Professional Documents
Culture Documents
32 01 ReviewComments
32 01 ReviewComments
32 01 ReviewComments
1844130 Details are nto legible. Please amend. More information need to be included in details. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844188 Please check if this pipe size is according to Uganda The National Building Pipe sizes are as per national building standard. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
Code, 2019.
1844249 It should be automatic taps It is Automatic taps Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844260 Add support. added Implemented UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844333 Any cleaning eye provision? Not applicable for floor drain Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844340 These are not in line with penetration details above. Please align. These are only support details. Refer penetration detail separetly. Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844364 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. The vent pipe is shown in plumbing layouts.
1844365 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. the vent pipe is shown in plumbing layouts.
1844366 Any vent pipe to be shown? Since the air vent is common, not for each sanitary ware, it will not Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
shown in typical details. the vent pipe is shown in plumbing layouts.
1844369 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844370 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1844371 Plan view to be shown as well. Shown in Architecure drawing, plumbing layouts and sectional details Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
1846477 P-Trap to be added here as well Urinal type shown in detail has got P-trap itself. No need a separate P- Unchanged UG-TIL-00-M044-100332_01_IFR_20231208.PDF 1
trap.