Professional Documents
Culture Documents
Sitrans th100 - 2024
Sitrans th100 - 2024
Sitrans th100 - 2024
Overview
Temperature transmitters
Temperature measurement
Compact and head transmitters / SITRANS TH100 (4 to 20 mA, Pt100)
Temperature transmitters
Compact and head transmitters / SITRANS TH100 (4 to 20 mA, Pt100)
Overview Benefits
• Transmitter with 2-wire system
• Mounting in connection head, type B or larger or on DIN rail
• Programmable; as a result, the sensor connection, measuring
range and much more are programmable
• Intrinsically safe version for use in hazardous areas
Application
Function
Uref Input
Ic Pt100 Resistance thermometer
EMC_1 Input level with protective components
IC Constant current source
MUX Multiplexer
6
A/D Analog-digital converter
A/D
5 Output
Pt100 EMC_1 D/A Digital-analog converter
4
MUX U/I Voltage transformers, current
transformers, constant voltage
µC and reference voltage source
3
EMC_2 Output level with protective components
Uaux Auxiliary power supply
Iout Output current
D/A
Microcontroller
μC Linearization functions and storage
Uref of all data
+
U EMC_2 4 ... 20 mA Uaux, Iout
I
-
Temperature measurement
Temperature transmitters
Compact and head transmitters / SITRANS TH100 (4 to 20 mA, Pt100)
• Terminals IP00
• Pt100 (IEC 751) in the 3-wire connection
Certificates and approvals
• Measuring range: 0 … 100 °C (32 … 212 °C) ATEX explosion protection
• Fault current in the event of sensor breakage: 22.8 mA EC type-examination certificate DEKRA 21ATEX0033X /
DEKRA 21ATEX0034X
• Sensor offset: 0 °C (0 °F)
• Damping 0.0 s
Temperature measurement
Temperature transmitters
Compact and head transmitters / SITRANS TH100 (4 to 20 mA, Pt100)
20.8 (0.82)
• II 2 (1) G Ex ib [ia Ga] IIC T6...T4 Gb
• II 3 (1) G Ex ic [ia Ga] IIC T6...T4 Gc
• II 3 G Ex ic IIC T6...T4 Gc
• "Increased safety" type of protection • II 3 G Ex ec IIC T6...T4 Gc
• II 3 G Ex ec [ic] IIC T6...T4 Gc
• "Intrinsic dust safety" type of protection II 2 D Ex ia IIIC Db 44 (1.73) Internal diameter
Center hole 6.3 (0.25)
Explosion protection: FM for USA 4...20mA
• FM approval FM 3024169
Mounting screw
• Degrees of protection • IS / Cl I, II, III / Div 1 / GP ABCDEFG T6, T5,
T4 1 SIEMENS 2 M4x25
+ –
• Cl I / ZN 0 / AEx ia IIC T6, T5, T4 1 2
3-W
4 5
• FM approval FM 3024169C
Factory setting:
Temperature measurement
Temperature transmitters
Compact and head transmitters / SITRANS TH100 (4 to 20 mA, Pt100)
Circuit diagrams
3 6 3 6
3 6 3 6
3-W
3-W
4 5 4 5
4 5 4 5
Pt100 Pt100
4 5
4..20mA
4 5
1 SIEMENS 2
+ –
1 2
Pt100 6
5
6