Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 2

NOTIFY THE NATIONAL EMERGENCY SYSTEM

EMERGENCY AND THE


SHEET FOR SPECIFIC
THE AUTHORITIES OF HAZARDOUS
TRANSPORTATION OFMATERIALS:
MATERIALSFEDERAL PREVENTIVE
POLICE, FIREFIGHTERS, RED CROSS, ETC.
AND
PERSONAL PROTECTIVE EQUIPMENT AND MEANS DANGEROUS RESIDUES
SELF-CONTAINED EQUIPMENT, NEOPRENE GLOVES,3.-PRODUCT EQUIPMENT FOR FIREFIGHTER,6.GOGLES.
COMPLETENAME: TRANSPORTATION COMPANY
1.-COMPANY NAME AND ADDRESS OF THE
COMMERCIAL : DIETHYLENE GLYCOL
COMPANY: PETROQUÍMICA MORELOS SA
EJIDO PAJARITOS S/N CHEMICAL: DIHYDROXYDIETHYL-ETER
COL.GAVILAN DE ALLENDE
CP 96380 COATZACOALCOS VER.
MEXICO
4.-CLASSIFICATION: 7.- EMERGENCY TELEPHONES AND FAX:
• MAKER • IMPORTER
• USER • DISTRIBUTOR
• GENERATOR
2.-EMERGENCY NUMBERS 5. No. A OF THE MATERIAL: GUIDE NUMBER IS
AND FAX: 01 (9) 21-14000 127, 3271
01 (9) 21-14001

8.PHYSICAL STATE: LIQUID,


COLORLESS, PRACTICALLY 9.-PHYSICOCHEMICAL PROPERTIES:
ODORLESS
• FUSION TEMPERATURE (ºC): -10.0
•BOILING TEMPERATURE (ºC): 245.8 • AUTOIGNITION TEMPERATURE (ºC): 227
• FLASH TEMPERATURE (ºC): 143 • VAPOR DENSITY (air=1): 2.14
RELATIVE DENSITY: 1.1184
• • VAPOR PRESSURE (mmHg20ºC): 0.01
MOLECULAR WEIGHT : 106.1 g/gmol*
• • EXPLOSIBITY OR EXPLOSIVITY LIMITS
• EVAPORATION RATE (butyl acetate=1) LOWER: 2% UPPER: 12.3%
• SOLUBILITY IN WATER: SOLUBLE
• % VOLATIBILITY: --
• OTHER DATA:--

IN CASE OF AN ACCIDENT:
STOP THE ENGINE, PUT SIGNS IN THE DANGER AREA, REMOVE ANY UNNECESSARY PERSON FROM THE DANGER AREA.

RISKS ACTIONS
IF THIS HAPPENS DO THIS

15. EYE CONTACT: WASH WITH PLENTY OF WATER FOR AT LEAST 15 MIN
CONTACT WITH SKIN: WASH WITH PLENTY OF WATER FOR AT LEAST 15 MIN
INGESTION: CAUSE VOMITING
INHALATION: MOVE VICTIM TO FRESH AIR, GIVE ARTIFICIAL RESPIRATION IF APPROPRIATE.
REQUIRED REST
INTOXICATION/EXPOSURE

16. POLLUTION 17. PREVENT ENTRY INTO WATERWAYS, SEWERS, BASEMENTS OR CONFINED AREAS.

18.MEDICAL 19. ANTIDOTE (DOSE IF EXISTING): N/A


INFORMATION

20 21. ELIMINATE ALL SOURCES OF IGNITION, DO NOT TOUCH OR WALK OVER THE SPILLED MATERIAL,
STOP THE LEAK, IF YOU CAN DO SO WITHOUT RISK, A VAPOR SUPPRESSOR FOAM CAN BE USED TO
REDUCE VAPOR, IN LARGER SPILLS CONSIDER INITIAL EVACUATION A FAVOR WIND OF AT LEAST
300 M.
IN THE EVENT OF A LEAK OR
SPILL
22 23. EXTINGUISHING MEDIA: COOL CONTAINERS WATER FOG, FOAM, CO2 AND DRY CHEMICAL POWDER,
FIGHT THE FIRE FROM A MAXIMUM DISTANCE OR USE FIXED SUPPORTS FOR HOSE OR REGULATOR
CHIFLONS, COOL THE CONTAINERS WITH WATER JETS UNTIL LONG AFTER THE FIRE HAS BEEN
EXTINGUISHED.

FIRE / EXPLOSION

24.NAME SIGNA POSITIO PHONE


TURE N
25. THIS SHEET MUST BE IN AN ACCESSIBLE PLACE TO BE USED IN CASE OF EMERGENCY. IT MUST BE REQUIRED IN ITS ENTIRETY.