Professional Documents
Culture Documents
NCR Scrap2024-0031
NCR Scrap2024-0031
NCR Scrap2024-0031
DEPARTMENT CLASSIFICATION
DATE: PAGE NO. 1 OF 1
QA REPORT
Model P/N : 710-20202 NCR Control No : NCR-SCRAP2024-0032
Line : SMT LINE 5 Date Issued: JUNE 18,2024
Work Order : 85519776 Q'ty affected: 60 PCS
Wrong Value of Resistor R181 and R183 Not Detected at AOI Due to Wrong Program and the Parslist.
CONTAINMENT ACTION
100% Inspection
Unit(s) / Lot
Disposition : Rework ( If rework, attach flowchart & serial# monitoring )
Docs Needed: Rework Flow/Procedure Rework Logsheet/SN Re-Inspection Report
Man Machine
Rootcause Classification :
Method Material
Note: Can provide extra sheet if this page is not enough for the rootcause analysis. Others
Process/Systemic
TO BE FILLED UP BY CONCERNED DEPT.
Non-Detection
Re-Assigned to : N/A
CORRECTIVE/PREVENTIVE ACTIONS
CORRECTIVE ACTION RESPONSIBLE COMPLETION DATE
REMARKS
Manager
IMPORTANT: Need to provide related documentation as objective evidence of CA implementation and effectiveness
REMARKS:
NCR Rule:
Re quire me nt Ow ne r NCR Approva l
Le ve l SOD Tra ining
NCR 8D Sorting/Re w ork Ma na ge r
Re cord
Quality Issue Notice SOD <=30 No Yes No Sampling Information
Major 150 < SOD < 250 Yes Yes No 100% Sorting/Rework Approval
Quality Alert SOD = or > 250 No Yes Yes 100% Sorting/Rework Approval