1037PI Student Guide v1 0 PDF
1037PI Student Guide v1 0 PDF
This course provides a technical introduction to Hitachi Virtual Storage Platform (VSP) E
series, models, E990, E790 and E590. It explores the differences in the hardware
configurations and specifications of these VSP models. Also, you will review maintenance
and configuration change of new and different parts.
During this course you will complete numerous hands-on lab activities designed to build the
skills necessary to discover the key storage products presented in the course
Note: VSP midrange family include different models of VSP G series, F series, N series and E series.
These are described next.
Management Port
LAN Board (LANB)
Maintenance Port
SSD for backup of Memory
Cache Flash Memory
content in case of power
(CFM)
outage
LANB
CTL2
CTL1
CTL2
CTL1
Looks the same as HM850, but different DKB (s. chapter Back-End)
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank
A. 8
CHB
CFM
CTL2
CTL1
LANB
PSU + Battery
Back Plane
2 x I-Path
CPU
MEM MEM MEM MEM MEM MEM MEM MEM
MEM CPU MEM MEM CPU MEM MEM CPU MEM MEM CPU MEM
MEM MEM MEM MEM MEM MEM MEM MEM
FE FE FE FE FE FE
Note: VSP midrange family is a controller-based device. Each controller box has two
controllers (CTL1, CTL2) with dedicated microprocessors, memory DIMMs and ports.
© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Specifications I
Max.
Weight Depth CPUs/ Cores/ Cores/ DIMMs/ DIMM RAM/
VSP Model Types
(kg) (mm) CTL CPU System CTL (GB) System
(GB)
G900/F900 29.8 808.1 2 10 40 4/8 32/64 1024
G700/F700 29.8 808.1 2 6 24 4/8 16/32 512
G370/F370 16.1 813 1 10 20 2 32/64 256
G350/F350 16.1 813 1 6 12 2 16/32 128
E990 29.8 808.1 2 14 56 4/8 32/64 1024
E790 11.9 852 2 16 64 12 32 768
E590 11.9 852 2 6 24 6 / 12 32 768
Note: ¹Diskless *with CHBB attached ° BM5E / BM6E / BM7E with encryption
© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Box (CBX) With Front-End and
NVMe Back-End
Front-End Controller
NVMe 8Gb/s
Back-End Drives
2U DBN
24 x SFF
Fibre Channel SSD SFF
32Gb/s
Backplane PCIe Gen3
4 Ports
iSCSI (SFP) 4U Model
10Gb/s
2 Ports
iSCSI (10Base-T)
1/10Gb/s
2 Ports
2U Models
NVMe DKBN has two ports with 8Gb/s port speed each
1st Feature
2nd Feature
CTL1
VSP G350,
F350, G370
and F370
1 Port / CTL
CTL1 CTL2
Note: VSP G350, F350, G370 and F370 have one external port per CTL, embedded on
CTL board. VSP E590 and E790 models have no external back-end ports
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank
A. 2
B. 4
A VSP F700 system with attached drive
boxes (DBs) has _________ DKBs. C. 6
D. 8
A. HM800
B. HM850
The SVP is mandatory for _________
midrange storages. C. HM900
Controller Box 4U
• VSP G700, F700,
G900, F900,
VSP E990
• 1 LANB per CTL
• 2 ports per LANB
BE Port
LAN Reset
UPS
*1 To upgrade memory, both controllers are blocked one by one to remove the board and insert the DIMMs. During the upgrade process, the entire system runs with
degraded performance. Therefore, Cache upgrades and Shared memory expansion tasks should run in quite time.
© Hitachi Vantara LLC 2021. All Rights Reserved.
DIMM Installation (4U)
DIMM13
DIMM12
DIMM02
DIMM03 Rear
Front
DIMM11
DIMM10
DIMM00
DIMM01
CMG0
CMG1
DIMM01
DIMM00
Front Rear
CMG0
CMG0
CMG1
Because of the memory being striped among all DIMMs in the same CTL, a damaged DIMM
will block the entire CTL-board and all dedicated ports
All DIMMs must be the same type
DIMM type change is supported for upgrading memory on fully populated boards
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank
A. 1
B. 2
A Cache Memory Group in a VSP E590 has
___ DIMMs per CTL C. 4
D. 6
Base 4.4 PB
Extension1 8.05 PB
256
Extension2 12.5 PB
Extension3 16.6 PB
CFM-20
CFM-21
Controller Box 4U
• VSP G700, F700,
G900, F900, E990
• 1 or 2 CFM per CTL
• Front
CFM-10
CFM-11
Number of CFM:
VSP G350, F350, G370, F370, E590, E790 : CFM-1 + CFM-2
VSP G700, F700, G900, F900, E990: CFM-10/20 + CFM 11/21
© Hitachi Vantara LLC 2021. All Rights Reserved.
CFM Locations (2U CTL)
VSP G900/ VSP G700 VSP G370/ VSP G350/ VSP E590
Memory / VSP E990
F900 F700 F370 F350 E790
System
CFM CFM CFM CFM CFM CFM
CFM 1/2 CFM 1/2 CFM 1/2
10/20 11/21 10/20 11/21 10/20 11/21
64GB BM15 BM15
128GB BM35 ----- BM15 BM15
256GB BM35 ----- BM35 ----- BM15 BM55 -----
384GB° ----- ----- ----- ----- ----- ----- BM70
BM35 BM35 BM55 BM55
512GB BM35 BM35
BM45 ----- BM65 -----
768GB BM70 BM70
Supported types are BM15, BM35, BM45, BM55, BM65 and BM70
A. 1 CPU/CTL
B. 2 CPUs/CTL
A VSP E790 has _________ CPUs/CTL.
C. 3 CPUs/CTL
D. 4 CPUs/CTL
Controller Box 4U
BAT-B21 BAT-B22 BAT-B23
• VSP G700, F700,
G900, F900, E990
• Located on front side
• 1 battery per fan
chassis (BKMF)
• 3 batteries per CTL
BAT-B11 BAT-B12 BAT-B13
Number of BKMF:
• CTL1: BKMF10, BKMF11, BKMF12, BKMF13
• CTL2: BKMF20, BKMF21, BKMF22, BKMF23
• BKMF10 and BKMF20 are not supported for mounting batteries (just fans)
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fan Chassis With Battery (4U Controller)
BAT-B11
BKMF-11
© Hitachi Vantara LLC 2021. All Rights Reserved.
Battery Locations (2U CTL SAS)
PSU
Battery
Power Supply
Note: DB60 and DBN are specified for temperature up to 35°C only.
Controller Box 4U
• VSP G700, F700,
G900, F900, E990
• 1 PS per CTL
PSU1 PSU2
PSU2
Controller Box 2U
SAS
• VSP G350, F350,
PSU1 G370, F370
• 1 PS per CTL
Controller Box 2U
NVMe
• VSP E590, E790
• 1 PS per CTL
PSU1 PSU2
Front End ports are available for Fibre Channel and iSCSI
CTL1
VSP E590 and VSP E790 do not support attached drive boxes
PS
A. 24
C. 48
D. 12
DBS / DBL 7 11 36 48
DB60 4 6 20 24
DBF 36 48
DBN 4
Drive max. 264 384 1200 1440 24 24 96
DKB / CTL Embedded Port 2 2/4 Internal Port 2/4
Parts Size
CTL 4U DB-03 DB(DBN)
CBL
4U
2E 2F
1 or 2 DBs/ System
1E 1F
4 DKBNs / CTL 8 ports / CTL
8 DKBNs / System 16 ports / System
Pattern 2
2E 2F
3 or 4 DBs/ System
DKBN(BE)
1E 1F Pattern 3: diskless configuration.
© Hitachi Vantara LLC 2021. All Rights Reserved.
Back-End VSP E990
RAID Group (RG) Array group Error Checking and Correction (ECC) group
Supported Drive Types give the customer flexibility to put the focus on
either performance or maximum capacity
Storage
Navigator/Web Maintenance IP
HSAE pull-down Ops Center
console/BEM Address on Web MPC
menu Administrator
with manual browser
drive selection
Step#2: Identifying the failed parts Step#2: Identifying the failed parts
Step#4: Replace the drive Step#4: Block the CTL from GUI
ON ON
OFF
OFF Step#6: Recover CTL from GUI
Automator
Protector
Management
Client Data Center
Management Server
Hitachi Ops Center Hitachi Ops Center Hitachi Ops Center
Automator Protector Analyzer Deploy by
Ops Center
Hitachi Ops Center API Hitachi Ops Center Hitachi Ops Center
OVA
Configuration Manager Analyzer Detail View Common Services
Basic LDEVs are created only, while Parity Groups are built for creating and expanding pools
Basic LDEVs for other purposes (CMD, Provisioning) require different tools
(Ops Center, Command Suite, Storage Navigator, RAIDCOM, REST API).
Basic LDEVs are addressed top-down (for example, CU:ID will be FE:FF, FE:FE, FF:FD
and so on)
With MPC, which is a CE tool, there is still a Storage Navigator (Webconsole) for SVP-less
storages
All actual Hitachi midrange series have HSAE embedded on the CTL
boards
https://learningcenter.hds.com/private/i1t/Ops_Center
_Learning_Path_links_Bnr2_Oct2020.pdf
Chat
Q&A
Feedback Options
− Raise Hand
− Yes/No
− Emoticons
Markup Tools
− Drawing Tools
− Text Tool
© Hitachi Vantara LLC 2021. All Rights Reserved.