32 01 ReviewComments

You might also like

Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 1

UG-TIL-00-M044-100332 - GENERAL: BUILDINGS - PLUMBING SYSTEM - TYPICAL DETAIL Click here to view review comments in New Prodom (login

s in New Prodom (login required)


Revision: 01 (IFR)
Approver: Daher, Nicolas
Finalized: 20-Feb-2024 (UTC +0)
Review Status: 2 - Accepted with comments

Comment ID Comment Response Status File Name Page Number


1833189 Please show floor drain plan view Plan view is shown on plumbing layouts. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1833192 Details are not legible. Also, please provide dimensions. Provided Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1833195 Any waterproofing membrane? Shown in drawing Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1833198 Please add pipe support support added Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1833205 Is it top entry connection? If not, please show the connection of how the DCW It is top entry connection. Vendor still need to confirm separate Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
supply pipe is connected to the WC flusher. Where is the isolation valve? isolation valve or cistern mounted isolation valve to be fitted.

1833215 Pipe size? As per approved manufacturer details UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1


1844038 There are two different legend sheets from Plumbing and Architecture. Are they changed. Only plumbing abbreviations included only. Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
the same. If not please amend.
1844060 Material is not according to Uganda the national building code, 2019. Please As per National Building Code 2019, the material can be cast Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
amend. iron,steel , copper or other approved material. Based on this
expression, sanitary sewage pipe material will be PVC-U in
accordance with UG-TIL-00-MDT1-8000017
1844068 All pipe supports shall be designed for seismic conditions. Noted. UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844072 Please provide the following: 1.rainwater pipe connection details for roof gutters. Rain water pipe connection , electric water heater details are provided Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
2.detail for rainwater pipe discharging into gully. in Drawing No. UG-TIL-00-M044-100333. further details shall be
3.Grease trap detail. provided.
4.Electric water heater detail

1844130 Details are nto legible. Please amend. More information need to be included in details. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844188 Please check if this pipe size is according to Uganda The National Building Pipe sizes are as per national building standard. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
Code, 2019.
1844249 It should be automatic taps It is Automatic taps Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844260 Add support. added Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844333 Any cleaning eye provision? Not applicable for floor drain Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844340 These are not in line with penetration details above. Please align. These are only support details. Refer penetration detail separetly. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844364 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. The vent pipe is shown in plumbing layouts.

1844365 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. the vent pipe is shown in plumbing layouts.

1844366 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. the vent pipe is shown in plumbing layouts.

1844369 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1

1844370 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1

1844371 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1

1846477 P-Trap to be added here as well Urinal type shown in detail has got P-trap itself. No need a separate P- Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
trap.

You might also like