1. Reason for the Job
(Ref. MMEL 21-26-10A)
AVIONICS EQUIPMENT VENTILATION COMPUTER (AEVC)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
REFERENCE QTY DESIGNATION
No specific AR ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific AR WARNING NOTICE(S)
C. Referenced Information
REFERENCE DESIGNATION
24-41-00-861-002-A Energize the Aircraft Electrical Circuits from the External Power
24-41-00-861-002-A-01 Energize the Aircraft Electrical Circuits from the APU
24-41-00-861-002-A-02 Energize the Aircraft Electrical Circuits from Engine 1(2)
24-41-00-862-002-A De-energize the Aircraft Electrical Circuits Supplied from the External
Power
24-41-00-862-002-A-01 De-energize the Aircraft Electrical Circuits Supplied from the APU
24-41-00-862-002-A-02 De-energize the Aircraft Electrical Circuits Supplied from the Engine
1(2)
31-60-00-860-001-A EIS Start Procedure
31-60-00-860-002-A EIS Stop Procedure
52-41-00-010-002-A Open the Avionics Compartment Doors for Access
52-41-00-410-002-A Close the Avionics Compartment Doors after Access
(Ref. Fig 21-26-00-991-00500-B - Skin Air-Inlet Valve)
(Ref. Fig 21-26-00-991-00900-B - Air-Conditioned Inlet Valve)
3. Job Set-up
SUBTASK 21-26-00-861-073-A
Selected 175 Airbus PROPRIETARY - Copyright © - Unpublished Work - See title page for details Page 1 of 5
A318/A319/A320/A321 – AMM LTM D1-LTM-
A320
Airbus Printed by Toolbox: 27 Jun 2024 22:24:54 CLT
UNCONTROLLED COPY 27 Jun 2024
Rev 45 - 01 May 2024
TASK 21-26-00-040-005-A Avionics Equipment Ventilation Computer (AEVC) Inoperative - Check of the Ventilation System Issue Date: 01 Aug 2023
EFFECTIVITY: On A/C ALL
SUBTASK 21-26-00-010-061-A
B. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at the access door 824.
(2) Open the access door 824 (Ref. TASK 52-41-00-010-002-A).
4. Procedure
SUBTASK 21-26-00-040-050-B
A. AEVC Check of the Ventilation System and the Skin Air-Inlet Valve-Closure
(Ref. Fig 21-26-00-991-00500-B - Skin Air-Inlet Valve)
(Ref. Fig 21-26-00-991-00900-B - Air-Conditioned Inlet Valve)
NOTE: On the ECAM, on the SD page, you can ignore the VENT BLOWER and VENT EXTRACT
messages that can come into view as INOP SYS when you set the BLOWER and
EXTRACT pushbutton switches to OVRD.
(1) Do this test:
ACTION RESULT
1.On the overhead panel, on the VENTILATION On the overhead panel, on the VENTILATION
section of overhead control and indicating panel section of overhead control and indicating panel
22VU: 22VU:
• Release the BLOWER and EXTRACT • The OVRD legends of the BLOWER and
pushbutton switches. EXTRACT pushbutton switches come on.
2.If the ground horn is activated, on rear circuit- The ground horn is deactivated.
breaker panel 121VU:
• Open circuit breaker 2WC .
• Close circuit breaker 2WC after the first
engine starts.
• Deactivate the ground horn after the
landing of the aircraft when the engines
stop.
3.Before you go away from the aircraft, on the
overhead panel, on ADIRS panel 41VU, pull the
selector switches and set them to OFF.
On the lower ECAM display unit, on the CAB
PRESS page:
• The outlet valve is not fully closed.
NOTE: The OVRD legends of the BLOWER
and EXTRACT pushbutton switches
come on if:
• The ventilation system is defective.
• You released the BLOWER and
EXTRACT pushbutton switches.
There are no color backgrounds on
the EFIS display.
In the aft avionics compartment:
• The air-conditioned inlet valve (21HQ) is
open.
• You can hear the sound of the extract fan in
operation.
Selected 175 Airbus PROPRIETARY - Copyright © - Unpublished Work - See title page for details Page 2 of 5
A318/A319/A320/A321 – AMM LTM D1-LTM-
A320
Airbus Printed by Toolbox: 27 Jun 2024 22:24:54 CLT
UNCONTROLLED COPY 27 Jun 2024
Rev 45 - 01 May 2024
TASK 21-26-00-040-005-A Avionics Equipment Ventilation Computer (AEVC) Inoperative - Check of the Ventilation System Issue Date: 01 Aug 2023
EFFECTIVITY: On A/C ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close the access door 824 (Ref. TASK 52-41-00-410-002-A).
(3) Remove the access platform(s).
SUBTASK 21-26-00-942-078-A
B. Safety Precautions
(1) Put a WARNING NOTICE(S) in the cockpit to tell the crew that the AEVC is deactivated.
(2) Make an entry in the logbook.
SUBTASK 21-26-00-862-079-A
Selected 175 Airbus PROPRIETARY - Copyright © - Unpublished Work - See title page for details Page 3 of 5
A318/A319/A320/A321 – AMM LTM D1-LTM-
A320
Airbus Printed by Toolbox: 27 Jun 2024 22:24:54 CLT
UNCONTROLLED COPY 27 Jun 2024
Rev 45 - 01 May 2024
TASK 21-26-00-040-005-A Avionics Equipment Ventilation Computer (AEVC) Inoperative - Check of the Ventilation System Issue Date: 01 Aug 2023
EFFECTIVITY: On A/C ALL
824
Z127 C
A
C FR24A
FR20
21HQ
B
MANUAL OVERRIDE
CONNECTOR
N_MM_212600_4_AEN0_01_00
Selected 175 Airbus PROPRIETARY - Copyright © - Unpublished Work - See title page for details Page 4 of 5
A318/A319/A320/A321 – AMM LTM D1-LTM-
A320
Airbus Printed by Toolbox: 27 Jun 2024 22:24:54 CLT
UNCONTROLLED COPY 27 Jun 2024
Rev 45 - 01 May 2024
TASK 21-26-00-040-005-A Avionics Equipment Ventilation Computer (AEVC) Inoperative - Check of the Ventilation System Issue Date: 01 Aug 2023
EFFECTIVITY: On A/C ALL
824
80VU
A
A
FR24A
FR20
15HQ
DEACTIVATION B
SWITCH
HANDLE
C
HANDLE LATCH
N_MM_212600_4_AAP0_01_00
Selected 175 Airbus PROPRIETARY - Copyright © - Unpublished Work - See title page for details Page 5 of 5