Panel (pipeline) flow meter is also a rotor (or float) flow meter,
and the measuring tube is made of high-quality transparent organic
glass. It is mainly used in water purification treatment and
environmental protection projects, and can also be used in chemical,
petroleum, light industry, medicine, fertilizer, food, papermaking
and scientific research departments to measure the non-pulsating
flow of liquid single-phase.
Technical Parameter
Normal Spec GPM 0.1-1 0.2-2 1-5 1-10 2-16 2-26 4-40 6-60 10-100 50-150
Flow Range LPM 0.5-4 1-7 2-18 5-35 4-60 10-70 15-150 25-250 50-350 190-550
Accuracy ±4%FS
Repeatability ±0.25%FS
Range 10:01 10:01 5:1(10:1) 10:01 8:01 10:01 10:01 10:01 10:01 10:01
Maximum Pressure 1MPa/150psig
Maximum Temperature ≤90%/176℉
Basic Material Acrylic (organic glass)
Float Ball Material 316 stainless steel (≥150GPM 304stainless steel)
Guide Rod Material 316 stainless steel (≥150GPM 304stainless steel)
Fixing screw Material Copper
External pipe Material UPVC, ABS (Non-toxic), (Can also be made of stainless steel or nickel plated)
Upper and lower support F46
sleeve
O-Ring Silicone Rubber
The LZM series flow meter is a flow meter with plexiglass as the main body, used to measure the
single-phase non-arterial flow of liquid or gas. It is characterized by beautiful appearance, light weight, not
easily broken, and long lifespan.
Oxygen bar flowmeter, which is mainly used to detect and control the flow of oxygen, it is currently widely
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
E6 4-25
F1 1-5
F2 0.5-10 108 20 70 25 22 8
F3 2-10
G1 0-5
G2 1-5
115.5 20 90 13 22 8
G3 2-10
G4 0.5-14
LZT-4T/6T/8T Series
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Model A B C D E F
LZT-4T 94 27 21 14 14 70
LZT-6T 102 30 25 20 M18x1.5 77
LZT-8T 110 25 25 20 M18x1.5 80
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Model A B C D E F G H
LZT-10 157 32 150 35 25 60 25 110
LZT-15 175 32 168 35 25 76 25 127
LZT-25 236 45 228 46 33 100 37 265
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Model A B C D E F G H
LZT-15A 216 32 206 37 36 100 28 165
LZT-20A 223 39 220 44 42 100 37 165
LZT-25A 253 44 240 50 31 100 37 175
LZT-40A 265 62 250 62 33 100 52 170
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Model A B C D E F G H
LZT-10 157 32 150 35 25 60 25 110
LZT-15 175 32 168 35 25 76 25 127
LZT-25 236 45 228 46 33 100 37 265
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Model A B C D E F G H
LZT-15A 216 32 206 37 36 100 28 165
LZT-20A 223 39 220 44 42 100 37 165
LZT-25A 253 44 240 50 31 100 37 175
LZT-40A 265 62 250 62 33 100 52 170
Dimensions (mm)
Model A B C D E F G H I
LZT-15B 216 32 206 37 33 100 1/2" 165 30
LZT-20B 233 39 220 44 48 100 3/4" 165 32
LZT-25B 253 44 240 50 48 100 1" 175 40
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Dimensions (mm)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Installation size
Procurement Guide
1. LZT-XXSXXL: Long tube type
LZT-XXSXXD: Short tube type
2. Connection method: F: flange type, N: threaded connection, ❏Shen plug
3. Special requirements: if anti-corrosion type (guide rod lining F46) is required, then add /F46
LZB - 4 6 10 F Series
LZB-4,6,10F, anti-corrosion glass rotor flowmeter, some of the previous on the market are substitutes
made of the following stainless steel materials. They can’t really play a role in anti-corrosion. Therefore, we
have developed an anticorrosive flowmeter based on PTFE as the main material according to market needs,
and at the same time, we have overcome the difficulty of using anticorrosive materials to make flow
regulating valves. As a result, the small-diameter glass rotor flowmeter also has an anti-corrosion type.
This product has good corrosion resistance to a variety of strong acids (except hydrofluoric acid), strong
alkalis, oxidants, strong fluorinating agents, organic solvents and other corrosive gases and liquid flow
meters.
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Size (mm)
Model
A B C D1 D2 E F
LZB-4F4 160 204 234 (F)1/4"BSP Φ9 37.5x34 2-M6
LZB-6F4 160 204 234 (F)1/4"BSP Φ9 37.5x34 2-M6
LZB-10F4 160 208 238 (F)1/4"BSP Φ12 37.5x34 2-M6
LZB - 3 4 6 10 Series
The glass rotor flowmeter is used to measure the instantaneous flow of single-phase non-arterial liquid and
gas in the pipeline. Mainly used in chemical, petroleum, medical, fertilizer, food, sugar, paper, light
industry, textile, printing and dyeing, environmental protection and other industrial departments and
scientific research units. The anti-corrosion glass rotor flowmeter mainly uses PTFE high-grade
anticorrosive materials in contact with the medium. It is resistant to various strong acids (except
hydrofluoric acid), strong alkalis, oxidants, strong oxidation properties, organic solvents and other
corrosive gases and liquids. Good corrosion resistance in flow.
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Remarks: Those marked with "✭" is a special flow developed by the company,
Shape and installation dimensions of LZB-3,4,6,10 (including F, S, B type)
The LZB-WB flowmeter has 3 specifications, including Φ4Φ6Φ10. This flowmeter is suitable for measuring
a small range of flow. The product has the characteristics of small size, beautiful and light weight, and is
widely used in various analytical instruments, environmental protection equipment, and medical
equipment. And other experimental equipment.
WB type: flow meter with regulating valve, W type: without regulating valve
Size (mm)
Model
A B C D E
LZB-4WB 26x25 90 116 136 Φ9
LZB-6WB 26x25 90 116 136 Φ11.5
LZB-10WB 26x25 90 140 180 Φ11.5
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Nominal Diameter
Φ15 Φ25 Φ40 Φ50 Φ80 Φ100
(mm)
15-150 40-400 160-1600 400-4000 1-10m³/h 5-25m³/h
Liquid
25-250 60-600 250-2500 600-6000 1.6-16m³/h 8-40m³/h
l/m
Measuring 40-400 100-1000
Range 0.25-2.5 1-10 4-40 10-100 50-250 120-600
Gas
0.4-4 1.6-16 6-60 16-160 80-400 200-1000
m³/h
0.6-6 2.5-25
Precision (±%) 4 2.5 2.5 2.5 2.5 2.5
Operating
≤0.6 ≤0.6 ≤0.6 ≤0.6 ≤0.4 ≤0.4
pressure(Mpa)
The material of the parts of the anti-corrosion flowmeter in contact with the medium:
high borosilicate glass, the base, float, and guide rod are lined with
polytetrafluoroethylene, and the sealing ring is F46 diaphragm ring.
The stainless steel flowmeter with nominal diameter ≤10mm, the base material is
stainless steel, and the seal material is fluorine rubber.
Nominal Diameter
10 15 25 40 50 80
(mm)
6-105 7-31.5m³/h
Operating
≤1.0 ≤0.6 ≤0.6 ≤0.6 ≤0.6 ≤0.4
pressure(Mpa)
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
4-40
6.3-63
10-100
12-120
GA24-15 16-160
0.12-1.2 0.2-2
GA24-15F 20-200
0.3-3 0.4-4
VA/SA/FA10-15 25-250
15 0.5-5 0.6-6
VA/SA/FA10-15F 30-300
0.8-8 0.9-9
VA/SA/FA20-15 36-360
1.2-12 2-20
VA/SA/FA20-15F 40-400
··20℃~ + 60℃
46-460
or
63-630 1.5 ≤1.0MPa
··20℃~ +
65-650
120℃
75-750
40-400
50-500 1.6-16
GA24-25
63-630 2-20
GA24-25F
80-800 2.5-25
VA/SA/FA10-25
25 100-1000 3-30
VA/SA/FA10-25F
160-1600 4-40
VA/SA/FA20-25
200-2000 5-50
VA/SA/FA20-25F
250-2500 6-60
300-3000
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
GA24-40 160-1600
5-50
GA24-40F 200-2000
6-60
VA/SA/FA10-40 250-2500
40 8-80 ≤0.9MPa
VA/SA/FA10-40F 300-3000
9-90
VA/SA/FA20-40 400-4000
12-120
VA/SA/FA20-40F 500-5000
250-2500
GA24-50 300-3000
10-100
GA24-50F 400-4000
12-120
VA/SA/FA10-50 500-5000
50 16-160 ≤0.7MPa
VA/SA/FA10-50F 630-6300
20-200
VA/SA/FA20-50 800-8000
30-300
VA/SA/FA20-50F 1000-10000
1500-15000
✱ VA/SA/FA 10 Type Technical parameters and installation dimensions of glass rotor flowmeter
VA10 Pipe Thread Connection SA10 Hose Connection FA10 Flange Connection
Window
Model size Pipe Weight Weight Weight
L1 C L2 C D L3 C D E
axb thread (kg) (kg) (kg)
15 408 53 1/2"BSP 1.2 400 Φ13.5 Φ44 1.5 Φ65 Φ95 1.5
26x230 4-Φ14
25 414 75 1"BSP 1.5 Φ27 Φ65 2 Φ85 Φ115 2
320
40 40x230 428 92 1/2"BSP 2 450 Φ44 Φ80 3 Φ110 Φ145 3
4-Φ18
50 50x230 431 116 2"BSP 3.5 Φ53 Φ103 5 Φ125 Φ160 5
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
The casing of this series of flowmeters is bright stainless steel, and the interface connection has three
specifications: internal thread, loose flange and sanitary end, which is beautiful and practical, and light in
weight.
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
4-40 0.12-1.2
6-60 0.3-3
This series of flowmeters has the advantages of high sensitivity, wide measuring
range, small pressure loss, and convenient use and maintenance. Generally used
to measure low pressure, high temperature, transparent liquid or gas without
suspended particles, widely used in petroleum, chemical, electronics,
environmental protection, electric power, medicine and other industrial fields.
30-300 10-100
15 60-600 20-200
80-800 25-250
90-900 20-200
20 120-1200 30-300 ≤0.8
180-1800 50-500
180-1800 50-500
25 300-3000 100-1000
460-4600 150-1500
480-4800 200-2000
32 600-6000 250-2500
720-7200 300-3000
1-10m³/h 18-180Mn/h
40 1.2-12m³/h 20-200Mn/h ≤0.6
1.5-15m³/h 25-250Mn/h
1.2-12m³/h 20-200Mn/h
50 1.5-15m³/h 25-250Mn/h
1.8-18m³/h 30-300Mn/h
1.8-18m³/h 20-200Mn/h
65 3-30m³/h 35-350Mn/h
4-40m³/h 40-400Mn/h
4-40m³/h 40-400Mn/h
80 5-50m³/h 50-500Mn/h ≤0.4
6-60m³/h 60-600Mn/h
6-60m³/h 60-600Mn/h
100 7-70m³/h 70-700Mn/h
10-100m³/h 90-900Mn/h
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
Working principle: The float flowmeter with alarm switch uses the bistable magnetic function of the
magnetic control arm to open and close the contacts with the magnetic float, and cooperate with the relay
and other components to meet the requirements of sound and light alarms.
Function and application: BJ01 upper alarm switch, BJ02 lower alarm switch, BJ01 and BJ02 alarm switches
can send out signals at any flow value of maximum, middle and minimum. The alarm switch is installed on
a slidable track, select the desired position, when the magnetic float reaches or exceeds the switch position,
it will send out a signal. At this time, the internal contact opens or closes.
Technical parameters: Working voltage: ≤DC100W or AC100V Working current: ≤0.5A Constant current
when switching: ≤0.3A, working temperature: 0℃~+55℃, protection level: IP65 (open or closed position)
≤4mm
Note: 1. When installing, try to keep away from equipment that interferes with external magnetic fields,
such as large motors. 2. The fluid medium must not contain ferromagnetic impurities. 3. There should be
no vibration when installed in the pipeline to prevent malfunction of switch contacts.
5-50l/h
10-100l/h 10-100l/h
16-160l/h 16-160l/h
LZS-15 15 25-250l/h 25-250l/h
40-400l/h 40-400l/h
60-600l/h 60-600l/h
100-1000l/h
100-1000l/h
100-1000l/h
160-1600l/h
LZS-25 25 160-1600l/h
4-40l/min
250-2500l/h
250-2500l/h
4 0-50 ≤0.6
0.4-4m³/h
LZS-32 32
0.6-6m³/h
0.4-4m³/h
0.6-6m³/h 1-10m³/h
LZS-50 50
1-10m³/h 1.6-16m³/h
1.6-16m³/h
2.5-15m³/h
5-25m³/h
LZS-60 62
8-40m³/h
12-60m³/h
Remarks: LZS-100,125,150 specification flowmeter with alarm switch can be customized
Brotherfiltration Equipment Trading(wuhan)Co.,ltd info@brotherfiltration.com 0086 27 8399 2898
✱ LZB- Series Technical parameters of glass rotor flowmeter with alarm switch
Model LZB-6 LZB-10 LZB-15 LZB-25
✱ LZB- Series Technical parameters of glass rotor flowmeter with alarm switch