© Hitachi Vantara LLC 2021. All Rights Reserved.


Course Description

This course provides a technical introduction to Hitachi Virtual Storage Platform (VSP) E
series, models, E990, E790 and E590. It explores the differences in the hardware
configurations and specifications of these VSP models. Also, you will review maintenance
and configuration change of new and different parts.

During this course you will complete numerous hands-on lab activities designed to build the
skills necessary to discover the key storage products presented in the course

© Hitachi Vantara LLC 2021. All Rights Reserved.


Prerequisites

 Successfully passed the exam HQT-4180 or HQT-4150 (within last 3 years)

 Helpful Prerequisite Knowledge


• Basic knowledge of RAID, SAN, LAN and Server technologies

© Hitachi Vantara LLC 2021. All Rights Reserved.


Course Objectives

 When you complete this course, you should be able to:


• Describe the architecture of midrange systems of Hitachi Virtual Storage
Platform (VSP) E series
• Discuss the specifications of the VSP E series midrange family
• Identify the internal components and their function
• Describe the back-end design and layout for each model, including drive
trays and disk types
• Compare the maintenance and management GUI of different VSP E models

© Hitachi Vantara LLC 2021. All Rights Reserved.


Course Topics
Modules Lab Activities
1. Overview 1. Component Identification
2. System Architecture 2. Back-End Architecture
3. Back-End 3. Maintenance
4. Maintenance 4. Change Configuration (optional)
5. Management GUI 5. Management GUI

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi VSP E Series
Refresher Workshop for
Certified Partners:
What’s New
Overview

© Hitachi Vantara LLC 2021. All Rights Reserved.


Module Objectives

 When you complete this module, you should be able to:


• Identify where the Hitachi Virtual Storage Platform (VSP) E series midrange
family fit in the Hitachi Vantara storage portfolio
• Discuss the specifications for the VSP midrange systems

Note: VSP midrange family include different models of VSP G series, F series, N series and E series.
These are described next.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Overview

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Storages Overview
Product Name Family Back-End Firmware
R900 VSP 5500 / VSP 5100 Enterprise SAS/NVMe 90-

R800 / R850 VSP G1000 / VSP G1500/F1500 Enterprise SAS 80-

R700 VSP Enterprise SAS 70-

HM900 VSP E790 / VSP E590 / VSP E990 Midrange NVMe 93


VSP x350 / VSP x370
HM850 Midrange SAS 88-
VSP x700 / VSP x900
VSP G200
HM800 Midrange SAS 83-
VSP x400 / VSP x600 / VSP x800
Enterprise entry
HM700 HUS VM
level
SAS 73-

DF850 HUS 110 / HUS 130 / HUS 150 Modular SAS

© Hitachi Vantara LLC 2021. All Rights Reserved.


Specifications

© Hitachi Vantara LLC 2021. All Rights Reserved.


Midrange Block Storage With SAS Back-End
(HM850)
 VSP F350, F370 (2U CBX)
• SSD
• 1 CPU, 2 DIMMs per CTL
• 6 or 10 cores per CPU

 VSP G350, G370 (2U CBX)


• SSD, SAS 10k, NL-SAS
• 1 CPU, 2 DIMMs per CTL
• 6 or 10 cores per CPU

 VSP F700, F900 (4U CBX)


• SSD, FMD
• 2 CPUs, 4 or 8 DIMMs per CTL
• 6 or 10 cores per CPU

 VSP G700, G900 (4U CBX)


• FMD, SSD, SAS 10k, NL-SAS
• 2 CPUs, 4 or 8 DIMMs per CTL
• 6 or 10 cores per CPU

© Hitachi Vantara LLC 2021. All Rights Reserved.


Midrange Block Storage With NVMe Back-End
(HM900)

 VSP E590, E790 (2U CBX)


• SSD
• 2 CPUs, 6 or 12 DIMMs per CTL
• 6 or 16 cores per CPU
• No external Drive Boxes

 VSP E900 (4U CBX)


• SSD
• 2 CPUs, 4 or 8 DIMMs per CTL
• 14 cores per CPU
• Max. 4 external Drive Boxes

© Hitachi Vantara LLC 2021. All Rights Reserved.


Midrange Unified Storage With SAS Back-End

• VSP N400, N600, N800 (4U CBX)

• FMD, SSD, SAS 15k, SAS 10k, NL-SAS


• 2 CPUs / CTL
• VSP N400 VSP N600 4 cores per CPU
• VSP N800 8 cores per CPU
• VSP N400 4 DIMMs per CTL
• VSP N600, VSP N800 4 or 8 DIMMs per CTL
• HFB as embedded NAS
• Based on HM800

© Hitachi Vantara LLC 2021. All Rights Reserved.


Quick Question

What is the major difference between the models


of VSP E series and VSP F/G series?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Brainstorming

What role has Hitachi Storage Virtualization


Operating System (SVOS) for the midrange
and enterprise storages?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Your Takeaways

What are 1-2 takeaways from this module?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Key Takeaways

Controllers have different Chassis sizes (2U and 4U)

Unified Storage is offered for combining Block- and NAS-storage in one


Chassis to simplify management and cabling

All-flash arrays for maximum throughput and minimum response time

New NVMe Back End for best performance in class

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi VSP E Series
Refresher Workshop for
Certified Partners:
What’s New
System Architecture

© Hitachi Vantara LLC 2021. All Rights Reserved.


Module Objectives

 Upon completion of this module, you should be able to:


• Describe the new Microprocessors or CPUs
• Describe different CBX structures for arrays with 2U CBX
• Describe different DIMM structure on 2U controllers
• Describe different Back Modules (BM)

Note: Another term for DKC is CBX (Controller Box)


© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Box 4U VSP E990

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Box (4U) Overview
Part Explanation
2 CPUs Cascade Lake,
Controller Board (CTL)
4 or 8 DIMMs
Channel Board (CHB) Fibre Channel, iSCSI, PCIe°
0* / 2 / 4 DKBs / CTL
Disk Board (DKB)
DKB has 2 Ports NVMe 8Gb/s

PS Unit (PSU) One PSU per CTL

Management Port
LAN Board (LANB)
Maintenance Port
SSD for backup of Memory
Cache Flash Memory
content in case of power
(CFM)
outage
LANB

Backup Module with FAN Battery for backup in case of a


(BKMF) power outage and fan

°For attaching CHBB


* Diskless configuration
© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Box (4U Front View)

CTL2

CTL1

LEDs BKMF LAN Reset + Block LED CFM

Looks the same as HM850

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Box (4U) Rear View
LANB

CTL2

CTL1

CHB DKB PSU

Looks the same as HM850, but different DKB (s. chapter Back-End)
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank

A. 8

A total of ____ CHBs can be mounted on a B. 12


VSP E990 system with 4 DKBs installed.
C. 16

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Box 2U
VSP E590 and VSP E790

© Hitachi Vantara LLC 2021. All Rights Reserved.


Differences 2U CBX HM850 Versus HM900
Part HM850 HM900
CTL2
CTL Board Position (Rear view) CTL1 CTL2
CTL1

2 x (6- or 10-) core Intel 2 x (6- or 16-) core Intel


CPU / CTL
Broadwell E5-2618Lv4 Xeon Cascade Lake-SP Xeon
DIMMs / CTL 2 6 or 12
Channel Board (CHB) 2 CHB slots per CTL 3 CHB slots per CTL
External BE Port 1 -----
Backend Interface SAS 12 Gb/s NVMe 8Gb/s
BM70
Backup Module Types BM15
BM7E (encryption)

Backup Module Location Center of Rear Side Embedded in PSU

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Box NVMe (2U) Overview
Part Explanation
2 CPUs Cascade Lake,
Controller Board (CTL)
6 or 12 DIMMs, LANB, Fans LANB Rear
Channel Board (CHB) Fibre channel, iSCSI
CTL2 CHB
BE Port Internal CPU
PS Unit (PSU) One PSU per CTL Fans CPU
LAN Board Management Port
(LANB embedded) Maintenance Port DB0
PSU
Cache Flash Memory SSD for backup of Memory
content in case of power Front
(CFM) outage
Battery
Battery for backup in case of a
Backup Module (BKM)
power outage (PSU chassis)
DB0 Embedded DB (2,5”)

Fans Embedded on CTL board


© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Box (CBSN 2U Front View)

LEDs SFF SSD DB0

 CBSS – Controller Box Small SFF SAS (24x2,5“ slots)


 CBSL – Controller Box Small LFF SAS (12x3,5“ slots)
Looks the same as HM850  CBSN – Controller Box Small SFF NVME (24x2,5“ slots

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Box CBSN (2U Rear View)

CHB
CFM

CTL2

CTL1

LANB
PSU + Battery

© Hitachi Vantara LLC 2021. All Rights Reserved.


VSP E590 and VSP E790 Block Diagram
CBX Difference from HM850
Drive Drive Drive Drive Drive Drive Drive Drive Drive Drive Drive

Back Plane
2 x I-Path

CTL1 PCIe CTL2 PCIe 12 x DIMM Slots


Gen.3 x2 *24 Gen.3 x2 *24
PCIe Switch PCIe Switch
3 x CHB Slots
I-path I-path I-path I-path

CPU
MEM MEM MEM MEM MEM MEM MEM MEM
MEM CPU MEM MEM CPU MEM MEM CPU MEM MEM CPU MEM
MEM MEM MEM MEM MEM MEM MEM MEM

PCIe PCIe PCIe PCIe PCIe PCIe


Gen3 x16 Gen3 x8 Gen3 x16 Gen3 x16 Gen3 x8 Gen3 x16

FE FE FE FE FE FE

Slot A Slot B Slot C Slot A Slot B Slot C

© Hitachi Vantara LLC 2021. All Rights Reserved.


True or False

A VSP E590 system has 40 CPU cores.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Specification

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Midrange Models
VSP Model Parts Name CBX Height Remark
G900/F900 HM850XL CBLH2 4U 10 Core CPU
G700/F700 HM850L CBLH1 4U 6 Core CPU
G370/F370 HM850M CBSS/CBSL 2U 10 Core CPU, embedded BE-Port and LAN Ports
G350/F350 HM850S CBSS/CBSL 2U 6 Core CPU, embedded BE-Port and LAN Ports
E990 HM900 CBLHN 4U 14 Core CPU
E790 HM900 CBSN 2U 16 Core CPU, internal BE-Port and LAN Ports
E590 HM900 CBSN 2U 6 Core CPU, internal BE-Port and LAN Ports

Note: VSP midrange family is a controller-based device. Each controller box has two
controllers (CTL1, CTL2) with dedicated microprocessors, memory DIMMs and ports.
© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Specifications I
Max.
Weight Depth CPUs/ Cores/ Cores/ DIMMs/ DIMM RAM/
VSP Model Types
(kg) (mm) CTL CPU System CTL (GB) System
(GB)
G900/F900 29.8 808.1 2 10 40 4/8 32/64 1024
G700/F700 29.8 808.1 2 6 24 4/8 16/32 512
G370/F370 16.1 813 1 10 20 2 32/64 256
G350/F350 16.1 813 1 6 12 2 16/32 128
E990 29.8 808.1 2 14 56 4/8 32/64 1024
E790 11.9 852 2 16 64 12 32 768
E590 11.9 852 2 6 24 6 / 12 32 768

© Hitachi Vantara LLC 2021. All Rights Reserved.


Controller Specifications II
DKBs/ DBs Drives CHBs / CFMs/ CFMs Batteries
VSP Model
CTL Max. Max. CTL CTL Type /CTL

G900/F900 0¹/2/4 2x24 1440 1-6 / 8¹* 1/2 BM35/BM45 3


G700/F700 0¹/2 36 1200 1-6 / 8¹ 1/2 BM35 3
G370/F370 Emb. Port 1 int.+ 11 384 1-2 1 BM15 1

G350/F350 Emb. Port 1 int.+ 7 264 1-2 1 BM15 1

E990 0¹/2/4 4 96 1-6 / 8¹* 1/2 BM55°/BM65° 3

E790 Internal Internal 24 1-3 1 BM70° 1

E590 Internal Internal 24 1-3 1 BM70° 1

Note: ¹Diskless *with CHBB attached ° BM5E / BM6E / BM7E with encryption
© Hitachi Vantara LLC 2021. All Rights Reserved.
Controller Box (CBX) With Front-End and
NVMe Back-End
Front-End Controller

NVMe 8Gb/s
Back-End Drives
2U DBN
24 x SFF
Fibre Channel SSD SFF
32Gb/s
Backplane PCIe Gen3

4 Ports
iSCSI (SFP) 4U Model

10Gb/s
2 Ports
iSCSI (10Base-T)
1/10Gb/s
2 Ports

2U Models

© Hitachi Vantara LLC 2021. All Rights Reserved.


Disk Board (DKB)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Disk Board (DKB) Basics
DKB – Disk Board (technical term) BED – Back-End Director (marketing term)

 VSP E series supports DKBN and EDKBN (encryption) only

 NVMe DKBN has two ports with 8Gb/s port speed each

 For encrypting RAID Groups (RG),


• An EDKBN supporting encryption is necessary
• RGs must be formatted with encryption enabled

© Hitachi Vantara LLC 2021. All Rights Reserved.


DKBN Port Numbers VSP E990

1st Feature

2nd Feature

© Hitachi Vantara LLC 2021. All Rights Reserved.


DKBN LEDs

LED Color Status Function


Green On Power On
Status Red On DKB can be removed
---- Off Power Off
Blue On Link Status
Port
--- Off Link down / not ready
Status Port

© Hitachi Vantara LLC 2021. All Rights Reserved.


DKBN Locations: Controller Box 4U

VSP E990 CTL2


2/4 DKBs (4/8 Ports) / CTL

CTL1

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End Port Locations: Controller Box 2U

VSP G350,
F350, G370
and F370
1 Port / CTL

CTL1 CTL2

Note: VSP G350, F350, G370 and F370 have one external port per CTL, embedded on
CTL board. VSP E590 and E790 models have no external back-end ports
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank

A. 2

B. 4
A VSP F700 system with attached drive
boxes (DBs) has _________ DKBs. C. 6

D. 8

© Hitachi Vantara LLC 2021. All Rights Reserved.


Service Processor (SVP)

© Hitachi Vantara LLC 2021. All Rights Reserved.


SVP Basics

 1U server manufactured by Supermicro


 Runs Microsoft Windows 10 Embedded
operating system
 Mandatory interface for Hitachi Command
Suite (HCS) and Hitachi Storage Navigator
(SN)
• No SVP for VSP E590 and E790
 Preinstalled before shipment

© Hitachi Vantara LLC 2021. All Rights Reserved.


SVP Support

SVP is not Storage Use Hitachi


HCS does
supported for Navigator is Ops Center
not support
VSP E590 not available Administrator
2U NVMe
and VSP for 2U NVMe or HSAE to
storages
E790 storages administrate

© Hitachi Vantara LLC 2021. All Rights Reserved.


Fill in the Blank

A. HM800

B. HM850
The SVP is mandatory for _________
midrange storages. C. HM900

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board (LANB)

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board (LANB) Basics

Two interfaces For 4U Controller For 2U Controller

• Maintenance port • A dedicated board • Embedded on


(for MPC) • Maintained Controller Board
• Management port individually • VSP models,
(customer LAN) • Same for HM850 G350, F350, G370,
and HM900 F370, E590 and
E790

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board Locations (4U CTL)

Controller Box 4U
• VSP G700, F700,
G900, F900,
VSP E990
• 1 LANB per CTL
• 2 ports per LANB

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board Locations (Controller Box 2U)

Controller Box 2U SAS


• VSP G350, F350,
G370, F370
• 2 embedded LAN
ports per CTL

Controller Box 2U NVMe


• VSP E590, E790
• 2 embedded LAN
ports per CTL

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board Embedded (Controller Box 2U SAS)

BE Port

LAN Reset
UPS

UPS I/F for Uninterruptable Power Supply

I/F Maintenance LAN

I/F Management LAN

LAN-RST Switch for reset of LAN-Unit (ask support first!)

© Hitachi Vantara LLC 2021. All Rights Reserved.


LAN Board Embedded (Controller Box 2U NVMe)

UPS I/F for Uninterruptable Power Supply (Japan only)

I/F Maintenance LAN

I/F Management LAN

CTL ALM Alarm LED

LAN-RST Switch for reset of LAN-Unit (ask support first!)

BACKUP Status of Backup (s. next slide)


STS
© Hitachi Vantara LLC 2021. All Rights Reserved.
LAN Board Embedded (Controller Box 2U NVMe)

This example from the Maintenance


Manual e06Loc0.pdf explains LEDs
and switches for the LAN Board of a CBSN
(CBX for VSP E590 and E790)

© Hitachi Vantara LLC 2021. All Rights Reserved.


True or False

The LAN Reset button for a VSP E590 is located at


the CTL front.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Memory

© Hitachi Vantara LLC 2021. All Rights Reserved.


Memory Basics (Refresh)

Located on DIMMs on the controller boards

Increased and decreased nondisruptively*¹

Maximum size: 1024GB (VSP models: F900, G900 and E990 )

Distributes different areas of memory


LM Local Memory
PM Package Memory
DxBF Data Transfer Buffer
Installed in units of CMG (Cache Memory Group)
SM Shared Memory
CM Cache Memory
Write data is always duplicated

*1 To upgrade memory, both controllers are blocked one by one to remove the board and insert the DIMMs. During the upgrade process, the entire system runs with
degraded performance. Therefore, Cache upgrades and Shared memory expansion tasks should run in quite time.
© Hitachi Vantara LLC 2021. All Rights Reserved.
DIMM Installation (4U)

DIMM13
DIMM12

DIMM02
DIMM03 Rear
Front
DIMM11
DIMM10

DIMM00
DIMM01

CMG0
CMG1

© Hitachi Vantara LLC 2021. All Rights Reserved.


DIMM Installation VSP Models: G350, F350,
G370 and F370

DIMM01
DIMM00
Front Rear

CMG0

© Hitachi Vantara LLC 2021. All Rights Reserved.


DIMM Installation VSP E590 and VSP E790
DIMM02
DIMM01
DIMM00
DIMM10
DIMM11
DIMM12
Front Rear
DIMM05
DIMM04
DIMM03
DIMM13
DIMM14
DIMM15

CMG0
CMG1

© Hitachi Vantara LLC 2021. All Rights Reserved.


Memory Specification
DIMM

Pos. VSP Model Configurable unit / Max capacity /


Capacity type Installable DIMM number
CTL CTL

1 G900, F900 32GB, 64GB 8 slot/CTL (CMG0, CMG1) 4 DIMM 512GB

2 G700, F700 16GB, 32GB 8 slot/CTL (CMG0, CMG1) 4 DIMM 256GB


3 G370, F370 32GB, 64GB 2 slot/CTL (CMG0) 2 DIMM 128GB
4 G350, F350 16GB, 32GB 2 slot/CTL (CMG0) 2 DIMM 64GB

5 E990 32GB, 64GB 8 slot/CTL (CMG0, CMG1) 4 DIMM 512GB

6 E790 32GB 12 slot/CTL (CMG0, CMG1) 6 DIMM 384GB

7 E590 32GB 12 slot/CTL (CMG0, CMG1) 6 DIMM 384GB

 Because of the memory being striped among all DIMMs in the same CTL, a damaged DIMM
will block the entire CTL-board and all dedicated ports
 All DIMMs must be the same type
 DIMM type change is supported for upgrading memory on fully populated boards
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fill in the Blank

A. 1

B. 2
A Cache Memory Group in a VSP E590 has
___ DIMMs per CTL C. 4

D. 6

© Hitachi Vantara LLC 2021. All Rights Reserved.


Shared Memory GUI Location

© Hitachi Vantara LLC 2021. All Rights Reserved.


Shared Memory Configuration (HM900)
RAM/ Extension Range System DP Pool Capacity
System VSP VSP VSP VSP VSP VSP
Min. (GB) E590 E790 E990 E590 E790 E990
384 Base 4.4 PB

384 Extension1 8.05 PB

768 Base 4.4 PB

768 Extension1 8.05 PB

768 Extension2 12.5 PB

Base 4.4 PB

Extension1 8.05 PB
256
Extension2 12.5 PB

Extension3 16.6 PB

Note: Additional extensions support additional pool capacity.


© Hitachi Vantara LLC 2021. All Rights Reserved.
Shared Memory Size (GB)

SM Function VSP VSP VSP VSP VSP VSP VSP


G350, G370, G700, G900, E590 E790 E990
F350 F370 F700 F900
Base 34 72.0 74.5 108.5 149.5 149.5 155.5
Extension1 42.5 94.0 96.5 124.5 175.5 175.5 171.5
Extension2 54.5 110.0 112.5 140.5 181.5 187.5
Extension3 128.5 156.5 203.5

© Hitachi Vantara LLC 2021. All Rights Reserved.


Cache Flash Memory (CFM)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Cache Flash Memory (CFM) Basics
Based on SSD mounted in controller chassis

Used to protect cache content

Can be replaced nondisruptively

Located on the front side of 4U controllers

Located on the rear side of 2U controllers

Number of CFM modules depends on memory size and CBX type

Type of CFM depends on controller type and memory size


• CFM is the term for the unit, BM(xy) is the type of SSD mounted in CFM

© Hitachi Vantara LLC 2021. All Rights Reserved.


CFM Locations (4U CTL)

CFM-20

CFM-21
Controller Box 4U
• VSP G700, F700,
G900, F900, E990
• 1 or 2 CFM per CTL
• Front

CFM-10

CFM-11
Number of CFM:
 VSP G350, F350, G370, F370, E590, E790 : CFM-1 + CFM-2
 VSP G700, F700, G900, F900, E990: CFM-10/20 + CFM 11/21
© Hitachi Vantara LLC 2021. All Rights Reserved.
CFM Locations (2U CTL)

Controller Box 2U SAS


• VSP G350, F350, G370,
F370
• 1 CFM per CTL
CFM 1 CFM 2
• Rear

Controller Box 2U NVMe


CFM 2
• VSP E590, E790
• 1 CFM per CTL
• Rear
CFM 1

© Hitachi Vantara LLC 2021. All Rights Reserved.


CFM Specification

VSP G900/ VSP G700 VSP G370/ VSP G350/ VSP E590
Memory / VSP E990
F900 F700 F370 F350 E790
System
CFM CFM CFM CFM CFM CFM
CFM 1/2 CFM 1/2 CFM 1/2
10/20 11/21 10/20 11/21 10/20 11/21
64GB BM15 BM15
128GB BM35 ----- BM15 BM15
256GB BM35 ----- BM35 ----- BM15 BM55 -----
384GB° ----- ----- ----- ----- ----- ----- BM70
BM35 BM35 BM55 BM55
512GB BM35 BM35
BM45 ----- BM65 -----
768GB BM70 BM70

1024GB BM45 BM45 BM65 BM65

Note: BM55, BM65, BM70 with encryption: BM5E, BM6E, BM7E


© Hitachi Vantara LLC 2021. All Rights Reserved.
Rule for CFM Installation

All CFMs in the system must be same type

Supported types are BM15, BM35, BM45, BM55, BM65 and BM70

BM45 or BM65 are required when 64GB DIMMs are installed in


XL model (VSP G900, F900 / E990)

BM55, BM65 and BM70 can be ordered as encrypted types (BM5E,


BM6E, BM7E)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Fill in the Blank

A. 1 CPU/CTL

B. 2 CPUs/CTL
A VSP E790 has _________ CPUs/CTL.
C. 3 CPUs/CTL

D. 4 CPUs/CTL

© Hitachi Vantara LLC 2020. All Rights Reserved.


Backup Module (BKM)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Backup Module (BKM) Basics

Supports CFM and


A set of single or multiple Located in fan chassis
memory with power in
NiMH 12-volt batteries (4U controller front) or at
case of main power
per CTL controller rear (2U)
issues
• Single unit per CTL for
VSP models: G350,
F350, G370, F370,
E590 and E790
• 3 battery units per CTL
for VSP models: G700,
F700, G900, F900 and
E990

© Hitachi Vantara LLC 2021. All Rights Reserved.


Battery Locations (4U CTL)

Controller Box 4U
BAT-B21 BAT-B22 BAT-B23
• VSP G700, F700,
G900, F900, E990
• Located on front side
• 1 battery per fan
chassis (BKMF)
• 3 batteries per CTL
BAT-B11 BAT-B12 BAT-B13

Number of BKMF:
• CTL1: BKMF10, BKMF11, BKMF12, BKMF13
• CTL2: BKMF20, BKMF21, BKMF22, BKMF23
• BKMF10 and BKMF20 are not supported for mounting batteries (just fans)
© Hitachi Vantara LLC 2021. All Rights Reserved.
Fan Chassis With Battery (4U Controller)

BAT-B11

BKMF – Backup Module Fan


BAT – Battery

BKMF-11
© Hitachi Vantara LLC 2021. All Rights Reserved.
Battery Locations (2U CTL SAS)

Controller Box 2U SAS


• VSP G350, F350,
G370, F370,
• Located on the rear
side
• One battery per CTL

© Hitachi Vantara LLC 2021. All Rights Reserved.


Battery Locations (2U CTL NVMe)

Controller Box 2U NVMe


• VSP E590, E790
• 1 Battery per CTL
• Rear in PSU chassis

PSU

Battery

Power Supply

© Hitachi Vantara LLC 2021. All Rights Reserved.


Battery Lifetime

Intake CBLH/ CBXSS/ CBXSL/


CBSN
Temperature CBLHN CBSS CBSL
Up to 24°C 5 years 5 years 5 years 5 years
Up to 30°C 5 years 5 years 4 years 5 years
Up to 34°C 4 years 4 years 3 years 4 years
Up to 35°C 3 years 3 years 2 years 3 years
Up to 40°C 3 years 3 years 2 years

Note: DB60 and DBN are specified for temperature up to 35°C only.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Power Supply (PS)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Power Supply (PS) Basics

VSP midrange family In case of a failed


controller has 2 power line or a failed
power supplies power supply (PS):
• Located at the rear side • Remaining PS supports
of the controller the entire system with
• Connected to 200-240 V power
AC power • Both controllers will stay
• Deliver 12 V DC power online

© Hitachi Vantara LLC 2021. All Rights Reserved.


Power Supply Locations (4U CTL Rear Side)

Controller Box 4U
• VSP G700, F700,
G900, F900, E990
• 1 PS per CTL

PSU1 PSU2

© Hitachi Vantara LLC 2021. All Rights Reserved.


Power Supply Locations (2U CTL Rear Side)

PSU2
Controller Box 2U
SAS
• VSP G350, F350,
PSU1 G370, F370
• 1 PS per CTL

Controller Box 2U
NVMe
• VSP E590, E790
• 1 PS per CTL

PSU1 PSU2

© Hitachi Vantara LLC 2021. All Rights Reserved.


Your Takeaways

What are 1-2 takeaways from this module?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Key Takeaways

Protecting cache in case of power outages by smart backup solution


based on battery and SSD
State of the art multicore processors on a full redundant dual controller
system

Two separate LAN interfaces for management and maintenance

Front End ports are available for Fibre Channel and iSCSI

SVP-less configuration for new models supported

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi VSP E Series
Refresher Workshop for
Certified Partners:
What’s New
Back-End

© Hitachi Vantara LLC 2021. All Rights Reserved.


Module Objectives

 When you complete this module, you should be able to:


• Explain the back-end of Hitachi Virtual Storage Platform (VSP) E series
• Explain the drive box of VSP E990
• Describe the back-end cabling of VSP E990
• Discuss drive offerings of VSP E series

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End Overview

Back-end is provided by disk board (DKB) transferring data between


drives and cache

DKBN has 2 ports NVMe 8Gb/s

For encrypting Parity Groups, a EDKB or EDKBN supporting encryption


(4U CBX) or another CTL board (2U CBX) is required

• FMD has onboard encryption


• Encryption requires always a license to be installed

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End Specifications

© Hitachi Vantara LLC 2021. All Rights Reserved.


Pools, Volumes, Drives and Parity Groups
Spare Phys.
LDEV PG Drives
VSP Model Drives Capacity
Max. Max. Max. Max Max.
G900, F900 64k 480 1440 64 17335TB

G700, F700 48k 400 1200 48 13001TB

G370, F370 32k 128 384 24 4333TB

G350, F350 16k 88 264 16 2889TB

E990 64k 24 96 8 1444TB

E790 48k 6 24 2 361TB

E590 32k 6 24 2 361TB

F – All-flash array G – Hybrid, supporting flash devices and disks


E – Arrays with NVMe Back-End (SSD only)
© Hitachi Vantara LLC 2021. All Rights Reserved.
DKB Locations Controller Box 4U

VSP E990 CTL2


2/4 DKBs (4/8 Ports) / CTL

CTL1

E990 has two or four DKBs per


CTL if there are DBs attached

Note: VSP E590 and E790 have no external Back-End ports


© Hitachi Vantara LLC 2021. All Rights Reserved.
Back-End – VSP E Models

VSP E990 VSP E590/E790

• Similar cabling • No external BE


structure as VSP ports
G900 and F900 • No external DBs
• Based on NVMe can be attached
• Two different CTL
board offerings for
non-encrypted and
encrypted
environment

© Hitachi Vantara LLC 2021. All Rights Reserved.


Drive Box (DB) Type

© Hitachi Vantara LLC 2021. All Rights Reserved.


Drive Box (DB) Basics
Drive Box NVMe (DBN)

VSP E590 and VSP E790 do not support attached drive boxes

VSP E990 supports up to 4 DBN

DBN is a 2U Drive Box

24 slots for 2.5” devices (SSD)

Two Power Supplies

Two Enclosure Controllers (ENC) with 4 Ports each

© Hitachi Vantara LLC 2021. All Rights Reserved.


DBN Physical View

DBN Drive Box Small


• 24 x SSD Drives 2.5“
• 2U height
• 2 x ENC
• 2 x PS
• 17 kg weight

SFF – Small Form Factor drives 2.5"


LFF – Large Form Factor drives 3.5”
ENC – Enclosure Controller
PS – Power Supply

© Hitachi Vantara LLC 2021. All Rights Reserved.


DBN Rear View

Status ENC BE-Ports


Status
ENC

PS

Note the four Back-End ports per ENC

© Hitachi Vantara LLC 2021. All Rights Reserved.


Fill in the Blank

A. 24

A DBN has __ 2.5” slots for mounting drives. B. 60

C. 48

D. 12

© Hitachi Vantara LLC 2021. All Rights Reserved.


Drive Box Specifications

© Hitachi Vantara LLC 2021. All Rights Reserved.


Maximum Drive Box Numbers

VSP VSP VSP VSP


VSP VSP VSP
Item G350, G370, G700, G900,
E590 E790 E990
F350 F370 F700 F900

DBS / DBL 7 11 36 48

DB60 4 6 20 24

DBF 36 48

DBN 4
Drive max. 264 384 1200 1440 24 24 96
DKB / CTL Embedded Port 2 2/4 Internal Port 2/4

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End Cabling

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End of VSP E990
 VSP E990 supports up to 4 DBs

 Disk Box type is DBN only

 2 pattern combination of CHB(FE) and DKBN(BE)


For these patterns, please refer to the next slide.

Parts Size
CTL 4U DB-03 DB(DBN)

DB DBN 2U DB-02 DB(DBN)


8U
The treatment of SVP is
(Up to 4) DB-01 DB(DBN)
the same as Panama 2: 12U
DB(DBN)
SVP Option (1U) SVP is optional DB-00

CBL
4U

© Hitachi Vantara LLC 2021. All Rights Reserved.


Back-End of VSP E990
• Two pattern combination of CHB(FE) and DKBN(BE)

CHB(FE) Rear view Number of DKBN Number of NVMe port


2 DKBNs / CTL 4 ports / CTL
4 DKBNs / System 8 ports / System
Pattern 1

2E 2F
1 or 2 DBs/ System

1E 1F
4 DKBNs / CTL 8 ports / CTL
8 DKBNs / System 16 ports / System
Pattern 2

2E 2F
3 or 4 DBs/ System

DKBN(BE)
1E 1F Pattern 3: diskless configuration.
© Hitachi Vantara LLC 2021. All Rights Reserved.
Back-End VSP E990

2 DKBs per CTL

4 DKBs per CTL


© Hitachi Vantara LLC 2021. All Rights Reserved.
Parity Groups

© Hitachi Vantara LLC 2021. All Rights Reserved.


Parity Groups (PG)

RAID Group (RG) Array group Error Checking and Correction (ECC) group

 Interfaces for PG creation are:


• Hitachi OPS Center Administrator
• Hitachi Storage Navigator (SN), with SVP only
• Hitachi Storage Advisor Embedded (HSAE)
• Command Line Interface (CLI) with SSH embedded (HM850, HM900 only)
• CLI with RAIDCOM (RM)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Drive Types

© Hitachi Vantara LLC 2021. All Rights Reserved.


Drive Offerings

Type Form Factor Size


1.9TB
3.8TB
SSD 2,5“
7.6TB
15TB

© Hitachi Vantara LLC 2021. All Rights Reserved.


Matching

1. ________ drives are not supported for HM900


arrays.
A. SAS 15k
2. VSP F350 and VSP F370 support ____ drives
only. B. SSD

© Hitachi Vantara LLC 2021. All Rights Reserved.


Encryption

© Hitachi Vantara LLC 2021. All Rights Reserved.


Encryption With 4U Controller Box Models

VSP Model Standard With Encryption


VSP G700, F700 DW-F800BS12G DW-F800BS12GE
VSP G900, F900
VSP E990 DKC-F910I-BN8G DKC-F910I-BN8GE

Note: Different DKB types for encrypted and non-encrypted environments.


© Hitachi Vantara LLC 2021. All Rights Reserved.
Encryption With 2U Controller Box

VSP Model Standard With Encryption


G350, F350 DW-F850-CTLS DW-F850-CTLSE
G370, F370 DW-F850-CTLSH DW-F850-CTLSHE
E590 DW-F900-CTLSN DW-F900-CTLSNE
E790 DW-F900-CTLMN DW-F900-CTLMNE

Note: Different CTL boards for encrypted and non-encrypted environments


© Hitachi Vantara LLC 2021. All Rights Reserved.
Your Takeaways

What are 1-2 takeaways from this module?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Key Takeaways

Supported Drive Types give the customer flexibility to put the focus on
either performance or maximum capacity

Several different tools are available to create Parity Groups

Encrypted Parity Groups provide highest level of security

Different RAID layouts keep Back-End configuration flexible

New NVMe Back-End provides maximum performance

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi VSP E Series
Refresher Workshop for
Certified Partners:
What’s New
Maintenance

© Hitachi Vantara LLC 2021. All Rights Reserved.


Module Objectives

 When you complete this module, you should be able to:


• Explain the differences in the maintenance of HM850 and HM900

© Hitachi Vantara LLC 2021. All Rights Reserved.


User Interface for
Maintenance

© Hitachi Vantara LLC 2021. All Rights Reserved.


Launch Maintenance Utility User Interface

 Maintenance utility can be invoked from the different locations:

Storage
Navigator/Web Maintenance IP
HSAE pull-down Ops Center
console/BEM Address on Web MPC
menu Administrator
with manual browser
drive selection

© Hitachi Vantara LLC 2021. All Rights Reserved.


MPC Software Tool

MPC GUI for


advanced tasks such All maintenance
as: tasks can be done
• New installation nondisruptively
without any power
• Edit array cycle
parameters, such as
ORM, SOM ORM - Online Read Margin,
Disk parameter for Dynamic
Sparing
SOM - System Option Mode
Customer Engineer (CE) has
additional MPC GUI for
advanced tasks

© Hitachi Vantara LLC 2021. All Rights Reserved.


Replacing Parts
Overview

© Hitachi Vantara LLC 2021. All Rights Reserved.


Preparation

 Generally, part replacements happen directly or indirectly

Direct replacements Indirect replacements

• No interaction with • A specific GUI operation


Maintenance Utility GUI required before and
after replacement

• Example: Drive • Example: Replacing


replacement controller, cache DIMM

© Hitachi Vantara LLC 2021. All Rights Reserved.


Parts Replacement
Alarm
Unit / Location Part Explanation MU Monitoring Direct Indirect
LED
Controller For S model X (*2) X X -- X (*2)
FAN FAN module (embedded) X X X -- X (*2)
DKC(2U) specific Battery Cache Backup Battery X X X X X (*3)
PSU Power Supply Unit X X X X X (*3)
CFM-Mid for S CFM-Mid for S X (*2) X X -- X (*2)
Controller For H model (2CPU), X (*2) X X -- X (*2)
FAN FAN Unit BKMF X X X X --
Battery Cache Backup Battery X X X X --
DKC(4U) specific PSU Power Supply Unit X X X X --
DKB Back-End I/O Module X (*2) X X -- X (*2)
CFM SSD, different capacities X (*2) X X -- X (*2)
Management port
LAN Board -- X X -- X (*2)
Maintenance port
DIMM DIMM 32GB, 64GB -- X X -- X (*2)
Fibre (32Gb/s x 4port)
CHB X (*2) X X -- X (*2)
Front-End I/F iSCSI (10Gb/s x 2port)
Fibre (16Gb/s), Fibre (32Gb/s)
SFP X X X X --
iSCSI (10Gb/s)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Direct Versus Indirect Replacement
Direct (Example: Drive replacement) Indirect (Example: CTL replacement)

Step#1: Detecting the failure Step#1: Detecting the failure


Alarm LED Alarm LED
SNMP, Email Remote Ops
(ON) (OFF)

Step#2: Identifying the failed parts Step#2: Identifying the failed parts

Step#3: Parts ordering Step#3: Parts ordering

Step#4: Replace the drive Step#4: Block the CTL from GUI

ON ON

Step#5: Replace the CTL

OFF
OFF Step#6: Recover CTL from GUI

Step#5: Confirming the recovery Step#7: Confirming the recovery

© Hitachi Vantara LLC 2021. All Rights Reserved.


Completion

Complete SIM (Alert) by opening list of Alerts in Maintenance Utility

Refresh Maintenance Utility to check, whether there are any other


issues indicated

Follow the policy for handling of broken parts

© Hitachi Vantara LLC 2021. All Rights Reserved.


True or False

1. MPC software is used for Channel Board replacement.

2. A failed DKB can be replaced directly.

3. HDD is replaced directly.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Your Takeaways

What are 1-2 takeaways from this module?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Key Takeaways

Maintenance can be done nondisruptively

Direct Replacement is replacing simple devices without software


procedure via Maintenance Utility

Indirect Replacement should always be initiated by Maintenance Utility

Hardware problems are indicated by LEDs, SIM, SNMP and exclamation


marks in the GUI
Some maintenance procedures (For example, DIMM replacement) can
cause performance issues

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi VSP E Series
Refresher Workshop for
Certified Partners:
What’s New
Management GUIs

© Hitachi Vantara LLC 2021. All Rights Reserved.


Module Objectives

 When you complete this module, you should be able to:


• Describe the different management GUIs available for Hitachi Virtual Storage
Platform (VSP) E series
• Explain the features Hitachi Storage Advisor Embedded (HSAE)
• Describe Secure Shell Access To DKC (CBX)

© Hitachi Vantara LLC 2021. All Rights Reserved.


GUI Overview

© Hitachi Vantara LLC 2021. All Rights Reserved.


GUI Overview

• Hitachi Ops Center Administrator


 VSP midrange
VM
 VSP G1000, VSP x1500 enterprise
 VSP 5000 series enterprise

• Hitachi Storage Advisor Embedded (HSAE)


Embedded
 Management for single array

• Hitachi Command Suite (HCS)


 All Hitachi storages
SVP required
• Storage Navigator (SN)
 Management for single array

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Ops Center

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Ops Center Overview

Hitachi Ops Center


Portfolio Products

• Administrator: Configure and provision systems


Administrator
• Analyzer: Monitor, optimize, plan and troubleshoot
• Automator: Orchestrate automated workflows
Analyzer • Data Protection: Enterprise copy data management

Automator

Protector

© Hitachi Vantara LLC 2021. All Rights Reserved.


Single Management Server

Management
Client Data Center
Management Server
Hitachi Ops Center Hitachi Ops Center Hitachi Ops Center
Automator Protector Analyzer Deploy by
Ops Center
Hitachi Ops Center API Hitachi Ops Center Hitachi Ops Center
OVA
Configuration Manager Analyzer Detail View Common Services

Hitachi Ops Center


Analyzer Probe Deploy by
Analyzer
RAID Agent Probe OVA

Storage Application Analyzer Probe


Systems Hosts server

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Storage Advisor
Embedded (HSAE)

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Storage Advisor Embedded

 HSAE runs on DKC and offers simple and


fast provisioning

 Accessible on management port or


maintenance port

 Enter IP Address of management port in


browser

 Enter URL with maintenance port in browse

Access via Maintenance Port:


http://<Ip-Ctl>/StorageAdvisorEmbedded
© Hitachi Vantara LLC 2021. All Rights Reserved.
Hitachi Storage Advisor Embedded

 Launching Maintenance Utility

© Hitachi Vantara LLC 2021. All Rights Reserved.


Hitachi Storage Advisor Embedded

Servers: Register Server and provide Volumes


Volumes: DP-Volumes (no Basic Volumes)
Pools: Selection of drives, creating Parity Groups
and LDEV addressing by HSAE
Ports: Configuration of Ports
Spares: Assigning and De-assigning

© Hitachi Vantara LLC 2021. All Rights Reserved.


Basic LDEVs in HSAE

Basic LDEVs are created only, while Parity Groups are built for creating and expanding pools

Basic LDEVs for other purposes (CMD, Provisioning) require different tools
(Ops Center, Command Suite, Storage Navigator, RAIDCOM, REST API).

Basic LDEVs are addressed top-down (for example, CU:ID will be FE:FF, FE:FE, FF:FD
and so on)

Maximum size of a Basic LDEV: 2.99 TB

With MPC, which is a CE tool, there is still a Storage Navigator (Webconsole) for SVP-less
storages

© Hitachi Vantara LLC 2021. All Rights Reserved.


SSH Server

© Hitachi Vantara LLC 2021. All Rights Reserved.


Secure Shell to Controller

HM850 and HM900 provide a direct SSH interface to GUM (CTL)

Only configuration commands are possible, no replication

SSH listens on port 20522

© Hitachi Vantara LLC 2021. All Rights Reserved.


Secure Shell to Controller

 Open a SSH session to controller IP, port 20522

© Hitachi Vantara LLC 2021. All Rights Reserved.


Secure Shell to Controller

 Login and issue commands

Manual for RAIDCOM commands in PDL (Example):


CCI_v01_48_03_03_Command_Reference_MK-90RD7009-38
© Hitachi Vantara LLC 2021. All Rights Reserved.
Quick Question

Where is Hitachi Ops Center Administrator located?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Your Takeaways

What are 1-2 takeaways from this module?

© Hitachi Vantara LLC 2021. All Rights Reserved.


Key Takeaways

All actual Hitachi midrange series have HSAE embedded on the CTL
boards

Storage Navigator is not available for SVP-less storages

HSAE supports provisioning, snapshots and global-active device (GAD)


settings
All Hitachi midrange storage systems can be registered in Ops Center
Administrator

HSAE doesn´t support Basic LDEVs creation

© Hitachi Vantara LLC 2021. All Rights Reserved.


Learning Path

https://learningcenter.hds.com/private/i1t/Ops_Center
_Learning_Path_links_Bnr2_Oct2020.pdf

© Hitachi Vantara LLC 2021. All Rights Reserved.


Bookmark

© Hitachi Vantara LLC 2021. All Rights Reserved.


How did we do?
We value your feedback.

Check your email for the class survey


or ask your instructor.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Communicating in
a Virtual
Classroom

© Hitachi Vantara LLC 2021. All Rights Reserved.


Communicating in a Virtual Classroom

 Chat

 Q&A

 Feedback Options
− Raise Hand
− Yes/No
− Emoticons

 Markup Tools
− Drawing Tools
− Text Tool
© Hitachi Vantara LLC 2021. All Rights Reserved.
Audio in the WebEx Session

© Hitachi Vantara LLC 2021. All Rights Reserved.


Feedback Features — Try Them

Raise Hand Yes No Emoticons

© Hitachi Vantara LLC 2021. All Rights Reserved.


Markup Tools (Drawing and Text) — Try Them

Pointer Text Writing Drawing Highlighter Annotation Eraser


Tool Tools Colors

© Hitachi Vantara LLC 2021. All Rights Reserved.


Using the Hands-on Lab in WebEx

© Hitachi Vantara LLC 2021. All Rights Reserved.


Using the Hands-on Lab in WebEx, cont.

© Hitachi Vantara LLC 2021. All Rights Reserved.


Other WebEx Training Center (TC) Notes

 Audio will transfer to the lab – prompted

 Best to have a separate monitor for lab guide

 Please remember to click the hand icon again to put it down

© Hitachi Vantara LLC 2021. All Rights Reserved.


Intercall (WebEx) Technical Support

Call 800.374.1852

© Hitachi Vantara LLC 2021. All Rights Reserved.