LIFE SHEET PROTECTIVE ELEMENTS AND EQUIPMENT FOR RISK PREVENTION

ELECTRIC

GIPHSE-04-PR-40FR

Land Gloves
Rug Pole x Detector
Laptops Dielectrics

COLLECTIVE DIELECTRIC
CLASS IV DIELECTRIC GLOVE AMOUNT 1
PROTECTION ELEMENT
BRAND REGELTEX MODEL GLE41-4/10
SERIES 923-053 923-054
FIRST 70071-0368 70071
INVENTORY CODE
DIELECTRIC 26-Nov-19 0369
TEST
Estimated Lifespan: 5
ACCESSORIES
Counted from:

MAKER REGELTEX PROVIDER'S NAME PERDOMO

SPECIFIC FUNCTION OF THE ELEMENT


Insulating or dielectric gloves are used against load centers, switches, blades, control panels, electric shocks in high voltage work which are found within an installation. The function of gloves is to
protect against electric shock or electric shock. Class 4, maximum operating voltage 36. 000 volts

Visually inspect the surfaces, interior and exterior, perform an air inflation test. Check that it is not wet or with perforations.
PRECAUTIONS:

Storage: gloves should remain in their packaging, neither compressed, folded, nor stored near a heat source; normal temperature 10/21 C Verification: before each use visually and then by
inflation
Classes 1,2,3 and 4: even just being stored, a glove cannot be used without having been verified after 6 months; the periods usual control They are between 30 and
60 days
The verifications are: an air inflation, a visual control while the glove is inflated and an electrical test according to the conditions of the rule. It is also recommended
a
inspection of the inside of the glove.

The date of the first use of the glove how the dates of the controls will be marked on the sites provided in the gloves.
Do not expose the glove to contact with oils, greases, acids or corrosive products. Clean with water only and soap clean with a cloth dry and let dry at
temperature atmosphere.
RECOMMENDATIONS: It should not be subjected to mechanical stress that generates tears. They should not be exposed to sunlight for long periods of time and should not be used on rough or uneven surfaces. Do not
subject them to sharp elements, these latex gloves must be used with leather overgloves for mechanical protection. It is recommended to use thin cotton gloves under the glove for greater comfort
and hygiene. RECORD
COMPLETE PHOTO KIT (Verify that you always have these 3 elements)

k — WN '

MANUALS AND OPERATION INSTRUCTIONS:


PHOTO RECORD wm 9 * ymy r
OPERATION INSTRUCTIONS
GUARANTEE LETTER
FUNCTION'S MANUAL

CERTIFICATE OF DIELECTRIC RIGIDITY x

CALIBRATION CERTIFICATE x
DATA SHEET x “ k THE—

Final Disposal Method:

3. CHECKLIST FOR PERIODIC REVIEW FOR THE POLE


months d year:
Conditions 1 2 3 4 5 6 7 8 9 10 11 12
1.General condition of the pole N/A
2.Security button status. N/A
3.Condition of the pole bodies. N/A
4.Condition of the hook or universal coupling. N/A
5.Security label status N/A

6.Monthly dielectric strength validation tests.


N/A
7.Semi-annual certified dielectric test √
Options: YEAH: √ NO: x Does not apply: N/A
ANDREA CASTAÑEDA

Inspection carried out by (First and Last Name)