 Press “Menu” key long press to enter into parameter setting.


 Display Will Show “---FUN”.
 Press “Zero” Key until display will show “---CAL”.
 Press “Tare” Key to enter into main calibration menu.
 Display will show “CAL 1”.
 Press “Zero” key until display will show “CAL 3”.
Note -“CAL 3” stores the previous calibration point.
 Press “Tare” Key to enter into menu.
 Display will show the previous cal point. Long press “Manu” key to delete the
Calibration point. Delete all calibration points.
 After deleting the all calibration point display will show “CAL 4”.
 Press “Zero” key until display will show the “CAL 1”.
 Press “Tare” key to enter into Calibration setting.
 Display will show “--CP 1--”(Zero Calibration )for few second and shift to display
reading “0000.0”.
 Make sure that weighing hopper is empty and long press “Menu” key to store the
zero calibration point.
 Display will show the “--CP 2--” (First Span Calibration point.) for few second and
shift to display reading “0000.0”.
 Using alternate function of “Zero” and “Tare” key set weight which is going to use
for calibration.

1|Page
Document Name – CALIBRATION PROCEDURE OF
SGM 700 WEIGHING HOPPER 1,2,3,4,5,6

Alternate Function description-



Sr. No Key’s Alternate function
1 Zero Key to increment the digit.
2 Tare Key to shift the digit.

 After set the weight in display, put weight on weighing hopper.


 Long press “Menu” key to stored the span calibration point.
 Display will show “CAL 2”.
 Press “Menu” key 2 times to exit from the menu.
 Display will show weight display.