Download as xlsx, pdf, or txt
Download as xlsx, pdf, or txt
You are on page 1of 28

Water and waste

Attchement of Document -GENE

PLUMBING
S.no Item code/Model
S20 U COUNTER
BASIN

FAU-01- ORIGIN TOUCHLESS


BAS. TAP. ELEC.

2
SOD-01,ORIGIN PHOTOCELL
CONTROLLED SOAP
DISPENSER

FLS-01,LOOP R CONTROL
PANEL

HDR-01, hand dryer

5
TOW-01,ARKITEKTA
PAPER DISPENSER

URI-01,PLURAL URINALTAUPE

WCL-01,S20 WALL-HUNG WC
PAN-WHITE

8
WSB-01,HYGIENE WASTE BIN

RFA-01, SIKA
MASTERTILE FLX 24- sealant

10

MES-01,SINK GALASSIA GAX


611 LHD

11
MES-01, PESCARA 360'
PROFESSIONAL SINK
MIXER

12

RFD-01,PARAPET DRAIN

13
Eye washer

14

FDA-01, floor drain

15
16 Pipes and fittings

17 Shower set with accessories

18 Pressure reducer

Note- Any other fixture, equipment ( If any) w


Note- Local ugandan code , inte
Note- Proper
Note - All fixtures , equipment shall b
Specification ref- UG-TIL-00-
Water and waste efficient Plumbing fixtures/sanitary fixture

Attchement of Document -GENERAL BUILDINGS - PLUMBING SYSTEM


For reference only

Description
3 MATERIALS
Materials shall comply in every respect with the standards listed. Any substitutions shall
be of equivalent quality and approved by CONTRACTOR and COMPANY..
3.1 Pipes
• Clean water pipe shall be either HDPE or PVC-U or Concrete with push-fit / flexible /
spigot / socket joint.
• Oily water pipe shall be Ductile Iron push-fit with Nitrile joint, GRP/GRE, HDPE or
Carbon Steel.
• Sanitary sewage pipe shall be PVC-U.
The above pipes shall also comply with the “Piping Materials Specification Class Index”
document no. UG-TIL-00-MDT1-700007.
3.2 Steel Pipes
• Steel pipes and specials shall comply with the requirements of EN 10224 and EN
10311.
3.3 Concrete Pipes and Fittings
• Both unreinforced and reinforced concrete pipes and fittings shall have flexible
spigot and socket joints and comply with BS 5911-1, BS 2494, EN 1916 and EN 681-1.
3.4 Unplasticised PVC Pipe
• Unplasticised PVC pipes and fittings shall have flexible spigot and socket joints with
rubber ring seals and comply with BS 4660, EN 1401-1 and EN 681-1.
3.5 GRP/GRE Pipe
• GRP/GRE pipes, fittings and joints shall comply with the requirements of EN 14364
and EN 1796.
3.6 High Density Polyethylene (HDPE) Pipes and Fittings
• HDPE pipes, valves and fittings shall comply with the requirements of EN 12201 and
EN 681-1.
3.7 Ductile Iron Pipes and Fittings
• Ductile iron pipes and fittings shall comply with EN 545, EN 598 and EN 969

Not yet selectected

Not yet selected

Note- Any other fixture, equipment ( If any) which is not mentioned above shall be selected as per a
Note- Local ugandan code , international standards and industry best practice shall be
Note- Proper Operating manuals and maintainance stretegy shall b
Note - All fixtures , equipment shall be installed in a standard way to avoid any any wasteg
Specification ref- UG-TIL-00-MDT1-800018- Architectural Specification for Building
efficient Plumbing fixtures/sanitary fixtures/valves/equipment/materials

RAL BUILDINGS - PLUMBING SYSTEM – BASIS OF DESIGN-UG-TIL-00-M044-100382


For reference only

Key
Detail Water conservation

Smooth waste water collection


with overflow for saveing
water spilage.

fitted with sensors and option


for the calibration of flow time.
Easy to control water usage as
required
Poratble, easy to fit, adicate
flow in each press, less waste.

2 step flush control for saving


water and to be operate as
required

No water used.
Proper collection and storage

Smooth waste water collection


with sensor. Water flow can be
control.

Smooth soil waste collection


with sensor. Flush water can be
control.
Proper collection and storage

water tight sealent for


avaoiding spillage and waste of
water.

Smooth waste water collection


with overflow for saveing
water spilage.
Moveble foucet set with air
seperator. Easy to operate and
control usage

Wide face area for rain water


collection.
fitted with water tank and
waste tank. Easy to operate
and to control usage as per
space requirement

Wide face area for rain water


collection.
Pipe selection for smooth flow
Specification for Drainage Materials and Construction-UG-TIL-00- less possibility of leakage, and
MDT1-800017 to withstand pressure. Less
friction losses.

selection shall be made as per


higher standard

selection shall be made as per


Specification for Drainage Materials and Construction-UG-TIL-00- higher standard with precise
MDT1-800017 control of flow and pressure
inside building

which is not mentioned above shall be selected as per acceptable standard and on the basis of higher water efficiency.
rnational standards and industry best practice shall be refer for designing and sizes of plumbing system
Operating manuals and maintainance stretegy shall be applies for efficient operation.
e installed in a standard way to avoid any any wastege and spillage of water and requires less maintainance.
MDT1-800018- Architectural Specification for Building Materials Para-5.12, UG-TIL-00-MDT1-800009
044-100382

Key measures
Efficiency Health and environment remark

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene

Proper protection Easy to clean and maintain


Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene

Highly effgicient with less Easy to clean and maintain


maintainance Hygiene
Highly effgicient with less Easy to clean and maintain
maintainance Hygiene . No water
contamination.

Shall be Highly effgicient Shall be Easy to clean and


with less maintainance maintain Hygiene

Shall be Highly effgicient Shall be Easy to clean and


with less maintainance maintain Hygiene

ater efficiency.
m

nance.

You might also like