Download as docx, pdf, or txt
Download as docx, pdf, or txt
You are on page 1of 93

LURÍN DISTRICT – LIMA

PROMOTION INMOBILIARIA DEL SUR SA


MAY 2019
EITH
Southern Real Estate Promotion
SA ER
CINSUCO

SOIL STUDY SOIL MECHANICS FOR PURPOSES


PAVEMENT -
MACROPOLIS URBAN ENABLEMENT STAGE 2
EITH
Southern Real Estate Promotion
SA ER
CINSUCO
Content

For the development of this study, a field campaign has been carried out consisting of
the excavation of 17 pits, whose locations are conveniently distributed in areas of
interest................................................................................................................................2
Table 2.1 shows the pits carried out for this report............................................................2
Annex A shows the locations of the pits............................................................................2
Standard soil classification and physical properties tests were carried out with the altered
samples obtained from the excavations (pit pits)...............................................................3
The tests were carried out following the standards of the American Society For Testing
and Materials (ASTM). The standards for these tests are the following:...........................3
Granulometric analysis by sieving.....................................................................................3
Moisture content.................................................................................................................3
AASHTO Classification.....................................................................................................3
Table 3.1 presents a summary of the results of the standard tests performed....................3
CALICATA C-11....................................................................................................................25
CINSUCO.......................................................................................................................................48
CINSUCO....................................................................................................................................52
ESSAY REPORT...........................................................................................................130
The use of the Intomacon contained in document *' of exeusiva responsabiidadoel solctants............................................58
ESSAY REPORT...........................................................................................................330
Photo N° 01: Panoramic view of pit C-1...............................................................................1
Photo N° 02: Panoramic view of pit C-2...............................................................................2
Photo N° 03: Panoramic view of pit C-3...............................................................................3
Photo N° 04: Panoramic view of pit C-4...............................................................................4
Photo N° 05: Panoramic view of pit C-5...............................................................................5
Photo N° 06: Panoramic view of pit C-6...............................................................................6
Photo N° 07: Panoramic view of pit C-7...............................................................................7
Photo N° 08: Panoramic view of pit C-8...............................................................................8
Photo N° 09: Panoramic view of pit C-9...............................................................................9
Photo N° 10: Panoramic view of pit C-10...........................................................................10
Photo N° 11: Panoramic view of pit C-11...........................................................................11
Photo N° 12: Panoramic view of pit C-12...........................................................................12
Photo N° 13: Panoramic view of pit C-13...........................................................................13
Photo N° 14: Panoramic view of pit C-14...........................................................................14
Photo N° 15: Panoramic view of pit C-15...........................................................................15
EITH
Southern Real Estate Promotion
SA ER
CINSUCO
ANNEXES

Annex A: Blueprints
Annex B: Excavation Record
Annex C: Laboratory Test Results
Annex D: Photographic record

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019
EITH
Southern Real Estate Promotion
SA ER
1. GENERALITIES CINSUCO

1.1 Introduction

Promotion Inmobiliaria del Sur SA (hereinafter Client) requested CINSUCO SAC (hereinafter
Consultant) the completion of the Soil Study for Paving Purposes of Stage 2, located in
Macrópolis Urban Enabling Stage 2 - Lurín District.

For the development of this report, the client has provided the Soil and Pavement Mechanics
Study of the Macrópolis Industrial Habilitation carried out by Eng. Juan Velásquez Díaz in August
2015 and the soil and paving study of sub-lot 41 carried out by CINSUCO SAC in July 2018.

1.2 Location of the Study Area

The project area is developed on the Periurbana roads, axes A and B, Av. Fernando Romero,
Lomas de Pucará and Calle Ramiro Llona that serve as accesses in Stage 2, which correspond
to the Macrópolis Urban Habilitation Stage 2, District of Lurín, Province and Department of Lima.
See Annex A where the location of the study area is shown. Annex A presents

1.3 Goals

The purpose of this study is to carry out an evaluation of the geotechnical conditions of the
subgrade soil components of the Periurbana roads, axes A and B, Av. Fernando Romero, Lomas
de Pucará and Calle Ramiro Llona which surround sub-lot 41. This evaluation is aimed at
defining the physical, chemical and mechanical characteristics of the subsoil, to establish the
parameters that govern its resistance to load requests.

The work program carried out for this purpose has consisted of:

□ Execution of Calicatas in the land area.


□ Taking altered samples.
□ Execution of laboratory tests.
□ Analysis of field and laboratory work.
□ Conclusions and recommendations.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

1
EITH
Southern Real Estate Promotion
SA ER
2. GEOTECHNICAL RESEARCH CINSUCO

2.1 Calicatas Excavation

For the development of this study, a field campaign has been carried out consisting of the
excavation of 17 pits, whose locations are conveniently distributed in areas of interest.

Table 2.1 shows the pits carried out for this report.

Table 2.1
Summary of pits
UTM Coordinates – WGS 84
Location Calicata Water Rock level Total Depth
North This
level (m) (m) (m)
Ramiro Llona C-01 8646226 303259 NE NE 1.50
Street CINSUCO C - 02 NE NE 1.50
8646042 303262
2018
C - 03 8645827 303269 NE NE 1.50
C - 04 8645724 303257 NE NE 1.50
C - 05 8645764 303197 NE NE 1.50
Av. Fernando
Romero C - 06 8645704 303137 NE NE 1.50
CINSUCO 2018 C - 07 8645757 303073 NE NE 1.50
C - 08 8645706 302984 NE NE 1.50
C - 09 8645778 302958 NE NE 1.50
C - 10 8645842 302931 NE NE 1.50
C - 11 8645903 302963 NE NE 1.50

Av. Periurbana C - 12 8645950 302927 NE NE 1.50


CINSUCO 2018 C - 13 8645997 302961 NE NE 1.50
C - 14 8646058 302922 NE NE 1.50
C - 15 8646133 302946 NE NE 1.50

C - 16 8646226 303259 NE NE 1.50

Av. Lomas de CCC – 08 8646562 302630 NE NE 2.10


Pucara
Eng. John 2015 CCC – 09 8646856 302900 NE NE 2.20

Abbreviations:
NE: Not found
Depth : Depth
Prog.: Progressive

Annex A shows the locations of the pits.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

2
CINSUCO
Southern Real Estate Promotion
SA
3. LABORATORY TESTS

3.1 Standard tests

Standard soil classification and physical properties tests were carried out with the altered
samples obtained from the excavations (pit pits).

The tests were carried out following the standards of the American Society For Testing and
Materials (ASTM). The standards for these tests are the following:

Granulometric analysis by sieving ASTM D-422


Moisture content ASTM D-2216
AASHTO Classification AASHTO M-145

Table 3.1 presents a summary of the results of the standard tests performed.

Table 3.1
Summary of standard soil classification tests

Classification
Granulometry (%) Boundaries (%) c. H.
Company Calicata Deep (m) Gravel Sand Fine L.L. IP (SUCS)
Sample (%)
C-01 M -1 0.40-1.50 42.3 34.5 23.2 NP NP 1.7 G.M.
C-02 M -1 0.00-1.10 25.3 73.3 1.3 NP NP 1.3 SP
C-03 M -1 0.30-1.50 40.8 37.5 21.7 NP NP 1.4 G.M.
C-04 M -1 0.50-1.50 45.5 38.1 16.4 NP NP 1.5 G.M.
C-05 M -1 0.30-1.50 46.4 40.4 13.2 NP NP 1.2 G.M.
C-06 M -1 0.00-1.50 44.9 46.2 8.9 NP NP 1.4 SP-SM
C-07 M -1 1.10-1.50 58.0 32.4 9.6 NP NP 0.9 GP-GM
CINSUC O
C-08 M -1 0.80-1.40 49.8 32.4 17.8 NP NP 1.1 G.M.
2018
C-09 M -1 0.10-1.50 53.5 30.7 15.8 NP NP 1.5 G.M.
C-10 M -1 0.40-1.50 72.5 23.7 3.8 NP NP 0.9 GP
C-11 M -1 1.00-1.50 64.8 23.2 12.0 NP NP 1.0 GP-GM
C-12 M -1 0.20-1.50 61.7 36.3 1.9 NP NP 0.8 G.W.
C-13 M -1 0.10-0.50 17.5 39.4 43.1 NP NP 5.5 YE
C-14 M -1 0.20-1.50 67.9 26.4 5.7 NP NP 1.2 GP-GM
C-15 M -1 0.50-1.10 14.7 48.1 37.2 NP NP 6.3 SC-SM
Eng. Juan CCC-08 M -1 0.20-2.10 69.0 27.0 4.0 NP NP 11.9 GP
2015
CCC-09 M -1 0.20-2.20 71.0 25.0 4.0 NP NP 2.3 GP

Abbreviations:
NP: Does not present
LL: Liquid limit
SUCS.: Unified Soil Classification System
IP: Plasticity index
CH: Moisture content
SOIL MECHANICS REPORT EMS – 08
Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

The laboratory test certificates are presented in Annex C.

3.2 Special tests

3
EITH
Southern Real Estate Promotion
SA ER
Tests to define mechanical properties make it possible to determine the resistance of soils or
CINSUCO
their behavior against load requests.

The special tests were carried out following the standards of the American Society For Testing
and Materials (ASTM). The standards for these tests are the following:

- Modified Proctor Test (ASTM D-1557)


- California Bearing Ratio – CBR (ASTM D-1883)

Table 3.2 presents the summary of the proctor and CBR test.

Table 3.2
Proctor and CBR Test Summary
Modified Proctor CBR (0.1”)
Calicata Sample Prof. (m)
MDS (Kg/ cm3
) OCH (%) 95%(MDS) 100%(MDS)
C-01 M-1 0.40 – 1.50 2.20 8.20 48.50 71.50

C-09 M-1 0.10 – 1.40 2.23 8.90 54.00 81.50

C-13 M-1 0.10 – 0.50 2.03 11.1 31.5 38.90

Abbreviations:
MDS: Maximum dry density
OCH: Optimal moisture content

The Modified Proctor test and CBR are presented in Annex C.

3.3 Soil Chemical Tests

In order to estimate the degree of aggressiveness of the soil to the foundations of structures, soil
chemical tests have been carried out, where the sulfates, total soluble salts and chlorides
contained in the soil samples have been determined. Table 3.3 presents the summary of the
chemical tests.

Table 3.3
Chemical Test Summary

Chlorides
Poll/Sample Depth (m) TSS (ppm) Sulfates (ppm)
(ppm)

C - 02 / M - 1 0.00 – 1.10 12450.00 1377.48 2401.79

C - 06 / M - 1 0.00 – 1.50 20430.00 3730.67 1162.03

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

Chlorides
Poll/Sample Depth (m) TSS (ppm) (ppm) Sulfates (ppm)
C - 12 / M - 1 0.20 – 1.50 4611.00 1291.38 432.25

Abbreviations:
TSS: Total Soluble Salts ppm: Parts per million

4
CINSUCO
Southern Real Estate Promotion
SA
The laboratory test certificates are presented in Annex C.

4. SOIL PROFILE

Based on the excavation records and surface inspection of the land, the following conformation is
deduced.

The stratigraphic profile in the study area was found:

Av. Periurban Axis A and B. - It presents a cover of loose silty sand material whose thickness
varies from 0.10 m to 0.50 m. Underlying a granular material made up of silty clay sand, silty
sand, silty gravel, poorly graded gravel with silt and well graded gravel whose SUCS classification
is SC-SM, SM, GM, GP-GM and GW, of zero to low plasticity, moderately dense, slightly humid,
subangular and angular gravel, with the presence of pebbles of maximum size 11”, also
presenting lenses of fine material, up to an excavation depth of 1.50 m.

Av. Fernando Romero . - It presents a cover of loose silty sand material whose thickness varies
from 0.20 m to 0.60 m. Underlying is a granular material made up of poorly graded sand with silt,
silty sand and silty gravel whose SUCS classification is SP-SM, SM and GM, of zero to low
plasticity, medium dense, slightly humid, subangular and angular gravel, with the presence of
bologna. maximum size 8”, up to an excavation depth of 1.50 m.

Av. The Lomas de Pucará . - It presents a coverage of loose silty sand material, thickness is
0.20 m. Underlying is a granular material made up of poorly graded gravel with sand whose
SUCS classification is GP, of zero to low plasticity, moderately dense, slightly moist, subangular
and angular gravel, with the presence of bollards of maximum size 8", up to the excavation depth
of 2.20 m.

Ramiro Llona Street . - It presents a cover of loose silty sand material whose thickness varies
from 0.30 m to 0.40 m. Underlying is a granular material made up of well-graded sand and silty
gravel whose SUCS classification is SW and GM, of zero to low plasticity, moderately dense,
slightly humid, subangular and angular gravel, with the presence of pebbles of maximum size 10",
up to the depth. excavation of 1.50 m. In the pit, a very dense altered rock material was found,
which is why it was only possible to excavate up to 1.10 m deep.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

No water table has been recorded in any of the pits up to the excavation level of 1.50 m. Annex B
presents the excavation records where the different types of material present in the pits can be
identified, and Annex A presents the plan location of the pits.

5. CHEMICAL EVALUATION

The following table presents the permissible limits recommended by the ACI Committee 318-83
and values compiled from existing literature on the amounts in parts per million (ppm) of total
soluble salts, as well as the degree of alteration and observations of the attack. For reinforcement
and concrete, the necessary recommendations are given for protection against chemical attack.

5
EITH
Southern Real Estate Promotion
SA ER
Table 5.1 CINSUCO
Permissible limits
Presence in the Grade of
ppm Consequence
Soil of: Disturbance

0-1000 1000- Mild


2000 2000- Moderate Causes a chemical attack on the concrete of the
*Sulfates
20,000 >20,000 Severe foundation
Very Severe

It causes corrosion problems for armor or metal


**Chlorides >6,000 Harmful
elements.
Causes problems of loss of mechanical

**Total Soluble Salts >15,000 Harmful resistance due to leaching problem

* ACI Committee 318-83


**Existing experience

From the comparison of the results obtained in the laboratory tests and the recommended values,
the following behavior can be deduced.

In the study area, the levels of chemical elements are above the minimum permissible values, so
the use of Type V Portland Cement is recommended for concrete structures and reinforcement.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

6
CINSUCO Real Estate
Promotion of the South SA

6. CONCLUSIONS AND RECOMMENDATIONS

Conclusions:

6.1 This report presents the field work carried out, where samples were taken and are being tested.

6.2 The field work consisted of executing the following program:


□ 17 Calicatas were made with depths ranging up to 2.20 m deep, carried out manually.
□ In the survey, the Calicata registry was carried out, sampling of altered soil for the execution
of standard tests, special tests and chemicals.

6.3 From the results of the field work and laboratory tests, it can be mentioned that the area under
study has cover material (loose silty sand), if the subgrade level falls in this material it must be
replaced with loan material before of the pavement conformation, this material varies from 0.20 m
to 0.60 m in depth, then represents a material of silty clay sand, well graded sand, poorly graded
sand with silt and sand, silty sand, well graded gravel, silty gravel and well graded gravel. harrow,
no water table has been found up to the excavation depth of 2.20 m. Descriptions of the strata
found are presented in Annex B.

6.4 The contents of salts, sulfates and chlorides are above the permissible limits, so there will be
severe attack on the concrete and reinforcing steel, therefore, Type V Portland cement must be
used.

Recommendations:

6.6 Given the presence of fine material in the subgrade, it is recommended to avoid water leaks, so
that they do not affect the subgrade, causing saturation of the soil and thereby causing settlement
that damages the pavement.

6.7 Surface water management is recommended, due to the existence of green areas planned in the
study area.

6.8 It is recommended to seal the joints in the curbs and/or elements that confine the roads to
prevent irrigation water or others from washing away the base and subgrade fines.
6.9 The results of this report apply exclusively to the area studied and cannot be used in other
sectors or for other purposes.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

7
Southern Real Estate Promotion
SA

REFERENCES

1. Alva Hurtado J. (1992), “Soil Mechanics Applied to Foundations”, ACI-UNI Student Chapter, Lima.

2. Lambe TW and Whitman R.V. (1969), “Soil Mechanics”, John Wiley, New York.

3. Terzaghi K. and Peck R.B. (1967), “Soil Mechanics in Engineering Practice”, John Wiley, New
York.

4. Vesic A. (1973), “Analysis of the Bearing Capacity of Shallow Foundations”, JSMFED, ASCE, Vol.
99.

5. National Building Regulations (2006)”, “Technical Building Standard E-30 - Earthquake Resistant
Design”, Lima - Peru.

6. National Regulations on Foundations (1997), “Standard E-050 on Soils and Foundations”, Lima-
Peru.

7. Packard, Robert G., Slab Thickness Design for Industrial Concrete Floors on Grade, IS195.01D,
Portland Cement Association, Skokie, IL, 1976.

8. Panak, Jhon j., and Rauhut, JB , “Behavior and Design of Industrial Slabs on Grade”, ACI
JOURNAL, Proceedings V.72, N°5, May 1975. pp. 219-224.

degree of alteration and the observations of the attack on the reinforcement and concrete, the
necessary recommendations are given for protection against chemical attack.

SOIL MECHANICS REPORT EMS – 08


Soil Studies for Paving Purposes Macrópolis Urban Rehabilitation Project Stage 2 Lurín District May 2019

8
ANNEX A: PLANS
ANNEX B: EXCAVATION RECORD
Location : Av. Lomas de Pucara
EXCAVATION RECORD CALICATA CCC-08
Excavation date : May 2015 (Page 1 of 1)
Registration date : May 2015
Method : Mechanical equipment
Soil Studies for Paving Purposes Equipment : CAT
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 1.00m x 1.80m
: Eng. Juan Velasquez
District Registered by Reviewed : Eng. Juan Velasquez
and Approved
Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 2.10
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
0
Silty sand, low plasticity, loose, slightly moist, SM light brown Covering material.

Gravel poorly graded with sand, low to no plasticity, moderately


dense, slightly moist, light gray, subangular and angular, presence
of bolls with a maximum size of 8".

GP

3
Location : Av. Lomas de Pucara
EXCAVATION RECORD CALICATA CCC-09
Excavation date : May 2015 (Page 1 of 1)
Registration date : May 2015
Method : Mechanical equipment
Soil Studies for Paving Purposes Equipment : CAT
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 1.00m x 1.80m
: Eng. Juan Velasquez
District Registered by Reviewed : Eng. Juan Velasquez
and Approved
Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 2.20
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
Silty sand, low plasticity, loose, slightly moist, light brown. Covering material.
YE

Gravel poorly graded with sand, low to no plasticity, moderately


dense, slightly moist, light gray, subangular and angular, presence of
bolls with a maximum size of 8".

GP

3
Location : 16 New Street
CALICATA C-01
Excavation date : June 2018
Registration date : June 2018 (Page 1 of 1)
CINSUCO Method : Manual
ENGINEERING AND GEOTECHNICS

Soil Studies for Paving Purposes Equipment :-----


Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 0.80m x 1.00m
District Registered by Reviewed : RTA
and Approved : JSG
Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Silty gravel with sand, low to no plasticity, moderately dense, slightly


moist, light gray, subangular and angular, presence of bolls of
maximum size 10".

:::::

G.M.
1

2
Location : 16 New Street
CALICATA C-02
Excavation date : June 2018
Registration date : June 2018 (Page 1 of 1)
CINSUCO Method : Manual
ENGINEERING AND GEOTECHNICS

Soil Studies for Paving Purposes Equipment :-----


Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 0.80m x 1.00m
District Registered by Reviewed : RTA
and Approved : JSG
Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,10
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
Well graded sand, zero plasticity, dense, light gray, slightly moist,
angular gravel. Residual rock (moderately altered).

S.W.

Rejection of excavation (very dense


material).

2
Location : 16 New Street
CALICATA C-03
Excavation date : June 2018
Registration date : June 2018 (Page 1 of 1)
CINSUCO Method : Manual
ENGINEERING AND GEOTECHNICS

Soil Studies for Paving Purposes Equipment :-----


Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 0.80m x 1.00m
District Registered by Reviewed : RTA
and Approved : JSG
Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Silty gravel with sand, low to no plasticity, moderately dense, slightly


Yo moist, dark brown, subangulosa and angular, presence of bolonería
of maximum size of 8".

Clay lenses.

G.M.
1

2
CALICATA C-04
Location : Av. Fernando Romero
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80mx 1.00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Surface flat Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
0
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Silty gravel with sand, low to no plasticity, moderately dense,


slightly moist, dark brown, subangulosa and angular, presence of
bolonería of maximum size of 8". Clay lenses.

G.M.
1

2
CALICATA C-05
Location : Av. Fernando Romero
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80mx 1.00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Surface flat Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Poorly graded sand with silt and gravel, low plasticity, moderately
dense, slightly moist, light brown, coarse-grained sand.

SP-SM

Silty gravel with sand, low to no plasticity, moderately dense, slightly


moist, light brown, subangular and angular, presence of bolls with a
maximum size of 8".

G.M.
1

2
CALICATA C-06
Location : Av. Fernando Romero
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80mx 1.00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Surface flat Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Sand poorly graded with silt and gravel, low to no plasticity,
moderately dense, slightly moist,
light brown, coarse-grained sand.

Clay lenses.

SP-SM

2
CALICATA C-07
Location : Av. Fernando Romero
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80mx 1.00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Surface flat Prof. calicata (m) : 1,50

Sample condition
Disturbed
In block

Sample code
Depth (m)

2
sons

Sample
5 Description Comments
0
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Poorly graded gravel with silt and sand, low to no plasticity,


moderately dense, slightly moist, light gray, subangular and
angular, presence of bolls with a maximum size of 9".

1
GP-GM

2
CALICATA C-08
Location : Av. Fernando Romero
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80mx 1.00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Surface flat Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Poorly graded gravel with silt and sand, low to no plasticity,


moderately dense, slightly moist, light gray, subangular and angular,
presence of bolls of maximum size 12".

GP-GM

Silty gravel with sand, low to no plasticity, moderately dense, slightly


moist, light brown, subangular and angular, presence of bolls with a
maximum size of 8".

G.M.

2
CALICATA C-09
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
Silty sand, low plasticity, loose, slightly moist, light brown.
YE Covering material.

Silty gravel with sand, low to no plasticity, moderately dense,


slightly moist, light gray, subangular and angular, presence of bolls
of maximum size 8".

G.M.

2
CALICATA C-10
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Silty sand, low plasticity, medium dense, slightly humid, light brown.

YE Clay lens.

Gravel poorly graded with sand, no plasticity, moderately dense,


slightly moist, light gray, subangular and angular, presence of bolls
with a maximum size of 8".

GP
1

2
Location : Av. Periurban
CALICATA C-11
: June 2018 (Page 1 of 1)
Excavation date : June 2018 :
CINSUCO Registration date
Manual
ENGINEERING AND GEOTECHNICS Method
Soil Studies for Paving Purposes Equipment :-----
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Calicata dimension : 0.80m x 1.00m
District Registered by Reviewed : RTA
Water table (m) : Not found :
and Approved : JSG
Pit depth (m) 1.50
Southern Real Estate Promotion SA Surface condition : Flat surface
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
0
Silty sand, low plasticity, loose, slightly moist, light brown.
YE Covering material.

Silty sand, low plasticity, medium dense, slightly humid, light brown.

YE Clay lens.

Silty gravel with sand, low to no plasticity, moderately dense,


slightly moist, dark brown, subangulosa and angular, presence of
bolonería of maximum size of 6".

G.M.

1
Poorly graded gravel with silt and sand, low to no plasticity,
moderately dense, slightly moist, light gray, subangular and
angular, presence of bolls of maximum size 8".

GP-GM

2
CALICATA C-12
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
YE Covering material.

Well-graded gravel with sand, no plasticity, moderately dense,


slightly moist, light gray, subangular and angular, presence of bolls
of maximum size 12".

G.W.
1

2
CALICATA C-13
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, SM light brown
Covering material.

Silty sand with gravel, zero plasticity, moderately dense, slightly


humid, light brown.

YE

Poorly graded gravel with silt and sand, no plasticity, moderately


dense, slightly moist, light gray, subangular and angular, presence
of bolls with a maximum size of 9".

GP-GM
1

2
CALICATA C-14
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
2
Depth (m)

Sample
sons

5 Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Poorly graded gravel with silt and sand, no plasticity, moderately


dense, slightly moist, light gray, subangular and angular, presence
of bolls with a maximum size of 10".

1 GP-GM

2
CALICATA C-15
Location : Av. Periurban
(Page 1 of 1)
CINSUCO
ENGINEERING AND GEOTECHNICS Excavation date: June 2018
Soil Studies for Paving Purposes Registration date : June 2018
Macrópolis Project - Sub lot 41 Macrópolis, Lurín Method : Manual
Equipment : ----
District Calicata dimension : 0.80 max 1,00 m
Registered by : RTA
Reviewed and approved : JSG Water table (m) : Not found
Southern Real Estate Promotion SA Surface condition : Flat surface Prof. calicata (m) : 1,50
Sample condition
Disturbed
In block

Sample code
Depth (m)

Graphic

Sample
SUCS

Description Comments
TO
Silty sand, low plasticity, loose, slightly moist, light brown.
Covering material.

YE

Silty clay sand with gravel, low plasticity, moderately dense, slightly
moist, dark brown.

SC-SM

1
Poorly graded gravel with silt and sand, no plasticity, moderately
dense, slightly moist, light gray, subangular and angular, presence
of bolls with a maximum size of 7".
GP-GM

2
ANNEX C: RESULTS OF TESTS
LABORATORY
STANDARD CLASSIFICATION TESTS
(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-01
FLUIDITY DIAGRAM
Sample M-01

Depth (m) 0.40-1.50


Mesh % %
ANALYSIS BY SIEVING ASTM-D422

Retained %
Opening Accumulate What's
Weight Detained
(mm) d Withheld happeni
No. ng
3" 76.200 0.0 0.0 1.1 100.0
ULATED PERCENTAGE
AT'S HAPPENING (%)

2" 50.800 7.0 1.1 1.1 98.9


1 1/2 " 38.100 12.0 1.8 2.9 97.1
1" 25.400 23.0 3.5 6.4 93.6
3/4" 19.100 40.0 6.1 12.4 87.6 0.00 —
10.00 100.00
3/8" 9.520 87.0 13.2 25.6 74.4 Hit number
No. 4 4.760 110.0 16.7 42.3 57.7
GRANULO
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

SOIL MECHANICS LABORATORY


STANDARD CLASSIFICATION TESTS
(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-02
FLUIDITY DIAGRAM
Sample M-01

Depth (m) 0.00-1.10

% %
Mesh Retained % Accumulate What's
Opening Weight Detained
d Withheld happeni
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

No. ng
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.0 100.0


2" 50.800 0.0 0.0 0.0 100.0
PERCENTAGE

1 1/2 " 38.100 0.0 0.0 0.0 100.0


1" 25.400 0.0 0.0 0.0 100.0
3/4" 19.100 10.0 1.5 1.5 98.5 0.00 —
10.00 100.00
3/8" 9.520 62.0 9.4 10.9 89.1 Hit number
No. 4 4.760 95.0 14.4 25.3 74.7
No. 10 2.000 165.0 25.0 50.3 49.7
No. 20 0.840 140.0 21.2 71.6 28.4 Granulometric Distribution
No. 40 0.425 80.0 12.1 83.7 16.3
No. 60 0.250 65.0 9.9 93.6 6.4
No. 140 0.106 27.9 4.2 97.8 2.2 GG% 1.5
No. 200 0.075 5.7 0.9 98.7 1.3 % Gravel GF% 23.8 25.3
ASTM-D2216 Moisture Content (%) 1.3 AG% 25.0
% Sand A.M% 33.4
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 15.0 73.3
Plastic Index (IP) (%) - % Fine 1.3
Classification (SUCS ) : SP
Classification (AASHTO): A-1-a
Group Index: 0
Group Name
Description (AASHTO): GOOD Poorly graded sand with gravel

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-03 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.30-1.50
Mesh % %
Retained %
Opening do Accumulate What's
No. Weight Retain
d Withheld happeni
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

ng
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.8 100.0


2" 50.800 5.0 0.8 0.8 99.2
PERCENTAGE

1 1/2 " 38.100 8.0 1.2 2.0 98.0


1" 25.400 25.0 3.8 5.8 94.2
3/4" 19.100 45.0 6.8 12.6 87.4 0.00 —
10.00 100.00
3/8" 9.520 76.0 11.5 24.1 75.9 Hit number
No. 4 4.760 110.0 16.7 40.8 59.2
No. 10 2.000 95.0 14.4 55.2 44.8
No. 20 0.840 79.6 12.1 67.3 32.7 Granulometric Distribution
No. 40 0.425 30.0 4.5 71.8 28.2
No. 60 0.250 17.0 2.6 74.4 25.6
No. 140 0.106 20.0 3.0 77.4 22.6 GG% 12.6
No. 200 0.075 5.7 0.9 78.3 21.7 % Gravel GF% 28.2 40.8
Moisture Content ASTM-D2216 (%) 1.4 AG% 14.4
% Sand A.M% 16.6
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 6.5 37.5
Plastic Index (IP) (%) - % Fine 21.7
Classification (SUCS ) : G.M.
Classification (AASHTO): A-1-b
Group Index: 0
Group Name
Description (AASHTO): GOOD Silty gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

SOIL MECHANICS LABORATORY


STANDARD CLASSIFICATION TESTS
(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-04 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.50-1.50

% %
Mesh
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Retained %
Opening Accumulate What's
Weight Detained
(mm) d Withheld happeni
No. ng
3" 76.200 0.0 0.0 0.8 100.0
ACCUMULATED PERCENTAGE
WHAT'S HAPPENING (%)

2" 50.800 5.0 0.8 0.8 99.2


1 1/2 " 38.100 10.0 1.5 2.3 97.7
1" 25.400 25.0 3.8 6.1 93.9
3/4" 19.100 60.6 9.2 15.3 84.7
3/8" 9.520 93.7 14.2 29.5 70.5 Hit number
No. 4 4.760 105.7 16.0 45.5 54.5
No. 10 2.000 95.0 14.4 59.9 40.1
No. 20 0.840 80.0 12.1 72.0 28.0 Granulometric Distribution
No. 40 0.425 30.0 4.5 76.6 23.4
No. 60 0.250 20.5 3.1 79.7 20.3
No. 140 0.106 20.0 3.0 82.7 17.3 GG% 15.3
No. 200 0.075 5.7 0.9 83.6 16.4 % Gravel GF% 30.2 45.5
ASTM-D2216 Moisture Content (%) 1.5 AG% 14.4
% Sand A.M% 16.7
Liquid Limit (LL) ASTM-D4318 (%) 19
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 7.0 38.1
Plastic Index (IP) (%) NP % Fine 16.4
Classification (SUCS ) : G.M.
Classification (AASHTO): A-1-b
Group Index: 0
Group Name:
Description (AASHTO): GOOD Silty gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-05
FLUIDITY DIAGRAM
Sample M-01

Depth (m) 0.30-1.50

% %
Mesh Retained % Accumulate What's
Opening Weight Detained
d Withheld happeni
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

No. ng
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.0 100.0


2" 50.800 0.0 0.0 0.0 100.0
PERCENTAGE

1 1/2 " 38.100 10.0 1.5 1.5 98.5


1" 25.400 5.0 0.8 2.3 97.7
3/4" 19.100 60.6 9.2 11.5 88.5 0.00 —
10.00 100.00
3/8" 9.520 93.7 14.2 25.7 74.3 Hit number
No. 4 4.760 136.7 20.7 46.4 53.6
No. 10 2.000 110.0 16.7 63.1 36.9
No. 20 0.840 80.0 12.1 75.2 24.8 Granulometric Distribution
No. 40 0.425 30.0 4.5 79.8 20.2
No. 60 0.250 20.5 3.1 82.9 17.1
No. 140 0.106 20.0 3.0 85.9 14.1 GG% 11.5
No. 200 0.075 5.7 0.9 86.8 13.2 % Gravel GF% 34.9 46.4
ASTM-D2216 Moisture Content (%) 1.2 AG% 16.7
% Sand A.M% 16.7
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 7.0 40.4
Plastic Index (IP) (%) - % Fine 13.2
Classification (SUCS ) : G.M.
Classification (AASHTO): A-1-a
Group Index: 0
Group Name
Description (AASHTO): GOOD Silty gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-06 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.00-1.50

% %
Mesh Retained % What's
Opening do Accumulate
Weight Retain
No. d Withheld happenin
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

g
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.0 100.0


2" 50.800 0.0 0.0 0.0 100.0
PERCENTAGE

1 1/2 " 38.100 0.0 0.0 0.0 100.0


1" 25.400 5.0 0.8 0.8 99.2
3/4" 19.100 60.6 9.2 9.9 90.1 0.00 —
10.00 100.00
3/8" 9.520 93.7 14.2 24.2 75.8 Hit number
No. 4 4.760 136.7 20.7 44.9 55.1
No. 10 2.000 130.6 19.8 64.7 35.3
No. 20 0.840 84.7 12.8 77.5 22.5 Granulometric Distribution
No. 40 0.425 35.6 5.4 82.9 17.1
No. 60 0.250 20.5 3.1 86.0 14.0
No. 140 0.106 27.9 4.2 90.3 9.7 GG% 9.9
No. 200 0.075 5.7 0.9 91.1 8.9 % Gravel GF% 34.9 44.9
Moisture Content ASTM-D2216 (%) 1.4 AG% 19.8
% Sand A.M% 18.2
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 8.2 46.2
Plastic Index (IP) (%) - % Fine 8.9
Classification (SUCS ) : SP - SM
Classification (AASHTO): A-1-a
Group Index: 0
Group Name
Description (AASHTO): GOOD Poorly graded sand with silt and gravel

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-07 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 1.10-1.50

% % What's
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Mesh Retained % Accumulate happenin


Opening Weight Detained
CUMULATIVE PERCENTAGE PASSING (%)

(mm) d Withheld g
No.
3" 76.200 0.0 0.0 1.7 100.0
2" 50.800 8.0 1.7 1.7 98.3
1 1/2 " 38.100 12.0 2.6 4.3 95.7
1" 25.400 45.0 9.7 14.0 86.0
3/4" 19.100 45.0 9.7 23.6 76.4 0.00 —
10.00 100.00
3/8" 9.520 70.0 15.0 38.6 61.4 Hit number
No. 4 4.760 90.0 19.3 58.0 42.0
No. 10 2.000 71.0 15.2 73.2 26.8
No. 20 0.840 39.0 8.4 81.6 18.4 Granulometric Distribution
No. 40 0.425 14.0 3.0 84.6 15.4
No. 60 0.250 12.0 2.6 87.2 12.8
No. 140 0.106 13.0 2.8 90.0 10.0 GG% 23.6
No. 200 0.075 2.0 0.4 90.4 9.6 % Gravel GF% 34.3 58.0
ASTM-D2216 Moisture Content (%) 0.9 AG% 15.2
% Sand A.M% 11.4
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 5.8 32.4
Plastic Index (IP) (%) - % Fine 9.6
Classification (SUCS ) : GP - GM
Classification (AASHTO): A-1-a
Group Index: 0
Description (AASHTO): GOOD
Group Name: Poorly graded gravel with silt and sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-08 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.80-1.40

% %
Mesh
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Retained %
Opening Accumulate What's
Weight Detained
(mm) d Withheld happeni
No. ng
3" 76.200 0.0 0.0 1.7 100.0
ACCUMULATED PERCENTAGE
WHAT'S HAPPENING (%)

2" 50.800 8.0 1.7 1.7 98.3


1 1/2 " 38.100 12.0 2.6 4.3 95.7
1" 25.400 27.0 5.8 10.1 89.9
3/4" 19.100 45.0 9.7 19.8 80.2 0.00 —
10.00 100.00
3/8" 9.520 50.0 10.7 30.5 69.5 Hit number
No. 4 4.760 90.0 19.3 49.8 50.2
No. 10 2.000 71.0 15.2 65.0 35.0
No. 20 0.840 39.0 8.4 73.4 26.6 Granulometric Distribution
No. 40 0.425 14.0 3.0 76.4 23.6
No. 60 0.250 12.0 2.6 79.0 21.0
No. 140 0.106 13.0 2.8 81.8 18.2 GG% 19.8
No. 200 0.075 2.0 0.4 82.2 17.8 % Gravel GF% 30.1 49.8
ASTM-D2216 Moisture Content (%) 1.1 AG% 15.2
% Sand A.M% 11.4
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 5.8 32.4
Plastic Index (IP) (%) % Fine 17.8
Classification (SUCS ) : G.M.
Classification (AASHTO): A-1-b
Group Index: 0
Group Name:
Description (AASHTO): GOOD Silty gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-09 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.10-1.50

% %
Mesh
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Retained %
Opening Accumulate What's
Weight Detained
(mm) d Withheld happeni
No. ng
3" 76.200 0.0 0.0 1.3 100.0
ACCUMULATED PERCENTAGE
WHAT'S HAPPENING (%)

2" 50.800 6.0 1.3 1.3 98.7


1 1/2 " 38.100 14.0 3.0 4.3 95.7
1" 25.400 24.0 5.2 9.4 90.6
3/4" 19.100 40.0 8.6 18.0 82.0 0.00 —
10.00 100.00
3/8" 9.520 65.0 14.0 32.0 68.0 Hit number
No. 4 4.760 100.0 21.5 53.5 46.5
No. 10 2.000 67.0 14.4 67.8 32.2
No. 20 0.840 35.0 7.5 75.4 24.6 Granulometric Distribution
No. 40 0.425 14.0 3.0 78.4 21.6
No. 60 0.250 12.0 2.6 80.9 19.1
No. 140 0.106 13.0 2.8 83.7 16.3 GG% 18.0
No. 200 0.075 2.0 0.4 84.2 15.8 % Gravel GF% 35.4 53.5
ASTM-D2216 Moisture Content (%) 1.5 AG% 14.4
% Sand A.M% 10.5
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 5.8 30.7
Plastic Index (IP) (%) % Fine 15.8
Classification (SUCS ) : G.M.
Classification (AASHTO): A-1-a
Group Index: 0
Group Name:
Description (AASHTO): GOOD Silty gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-10 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.40-1.50
Mesh
Weight % % That
No. Opening Detained Detained Accumulate Happ
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

3" 76.200 0.0 0.0 0.0 100.0


WHAT'S HAPPENING (%)

2" 50.800 0.0 0.0 0.0 100.0


PERCENTAGE

1 1/2 " 38.100 288.6 17.8 17.8 82.2


1" 25.400 473.0 29.2 47.0 53.0
3/4" 19.100 131.9 8.1 55.2 44.8 0.00 —
10.00 100.00
3/8" 9.520 183.4 11.3 66.5 33.5 Hit number
No. 4 4.760 97.9 6.0 72.5 27.5
No. 10 2.000 86.7 5.4 77.9 22.1
No. 20 0.840 64.3 4.0 81.8 18.2 Granulometric Distribution
No. 40 0.425 65.5 4.0 85.9 14.1
No. 60 0.250 96.1 5.9 91.8 8.2
No. 140 0.106 55.8 3.4 95.3 4.7 GG% 55.2
No. 200 0.075 15.9 1.0 96.2 3.8 % Gravel GF% 17.4 72.5
Moisture Content ASTM-D2216 (%) 0.9 AG% 5.4
% Sand A.M% 8.0
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 10.4 23.7
Plastic Index (IP) (%) - % Fine 3.8
Classification (SUCS ) : GP
Classification (AASHTO): A-1-a
Group Index: 0
Group Name
Description (AASHTO): GOOD Poorly graded gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-11 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 1.00-1.50

% % What's
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Mesh Retained % Accumulate happenin


Opening Weight Detained
CUMULATIVE PERCENTAGE PASSING (%)

(mm) d Withheld g
No.
3" 76.200 0.0 0.0 5.2 100.0
2" 50.800 70.0 5.2 5.2 94.8
1 1/2 " 38.100 85.3 6.4 11.6 88.4
1" 25.400 234.6 17.6 29.2 70.8
3/4" 19.100 181.8 13.6 42.8 57.2 0.00 —
10.00 100.00
3/8" 9.520 132.8 9.9 52.7 47.3 Hit number
No. 4 4.760 161.9 12.1 64.8 35.2
No. 10 2.000 91.9 6.9 71.7 28.3
No. 20 0.840 88.6 6.6 78.3 21.7 Granulometric Distribution
No. 40 0.425 68.3 5.1 83.4 16.6
No. 60 0.250 37.9 2.8 86.3 13.7
No. 140 0.106 14.9 1.1 87.4 12.6 GG% 42.8
No. 200 0.075 8.3 0.6 88.0 12.0 % Gravel GF% 22.1 64.8
ASTM-D2216 Moisture Content (%) 1.0 AG% 6.9
% Sand A.M% 11.7
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 4.6 23.2
Plastic Index (IP) (%) - % Fine 12.0
Classification (SUCS ) : GP - GM
Classification (AASHTO): A-1-a
Group Index: 0
Description (AASHTO): GOOD
Group Name: Poorly graded gravel with silt and sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-12 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.20-1.50

% %
Mesh
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Retained %
Opening Accumulate What's
Weight Detained
(mm) d Withheld happeni
No. ng
3" 76.200 0.0 0.0 0.0 100.0
ACCUMULATED PERCENTAGE
WHAT'S HAPPENING (%)

2" 50.800 0.0 0.0 0.0 100.0


1 1/2 " 38.100 204.7 14.0 14.0 86.0
1" 25.400 168.1 11.5 25.4 74.6
3/4" 19.100 168.0 11.5 36.9 63.1 0.00 —
10.00 100.00
3/8" 9.520 181.7 12.4 49.3 50.7 Hit number
No. 4 4.760 182.7 12.5 61.7 38.3
No. 10 2.000 185.0 12.6 74.4 25.6
No. 20 0.840 130.8 8.9 83.3 16.7 Granulometric Distribution
No. 40 0.425 94.0 6.4 89.7 10.3
No. 60 0.250 45.7 3.1 92.8 7.2
No. 140 0.106 60.4 4.1 96.9 3.1 GG% 36.9
No. 200 0.075 16.3 1.1 98.1 1.9 % Gravel GF% 24.9 61.7
ASTM-D2216 Moisture Content (%) 0.8 AG% 12.6
% Sand A.M% 15.3
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 8.4 36.3
Plastic Index (IP) (%) % Fine 1.9
Classification (SUCS ) : G.W.
Classification (AASHTO): A-1-a
Group Index: 0
Group Name:
Description (AASHTO): GOOD Well graded gravel with sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-13
FLUIDITY DIAGRAM
Sample M-01

Depth (m) 0.10-0.50

% %
Mesh Retained % Accumulate What's
Opening Weight Detained
d Withheld happeni
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

No. ng
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.0 100.0


2" 50.800 0.0 0.0 0.0 100.0
PERCENTAGE

1 1/2 " 38.100 0.0 0.0 0.0 100.0


1" 25.400 4.0 1.2 1.2 98.8
3/4" 19.100 5.0 1.6 2.8 97.2 0.00 —
10.00 100.00
3/8" 9.520 22.4 7.0 9.8 90.2 Hit number
No. 4 4.760 24.8 7.7 17.5 82.5
No. 10 2.000 39.7 12.4 29.8 70.2
No. 20 0.840 23.0 7.2 37.0 63.0 Granulometric Distribution
No. 40 0.425 25.0 7.8 44.8 55.2
No. 60 0.250 19.8 6.2 51.0 49.0
No. 140 0.106 17.0 5.3 56.3 43.7 GG% 2.8
No. 200 0.075 2.1 0.6 56.9 43.1 % Gravel GF% 14.7 17.5
ASTM-D2216 Moisture Content (%) 5.5 AG% 12.4
% Sand A.M% 14.9
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 12.1 39.4
Plastic Index (IP) (%) - % Fine 43.1
Classification (SUCS ) : YE
Classification (AASHTO): A-4
Group Index: 2
Group Name
Description (AASHTO): REG-BAD Silty sand with gravel

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-14 FLUIDITY DIAGRAM

Sample M-01
Depth (m) 0.20-1.50

% % What's
GRANULOMETRIC ANALYSIS BY SIEVING ASTM-D422

Mesh Retained % Accumulate happenin


Opening Weight Detained
CUMULATIVE PERCENTAGE PASSING (%)

(mm) d Withheld g
No.
3" 76.200 0.0 0.0 0.0 100.0
2" 50.800 0.0 0.0 0.0 100.0
1 1/2 " 38.100 264.7 18.1 18.1 81.9
1" 25.400 168.1 11.5 29.5 70.5
3/4" 19.100 108.0 7.4 36.9 63.1 0.00 —
10.00 100.00
3/8" 9.520 171.7 11.7 48.6 51.4 Hit number
No. 4 4.760 282.7 19.3 67.9 32.1
No. 10 2.000 185.0 12.6 80.5 19.5
No. 20 0.840 30.8 2.1 82.6 17.4 Granulometric Distribution
No. 40 0.425 74.0 5.0 87.7 12.3
No. 60 0.250 45.7 3.1 90.8 9.2
No. 140 0.106 45.4 3.1 93.9 6.1 GG% 36.9
No. 200 0.075 6.3 0.4 94.3 5.7 % Gravel GF% 31.0 67.9
ASTM-D2216 Moisture Content (%) 1.2 AG% 12.6
% Sand A.M% 7.1
Liquid Limit (LL) ASTM-D4318 (%)
Plastic Limit (LP) ASTM-D4318 (%) NP AF% 6.6 26.4
Plastic Index (IP) (%) - % Fine 5.7
Classification (SUCS ) : GP - GM
Classification (AASHTO): A-1-a
Group Index: 0
Description (AASHTO): GOOD
Group Name: Poorly graded gravel with silt and sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Q
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO SOIL MECHANICS LABORATORY

STANDARD CLASSIFICATION TESTS


(ASTM D422 - D2216 - D4318 - D2487)

APPLICANT PROJECT PROMOTION INMOBILIARIA DEL SUR SA


LOCATION DATE SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 MACRÓPOLIS, DISTRICT OF LURÍN
JULY 3, 2018

Calicata C-15 FLUIDITY DIAGRAM

Sample M-01 40.00

Depth (m) 0.50-1.10

% %
Mesh Retained % What's
Opening do Accumulate
Weight Retain
No. d Withheld happenin
SIEVING ASTM-D422 ACCUMULATED

(mm)
GRANULOMETRIC ANALYSIS BY

g 20.00
WHAT'S HAPPENING (%)

3" 76.200 0.0 0.0 0.0 100.0


2" 50.800 0.0 0.0 0.0 100.0
PERCENTAGE

1 1/2 " 38.100 0.0 0.0 0.0 100.0


1" 25.400 0.0 0.0 0.0 100.0
3/4" 19.100 0.0 0.0 0.0 100.0 0.00 - - - -
10.00 100.00
3/8" 9.520 22.4 7.0 7.0 93.0 Hit number
No. 4 4.760 24.8 7.7 14.7 85.3
No. 10 2.000 39.7 12.4 27.0 73.0
No. 20 0.840 33.0 10.3 37.3 62.7 Granulometric Distribution
No. 40 0.425 44.1 13.7 51.1 48.9
No. 60 0.250 19.8 6.2 57.2 42.8
No. 140 0.106 15.9 4.9 62.2 37.8 GG% 0.0
No. 200 0.075 2.1 0.6 62.8 37.2 % Gravel GF% 14.7 14.7
Moisture Content ASTM-D2216 (%) 6.3 AG% 12.4
% Sand A.M% 24.0
Liquid Limit (LL) ASTM-D4318 (%) 23
Plastic Limit (LP) ASTM-D4318 (%) 18 AF% 11.8 48.1
Plastic Index (IP) (%) 5 % Fine 37.2
Classification (SUCS ) : SC-SM
Classification (AASHTO): A-4
Group Index: 0
Group Name
Description (AASHTO): REG-BAD Clayey silt sand

Observations:

Done Technician Angel Reyes


reviewed Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
EITH Consultants in Engineering and Supervision in Construction Soil Mechanics

ER
Laboratory

CINSUC P ODIFIED ESSAY


O (ASTM-D1557-C)

PROJECT : PROMOCION INMOBILIARIA DEL SUR SA


APPLICANT : SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017


Calicata : C-01
Sample : M-1
Depth (m) : 0.40-1.50
Classification (SUCS) : G.M.

DATA TABLE
Humidity (%) 2.75 6.50 8.50 11.50
Dry Density ( (g/cm )
3
2.01 2.17 2.20 2.02
ys)
RESULTS
M. d. S. = 2.20 Kg/cm 3

EITHER. c. H. = 8.2 %

Moisture content (%)

Done : Technician Samuel Saldarriaga : Eng. Julio Soto


Reviewed

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision

EIT
Soil Mechanics Laboratory

HER
COMPACTION CINSUCO CALIFORNIA SUPPORT RATIO (CBR) ESSAY
Mold I
(ASTM-D1883)
Mold II Mold III
Number of layers 5 5 5
Strikes per layer 13 27 56
Initial humidity (%) 7.90 8.50 9.20
APPLICANT : PROMOCION INMOBILIARIA DEL SUR SA
Final humidity (%) 8.70 9.50 9.98
PROJECT
dry density (g/cm:3 SOIL
) STUDIES FOR PAVEMENT
2.02 PURPOSES MACROPOLIS PROJECT
2.15– SUB LOT 41 2.22

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017

Calicata : C-01 preliminary test modified proctor


Sample : M-1 ASTM Standard D1557-C
Depth (m) : 0.40-1.50 M. d. S. (g/cm 3 ) 2.20
Classification (SUCS) : G.M. EITHER. c. H. (%) 8.2 %

PRESSURE (lb/in²)
PENETRATION
mm in. Mold I Mold II Mold III
0.00 0.000 0.00 0.00 0.00
0.64 0.025 47.00 58.00 74.00
1.27 0.050 86.00 105.00 144.00
1.91 0.075 134.00 180.00 243.00
2.54 0.100 199.00 284.00 381.00
3.81 0.150 264.00 378.00 526.00
5.08 0.200 358.00 492.00 717.00
6.35 0.250 455.00 605.00 891.00
7.62 0.300 567.00 756.00 1089.00
10.16 0.400 1063.00 1406.00 2061.00
12.70 0.500 1465.00 1933.00 2890.00
CORRECTED PRESSURE Mold I Mold II Mold III

Penetration (in) 0.1 0.2 0.1 0.2 0.1 0.2


Pressure (lb/in²) 199.0 358.0 284.0 492.0 381.0 717.0

CBR (%) 39.80 47.73 56.80 65.60 76.20 95.60

EXPANSION %
TIME hours Mold I Mold II Mold III

40 - - -

Coach Samuel Saldarriaga


Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -

Done

reviewed
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING V GEOTECHNICS

CALIFORNIA SUPPORT RATIO (CBR) ESSAY


(ASTM-D1883)
APPLICANT: PROMOCION INMOBILIARIA DEL SUR SA Calicata : C-01
PROJECT: SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 Sample : M-1
Depth (m) : 0.40-1.50
LOCATION: MACRÓPOLIS, LURÍN DISTRICT : G.M.
Classification (SUCS)
Preliminary test : Modified Proctor
DATE : JULY 3, 2017
Made: Technician Samuel Saldarriaga
PENETRATION CURVE

Penetration (in.)

Reviewed: Eng. Julio Soto

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision

EITH
Soil Mechanics Laboratory

ER
CINSUC MODIFIED PROCTOR TEST
O (ASTM-D1557-C)

PROJECT : PROMOCION INMOBILIARIA DEL SUR SA


APPLICANT : SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017


Calicata : C-09
Sample : M-1
Depth (m) : 0.10 - 1.50
Classification (SUCS) : G.M.

DATA TABLE
Humidity (%) 4.90 6.50 9.70 12.60
Dry Density ( (g/cm )
3
2.05 2.17 2.22 2.10
ys)
RESULTS
M. d. S. = 2.23 Kg/ cm 3

EITHER. c. H. = 8.9 %

COMPACTION CURVE

Done : Technician Samuel Saldarriaga : Eng. Julio Soto


Reviewed

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
c
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
CALIFORNIA SUPPORT RATIO (CBR) ESSAY
(ASTM-D1883)

PROJECT APPLICANT : PROMOCION INMOBILIARIA DEL SUR SA


: SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017


Calicata : C-09 preliminary test : Modified Proctor
Sample : M-1 ASTM Standard : D1557 - C

Depth (m) : 0.10 - 1.50 M. d. S. (g/cm 3 ) 2.233

Classification (SUCS) : G.M. EITHER. c. H. (%) : 8.9 %

COMPACTION Mold I Mold II Mold III


Number of layers 5 5 5
Strikes per layer 13 27 56
Initial humidity (%) 8.82 8.75 8.80
Final humidity (%) 9.50 9.10 10.20
dry density (g/cm 3 ) 2.09 2.15 2.24

PRESSURE (lb/in²)
PENETRATION
mm in. Mold I Mold II Mold III
0.00 0.000 0.00 0.00 0.00
0.64 0.025 81.74 88.03 111.61
1.27 0.050 196.50 201.22 232.66
1.91 0.075 326.98 342.70 503.04
2.54 0.100 503.04 589.50 834.73
3.81 0.150 723.12 833.16 1245.02
5.08 0.200 916.48 1155.42 1674.18
6.35 0.250 1039.09 1542.13 2027.88
7.62 0.300 1246.60 1891.12 2331.28
10.16 0.400 1540.56 2458.61 2813.88
12.70 0.500 1902.12 2829.60 3505.56
CORRECTED PRESSURE Mold I Mold II Mold III

Penetration (in) 0.1 0.2 0.1 0.2 0.1 0.2


Pressure (lb/in²) 503.0 916.5 589.5 1155.4 834.7 1674.2

CBR (%) 50.30 61.10 58.95 77.03 83.47 111.61

EXPANSION %
TIME hours Mold I Mold II Mold III

40 - - -

Done Coach Samuel Saldarriaga


Eng. Julio Soto
reviewed

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
EITHER
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

CALIFORNIA SUPPORT RATIO (CBR) ESSAY


(ASTM-D1883)
APPLICANT: PROMOCION INMOBILIARIA DEL SUR SA Calicata: C-09
PROJECT : SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41 Sample Depth (m) : M-1
Classification (SUCS) : 0.10 - 1.50
LOCATION : MACRÓPOLIS, LURÍN DISTRICT Preliminary test : G.M.
: Modified Proctor
DATE : JULY 3, 2017

PENETRATION CURVE

Penetration (in.)

Made: Technician Samuel Saldarriaga


Reviewed: Eng. Julio Soto
- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
MODIFIED PROCTOR TEST
(ASTM-D1557-B)

PROJECT : PROMOCION INMOBILIARIA DEL SUR SA


APPLICANT : SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017


Calicata : C-13
Sample : M-1
Depth (m) : 0.10 - 0.50
Classification (SUCS) : YE

DATA TABLE
Humidity (%) 6.70 8.90 10.60 12.50
Dry Density ( (g/cm )
3
1.80 1.91 2.02 1.92
ys)
RESULTS
M. d. S. = 2.03 Kg/ cm 3

EITHER. c. H. = 11.1 %

COMPACTION CURVE

Done : Technician Samuel Saldarriaga : Eng. Julio Soto


Reviewed

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision

EIT
Soil Mechanics Laboratory

HER
CINSUCO CALIFORNIA SUPPORT RATIO (CBR) ESSAY
(ASTM-D1883)

PROJECT APPLICANT : PROMOCION INMOBILIARIA DEL SUR SA


: SOIL STUDIES FOR PAVEMENT PURPOSES MACROPOLIS PROJECT – SUB LOT 41

LOCATION : MACRÓPOLIS, LURÍN DISTRICT

DATE : JULY 3, 2017


Calicata : C-13 preliminary test : Modified Proctor
Sample : M-1 ASTM Standard : D1557 - B

Depth (m) : 0.10 - 0.50 M. d. S. (g/cm 3 ) 2.03

Classification (SUCS) : YE EITHER. c. H. (%) : 11.1 %

COMPACTION Mold I Mold II Mold III


Number of layers 5 5 5
Strikes per layer 13 27 56
Initial humidity (%) 10.80 10.98 11.40
Final humidity (%) 13.19 12.78 13.20
dry density (g/cm 3 ) 1.82 1.94 2.05

PRESSURE (lb/in²)
PENETRATION
mm in. Mold I Mold II Mold III
0.00 0.000 0.00 0.00 0.00
0.64 0.025 62.88 69.17 73.88
1.27 0.050 111.61 155.63 161.29
1.91 0.075 204.36 240.52 281.39
2.54 0.100 286.10 325.40 413.44
3.81 0.150 424.44 498.32 686.96
5.08 0.200 558.06 694.82 954.20
6.35 0.250 701.11 907.04 1246.60
7.62 0.300 830.02 1057.96 1487.11
10.16 0.400 988.79 1397.51 1839.24
12.70 0.500 1224.59 1760.64 2225.95
CORRECTED PRESSURE Mold I Mold II Mold III

Penetration (in) 0.1 0.2 0.1 0.2 0.1 0.2


Pressure (lb/in²) 286.1 558.1 325.4 694.8 413.4 954.2

CBR (%) 28.61 37.20 32.54 46.32 41.34 63.61

EXPANSION %
TIME hours Mold I Mold II Mold III

40 - - -

Done Coach Samuel Saldarriaga


Eng. Julio Soto
reviewed

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

CALIFORNIA SUPPORT RATIO (CBR) ESSAY


(ASTM-D1883)
SAC Engineers
149 Valladolid Street
APPLICANT : PROMOCION INMOBILIARIA DEL SUR SA Calicata : C-13
Urb. Mayorazgo II Stage, Ate
PROJECT Lima :Peru
SOIL STUDIES FOR PAVEMENT
. PURPOSES MACROPOLIS PROJECT – SUB LOT 41 Sample : M-1
Telephone: 348-9494 / 348-6919
E-mail:!
Depth (m) : 0.10 - 0.50
LOCATION : MACRÓPOLIS, LURÍN DISTRICT Classification (SUCS) : YE
nformes@jb FILE N' 188-2015-JBO preliminary test : Modified Proctor
:
DATE
oingenieros. ESSAY REPORT
JULY 3, 2017
APPLICANT ADDRESS Inversiones Centenario SAA
PROJECT Urban Enabling PRINSUR -
Done REFERENCE DATE
Reviewed
RECEIVED com PENETRATION CURVE Av. Victor A. Belaunde 147, San Isidro

Service Request No. 188-2015-JBO May LOCATION


LURIN

Lurin
20, 2015 START DATE May 20, 2015
STANDARDIZED TEST METHOD FOR THE ANALYSIS OF PARTICLE SIZE OF SOILS

SAMPLE REFERENCES
ASTM D422

ID CCC-8 / M-1 (Depth: 0.20 - 2.10m) PRESENTATION 01 Polypropylene bags.


AMOUNT 80 kg approx.

SOIL CHARACTERIZATION
TIGHTS PARTIAL ACCUMULAT
(ASTM 0 4318-10e1)
AMERICAN OPENING (mm) ' HELD ED WITHOLD liquid limit , (%) Yo 'NP
:
SERIES
(%L HAPPENS ' (%) or LA CAI IDAD EN INC
Plastic limit IN IN ' (%)
MIL Fi , J i /■ U 5 V
(ASTM D 4318-10e1) NP
3" 75.000 *
62.500
QUALITY 1 ti IC :
21/2"
• F ' ■ ; L' . , 1 (ASTM 0 4318-10e1)
2' 50.000 100 plastic index (%) : H.P.
11/2- 37.500 10 10 90 , 1 DAD IN ENGINEERING Yo • SE URAI
SUCS1 Classification (ASTM 0 2487-11) : GP
1- 25.000 ________ 26 74 LI ITY IN ENGINEERING . I 5 ( ASELR - ' i N í OOI
W 19.000 9 35 65
1/2' 12.500 12 47 53
Claslf. for IDADENI use on transport (ASTM D 3282-09) : A-1-a(0)
routes 1: Gl '
3/8' 9.500 9 56 44
1/4" 6.250 8 64 . 36 Cont. moisture (ASTM D
N*4 4.750 5 69 31 2216-10)
N6 3.350 4 1 73 27
N*8 2.360 4 Penetration
77 (in.) 23 Sample Description: Poorly graded gravel with sand
N-10
: Technician
2.000
Samuel
2
Saldarriaga
79
: Eng.
21
Julio Soto
N-16 1.180 , 4,, 83 17
1A 230
OBSERVATIONS:
N- 20 0.850 85 15
Sample taken and identified by the applicant
N*30 0.600 2 87 13
N- 40 0.425 2 89 11 FROM QUALITY IN JÜO ASE ENGINEERING QUALITY IN JBO
No. 50 0.300 2 91 9 ASECURAMI ENGINEERING____JBO ASE ENGINEERING
N- 80 0.177 2 you 93 i ,7 ■ .
N-100 0.150 - Calle
1 4, Lot9433 Block M
6 Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
N* 0.075 2 96 4
-200 ASTM 01140:00 4 100
GRANULOMETRIC CURVE J BO A SEC VIRA
N ' • ' - . JBO INSURES
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

SAC Engineers
149 Valladolid Street
Urb. Mayorazgo II Stage, Ate
Lima Peru
Telephone: 348-9494 / 348-6919
E-mallzinformes@jboingenleros.com

FILE N° 188-2015-JBO

ESSAY REPORT
APPLICANT ADDRESS Inversiones Centenario SA A. PRINSUR LURIN Urban Enabling
PROJECT
REFERENCE Av. Victor A. Belaunde 147, San isidro
RECEPTION DATE Service Request N® 188-2015-JBO LOCATION Lur
May 20, 2015 in20, 2015
START DATE May

DETERMINATION OF THE LIQUID LIMIT,


PLASTIC LIMIT and PLASTICITY INDEX IN SOILS
ASTM D4318 - 10e1
SAMPLE REFERENCES
IDENTIFICATIO CCC-8/M-1 (Depth: 0 20 - 2 10m) PRESENTATION 01 Polypropylene bags
N DESCRIPTION Poorly graded gravel with sand AMOUNT 80 kg approx.

DESCRIPTION LIMIT LIQUID PLASTIC LIMIT

Test N" 1 2 3 4 1 2
Capsule N' ----------4

Capsule weight + moist soil (g) =treet •

Capsule weight + dry soil (g) As z____________ 1


Water Weight (g) -- --

Capsule weight (g) ■

dry soil weight (g)


Moisture content (%) -- -> -•

Number of strokes t-

FLUIDITY DIAGRAM

TEST RESULTS

LIQUID LIMIT

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
PLASTIC LIMIT (%)

IND PLASTICITY (%)


Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
Consultants in Engineering and Construction Supervision
Soil Mechanics Laboratory

CINSUCO
ENGINEERING AND GEOTECHNICS

- Calle 4, Lot 33 Block M Urbanization La Alameda del Pinar, Comas / Tel.961751161 – 995190267 -
SAC Engineers

130
Callo Valladolid 149
Urb. Mayorazgo II Stage, Ate
SAC Engineers
Lima Peru
149 Valladolid Street
Phone. 348-0494 / 348-6919
Urb. Mayorazgo II Stage, Are
E-mailtinformes@jboingenieros.com
Lima Peru
Telephone: 348-6494 I 348-8919
E-mallainformes@jboingenieros com
000157
| FILE N° 188-2015-JBO |

FILE N® 188-201 5-JBO

ESSAY REPORT
ESSAY REPORT

APPLICANT APPLICANT : Inversiones Centenario SAA Centenario SAA.


: Inversiones PROJECT : Urban
PROJECT Enabling PRINSUR ■ LURIN
: Urban Enabling PRINSUR - LURIN
ADDRESS
ADDRESS : Av. Victor A. Belaunde
: Av.147,
VictorSan Isidro 147, San lsdr 0
A Belaunde
REFERENCEREFERENCE : Service Request No. 188-2015-JBO
: Service Request N* 188-2015-J80
LOCATION : Lurin
LOCATION . Lurin
RECEPTION RECEPTION
DATE DATE: May 20, 2015
. May 20, 2015 START DATE: May
Start20,
date2015 May 20, 2015
STANDARDIZED TEST METHOD FOR THE ANALYSIS OF THE PARTICLE SIZE OF SOILS

TEST METHOD TO DETERMINE THE MOISTURE CONTENT OF A SOIL


ASTM D422
SAMPLE REFERENCES
ID ASTMD2216
CCC-9/M-1(Depth 10.20- PRESENTATION : 01 Polypropylene bags. : 80 kg
2.20m) AMOUNT
SAMPLE REFERENCES approx

SOIL CHARACTERIZATION
ID ; CCC-8 / M-1 (Depth:
_________GRANULOMETRIC 0 20 • 2.10m) OF SOILS
ANALYSIS PRESENTATION: 01 Polypropylene bags.
DESCRIPTION PARTIAL
: Poorly graded gravel with sand ACCUMULAT AMOUNT : 80 kg approx. (ASTM D 431 B-10e1)
MESH S SERIES OPENING HELD ED liquid limit (%) NP
HAPPENS (%)
:
'AMERICAN__________________ (mm) L (%) WITHHOLD J
(ASTM D 431 8-10e1)
3 75.000 %) plastic limit () NP

21/2- 62.500 ID MOISTURE CONTENT (%) :


(ASTM D 431 8-10e1)
2- 50.000 100 plastic index (%) NP
:
11/2 37.500 8 8 92
SUCS Classification (ASTM D 2467-11) : GP
1 25.000 24 32 68
CCC-8/M-1 (Depth: 0.20 - 2.10m) 11.9
3/4’ 19.000 11 43 57
Classification for use
1/2- 12 500 13 56 44 (ASTM D 3282-09) ; A-1-a(0)
on transport routes
3/8” 9.500 6 62 38
OBSERVATIONS : 14 6.250 6 68 32 Humidity count (%) (ASTM D 2216-10)
N'4- Sample taken4.750 3 applicant
and identified by the 71 29
N'6 3.350 2 73 27
Reference: AND. . .
N8 2 360 ' 3 76 24 Equipment
Sample Description: Poorly graded used:
gravel with sand

I
ASTM D No. 10
2216-10 2.000
Standard test 2
methods for 78
laboratory 22
determination of waler (moisture) content of soil and rock by mass - BAL-09 JLM-00040315
(03-20-15)
N'16 1.180 4 82 18
OBSERVATIONS:
N'20 0.850 2 84 16
- Sample taken and identified by the JLT-00040315 (03-20-15)
- HOR-02
N'30 0.600 3 87 13 applicant

I
N* 0.425 3 90 10
N'50 0.300 2 92 8
Staff:
N80 0.177 2 94 6 -Tech: EE.A.
N' 100 0150 1 95 5 - Rev.: MMF

I
N'200 0075 1 96 4
■200 ASTM 0 1140:00 4 100 -•1
Issue date : Lima, May CURVE
GRANULOMETRIC 26, 2015
The use of the information contained in this document is the responsibility of the applicant.

I (TO 1—/
JUAN SERGIO SANCHEZ GUANDO
CIVIL ENGINEER
Reg. CIP. No. 59781

Y 70

60

MESH OPENING (mm)

Equipment used:
Reference:
ASTM D 422- Standard test method for particle-size analysis of soils
63 - BAL-03 JLM-00160315
plasticity index sols
Standard test method far Equid mitpiastic imitation and of
ASTM D4318-10e1 standard test methods tor laboratory determanaton of water (moisture) contení 1 sol and HOR-02JLT-
ASTM D 2216- rock ty mass
10
standad practcs for ctassifcakon d sols- JUA
ASTM D 2487-
11 aggregate matses for hg"wa! with N
INGENSRSEMGUANDO
ASTM D 3282-
09
srucdon Purposes Standard testtor amount d maten >1 o Staff: Reg. CIP. N® 59781
ASTM D 1140- sols ** than the N 200 (5 umm) seve -Tc:EEA
Lima Issue Date. May 26, 2015 -Rev.:MM.F.
00
The use of the Intomacon contained in document *' of exeusiva
responsabiidadoel solctants

Scanned by
131
SAC Engineers
149 Valladolid Street
Urb. Mayorazgo II Stage, Ate
_ ma Peru
Telephone: 348-0494 / 348-6919
E-mail
iniormes@jboingenieros.com

FILE N° 188-2015-JBO

ESSAY REPORT
APPLICANT Inversiones Centenario SAA PROJECT Urban Enabling PRINSUR - LURIN
ADDRESS Av. Victor A Belaunde 147, San Isidro
REFERENCE Service Request No. 188-2015-JBO LOCATION Lurin
RECEPTION DATE May 20, 2015
START DATE May 20, 2015

TEST METHOD TO DETERMINE THE MOISTURE CONTENT OF A SOIL

ASTM D2216

SAMPLE REFERENCES

ID CCC-9/M-1 (Depth: 0.20 - 2.20m) PRESENTATION: 01 Polypropylene bags.

DESCRIPTION Poorly graded gravel with sand 80 kg


AMOUNT
approx.

MOISTURE CONTENT (%)


ID

CCC-9/M-1 (Depth: 0.20 - 2.20m) 2.3

OBSERVATIONS
Sample taken and identified by the applicant

Reference: Equipment used:


Standard test methods for laboratory determination of water (moisture) content of soil and rock by mass - BAL-09 JLM-00040315 (03-20-15)
ASTM. D 2216-10
- H0R-O2 JLT-00040315 (03-20-15)

Staff:
- Tech.: EEA
- Rev.: MMF

Issue date : Lima, May 26 , 2015


The use of the information contained in this document is the responsibility of the applicant.

JUAN SERGIO SANCHEZ GUANDO


CIVIL ENGINEER Reg. CIP. No.
59781

Scanned by
132

Scanned by
33 SAC Engineers
149 Valladolid Street
Urb Mayorazgo II Stage. tie
Lime. Peru
Telephone: 348-9494 / 348-6919

0
E-mall:informes@jboingenieros com

FILE N° 188-2015-JBO

Yo ESSAY REPORT
Urban Room PRINSUR - LURN
: Inversiones Centenario SA A. PROJECT
( APPLICANT ADDRESS REFERENCE : Av. Victor A. Belaunde 147, San Isidro
: Service Request NP 188-2015-JBO LOCATION : Lurin
DATE OF RE
: May 20, 2015 : May 20, 2015

Yo
AND PLASTICITY
DETERMINATION OF THE LIQUID LIMIT, PLASTIC LIMIT

INDEX IN SOILS
ASTM D4318-10e1

TEST RESULTS

LIQUID LIMIT (%) NP

PLASTIC LIMIT (%) NP

PLASTICITY INDEX (%) NP

OBSERVATIONS :___________
- Test carried out on material passing through mesh No. 40.
- The sample slides into the Casagrande glass.
- The Liquid Limit cannot be determined.
- Could not form 1/8' diameter rolls , crumbles.
- The plastic limit cannot be determined.
- Sample taken and identified by the applicant.

Reference: Equipment used:


ASTM D4318 -10e1 Standard test methods for liquid limit, plastic limit and plasticity index of - BAL-03 JLM-00160315 (03-20-
soils 15)
- HOR-02 JLT-00040315 (20.43-15)

Staff:
- Tech.: EEA
- Rev. M UBAN SERGIO SANCHSZ GUANDO
Issue date: Lima, May 26, 2015 CIVIL ENGINEER
The use of the information contained in this document is the responsibility of the Reg. CIP. No.
applicant. 59781

SAMPLE REFERENCES
Yo ID : CCC-9/M-1 (Depth: 0.20- 2.20m) PRESENTATION : 01 Bags of polyproptene.

Yo DESCRIPTION : Poorly graded gravel with sand AMOUNT í 80" approx.

Yo
Yo

Scanned by
33
Yo
1
Yo
Yo
F 00002.9
•’ . "ki e. rzouenekia O AsdtiRfin

Scanned by
ANNEX D: PHOTOGRAPHIC RECORD
Annex D, Photographic Record May 2019

Photo N° 01: Panoramic view of pit C-1

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -1-


Annex D, Photographic Record May 2019

Photo N° 02: Panoramic view of pit C-2.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -2-


Annex D, Photographic Record May 2019

Photo N° 03: Panoramic view of pit C-3

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -3-


Annex D, Photographic Record May 2019

Photo N° 04: Panoramic view of pit C-4.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -4-


Annex D, Photographic Record May 2019

Photo N° 05: Panoramic view of pit C-5.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -5-


Annex D, Photographic Record May 2019

Photo N° 06: Panoramic view of pit C-6.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -6-


Annex D, Photographic Record May 2019

Photo N° 07: Panoramic view of pit C-7

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -7-


Annex D, Photographic Record May 2019

Photo N° 08: Panoramic view of pit C-8.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -8-


Annex D, Photographic Record May 2019

Photo N° 09: Panoramic view of pit C-9

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -9-


Annex D, Photographic Record May 2019

Photo N° 10: Panoramic view of pit C-10.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -10-


Annex D, Photographic Record May 2019

Photo N° 11: Panoramic view of pit C-11.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -11-


Annex D, Photographic Record May 2019

Photo N° 12: Panoramic view of pit C-12.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -12-


Annex D, Photographic Record May 2019

Photo N° 13: Panoramic view of pit C-13

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -13-


Annex D, Photographic Record May 2019

Photo N° 14: Panoramic view of pit C-14.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -14-


Annex D, Photographic Record May 2019

Photo N° 15: Panoramic view of pit C-15

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -15-


Annex D, Photographic Record May 2019

Photo N° 16: Panoramic view of the CCC-8 pit

Photo N° 17: Panoramic view of the CCC-9 pit.

Soil Studies for Paving Purposes Macrópolis Project Stage 2 -16-

You might also like