What is the correct SFP port that needs to be replaced on a


CLARiiON CX3 Series?
Audience Level: Partners

Article Content

Symptoms

What is the correct SFP port that needs to be replaced on a CLARiiON CX3 Series?
Which SFP port identified in log messages needs to be replaced?

B 06/03/12 09:57:04 scsitarg 71178016 SFP Diagnostic condition "Transmit power low alarm" detected
for physical port 3. Replace the SFP or SFP cable assembly.
A 06/03/12 09:58:02 2580 Storage Array Faulted FE SFP faulted on SP port 3 - SP B
A 06/03/12 09:59:32 7434 The Small Form Pluggable (SFP) in port (7) on SP (SP B) is faulted.
Servers may have lost a path to the storage system.

Resolution

The Faulted SFP that needs to be replaced is on storage processor (SP) port 3 - SP B.

Additional Information

The port (7) is the number from the array perspective and the Port (3) is the number from SP perspective .
Receiving a "Diagnostic condition 'Received power low alarm' detected for physical port #" message alone is not cause for replacing
the SFP. Look at other issues such as the host dropping the array connection or issues caused outside of the array, which
might cause this message to be reported.

SFP Part Numbers: Description FRU CRU

019-078-032 (SFP) Used in the two-port 1-Gb/s copper plus two-port 1-Gb Optical module (see note) Y Y

Used in the two-port 10-Gb/s FCoE I/O module

019-078-041 (SFP+) Used in the two-port 10-Gb/s optical I/O module (latch label 10 GbE iSCSI or v2) Y Y

Used in the two-port 10-Gb/s optical I/O module (latch label 10-GbE v3)

019-078-042 (SFP+) Used in the four-port 8-Gb/s Fibre Channel (FC) I/O module Y Y

Note: Only the two optical ports (physically labeled on this I/P module as 2 and 3, but logically fge-x-2 and fge-x-3) use this type of SFP

For CX4 adn VNX Series arrays with these events, see article emc325648

https://www.dell.com/support/kbdoc/en-sg/article/lkbprint?ArticleNumber=000103437&AccessLevel=40&Lang=en 1/2
2023/5/26 21:49 What is the correct SFP port that needs to be replaced on a CLARiiON CX3 Series? | Dell Singapore

Article Properties

Product
CLARiiON

Last Published Date


20 Nov 2020

Version
2

Article Type
Solution

https://www.dell.com/support/kbdoc/en-sg/article/lkbprint?ArticleNumber=000103437&AccessLevel=40&Lang=en 2/2

You might also like