)
Ltd
文件清单
File List
发电机数据单
Data of the Alternator
短路电流计算参数
Short-circuit Current Calculation Parameters
DG1~2 SG1~2 EG
Sgr(kVA) 340 600 90
Ur(V) 440 440 440
f(HZ) 60 60 60
Xd''( Xd''( 12.5% 11.6% 8.2%
Xd'( Xd'( 17.8% 14.4% 13.6%
Xd( Xd( 308.0% 265.0% 242.0%
Ra(mohm Ra(mohm 7.6 3.1 3.9
Ra( Ra( 1.70% 1.20% 2.30%
Td''(ms) Td''(ms) 10 10 10
Td'(ms) Td'(ms) 143 124 166
Tdc(ms) Tdc(ms) 15 15 15
Ikd(kA)
A 4184 9097 1249
A 2455 5628 734
A 3022 6629 1040
In A 558 984 148
1 of 1
FujianMingyang Marine Co,.Ltd
发电机外形图
Alternator Outline Drawing
发电机扭振计算参数
Alternator TVC Parameters
.发电机接线图
Electrical Wiring Diagram
Induit-Armature
STATOR
+ -
Ponts tournants S2 P2
Inducteur Rotating rectifiers TI04
Exciter field T5- V2 T6- W2
S1 P1
noir - black
T4- U2
rouge - red
OPTION - OPTIONAL
5+ 6 - 9 10 11 12 32 8 7
T I // - // CT
P1 P2 P3 Couplage Etoile -Y- Star connexion
4 Poles : In/4 / 1 A
9 0 1
9 2
8
7 3
60 Hz 6 54
49.1 46.2 3 PH
50.2 47.2
50 Hz 49.1 46.2 Y
50.2 47.2
Noir/black T1 T1
FAST NORMAL
Noir/black T2 T2
Noir/black T3 T3
FAST NORMAL 170 - 240 V (50/60 HZ) Bleu/blue N
340 - 520 V (50/60 Hz) Blanc/white
P4
8
7 8 --> S1 Pour sens de rotation anti-horaire
7 --> S2 For Anticlockwise rotation
Option- Optional : 1k ou/or 470 -3W
HR/CW
Ajustage tension ext»rieur (enlever ST)
Remote Voltage trimmer (remove ST )
DESEXCITATION / DESENERGIZING
Bob. auxiliaires
9 12 Aux. windings
OUVRIR E 01
R 450 OPEN E 01
X1
Z2
SCH 000 ST 170 Nè de C.T Dess: CR V»rif: EV Date : 22/04/10 Usine de Sillac, bd Marcellin Leroy
16015 ANGOULEME - CEDEX
d
SCHEMA DES CONNEXIONS INTERNES
c
b CONNECTION DIAGRAM Nè:
a cr»ation 10 - 167 a
101
101
102
102
103 white-blanc
103
104 red-rouge
104
104 red-rouge
104
105 white-blanc
105
106 red-rouge
106
106 red-rouge
106
107 white-blanc
107
108 red-rouge
108
108 red-rouge
108
109 white-blanc
109
110 red-rouge
110
110 red-rouge
110
111 white-blanc
111
112 red-rouge
112
112 red-rouge
112
113 white-blanc
113
114 red-rouge
114
114 red-rouge
114
121 white-blanc
121
122 red-rouge
122
122 red-rouge
122
123 white-blanc
123
124 red-rouge
124
124 red-rouge
124
FujianMingyang Marine Co,.Ltd
船厂接口图
Interface Diagram For Shipyard
-RP
-
+
5
6
9 10 11 12 U1 V1 W1 U1 V1 W1 DE NDE
ST 7
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8 9 10 11 12 23 24
A
驱动端轴承温度
Z1
60 Hz X1
U相绕组温度
V相绕组温度
W相绕组温度
U相绕组温度
V相绕组温度
W相绕组温度
X1
Z2
空间加热器电源
Z2
E +
50 Hz
E -
0V
110V
220V
Evlernel petenhometer S1 S2 380V
P4
1 2 3 4 5
Note:
Winding Temp.High Alarm Set Value :155°C
Winding Temp.Too High (Trip) Set Value:160°C
Bearing Temp.High Alarm Set Value : 90°C
Bearing Temp.Too High (Trip) Set Value: 95°C
制图
船 厂
45M MUV 600KW Shaft Generator Alternator Shipyard Interface
批准
审核 A3
制造商
设计 工 程 号 日 期 图 纸 比例 重 量
修改 日期
FujianMingyang Marine Co,.Ltd
手动调压电位器
Voltage Adjust Potentialmeter