Professional Documents
Culture Documents
PA18CAD04PAM1WS
PA18CAD04PAM1WS
Diffuse-reflective
Type PA18CAD04...WS, DC
• Miniature sensor range
• Range: 0.4 m
• Sensitivity adjustment by potentiometer
• Modulated, red light 625 nm
• Supply voltage: 10 to 30 VDC
• Output: 100 mA, NPN or PNP, N.O & N.C.
• Degree of protection IP67, IP69K
• LED indication for output, stability and power ON
• Protection: reverse polarity, short circuit and transients
• Cable and plug versions
• Excellent EMC performance
• Wide detection angle - short blind zone
Type Selection
Housing style
Range Connection Ordering no. Ordering no.
Sn NPN PNP
Make & break switching Make & break switching
Specifications (cont.)
Environment Housing material
Installation category III (IEC 60664/60664A; Body ABS, grey
60947-1) Front material PMMA, red
Degree of pollution 3 (IEC 60664/60664A; Cable gland POM, Black
60947-1) Trimmer shaft POM, Dark Grey
Degree of protection IP 67, IP 69K* Locknuts PBTP, black
Ambient temperature Mounting bracket PPA, black
Operating -25° to +60°C (-13° to +140°F) Connection
Storage -40° to +70°C (-40° to +158°F) Cable PVC, grey, 2 m
Vibration 10 to 150 Hz, 1 mm/15 G 4 x 0.25 mm2, Ø = 4.5 mm
(IEC 60068-2-6) Plug M12, 4-pin
Shock 30 g / 11ms, 3 pos, 3 neg (CONB14NF-series)
per axis Weight With cable: 85 g
(IEC 60068-2-6, 60068-2-32) With plug: 25 g
Rated insulation voltage 500 VAC (rms) CE-marking Yes
IEC protection class III Approvals cULus (UL508)
supply class 2
* The IP69K test according to DIN 40050-9 for high-pressure, high-temperature wash-down applications. 90°
The sensor must not only be dust tight (IP6X), but also able to withstand high-pressure and steam cleaning.
The sensor is exposed to high pressure water from a spray nozzle that is fed with 80°C water at 8’000– 60°
10’000 KPa (80–100bar) and a flow rate of 14–6L/min. The nozzle is held 100 –150 mm from the sensor at
angles of 0°, 30°, 60° and 90° for 30s each. The test device sits on a turntable that rotates with a speed of 5
times per minute. The sensor must not suffer any damaging effects from the high pressure water in appea- 30°
rance and function.
0°
Operation Diagram
Operation Diagram
tv = Power ON delay
ON
Power supply OFF
Present
Object (Target) Not Present
ON Tv
Break Output (N.C.) OFF
ON Tv
Make Output (N.O.) OFF
Wiring Diagrams
NPN PNP
1 BN V 1 BN V
4 BK
2 WH
2 WH
4 BK
3 BU 3 BU
V GND V GND
Excess Gain
Ø 27
1.1 Operation level x 1.1
10
Time Ø 27
Green LED ON
Yellow LED ON
10
Detection Diagram Excess Gain
Sensor
Distance [inches]
Y
X R27 0 2.0 3.9 5.9 7.9 9.8 11.8 13.8 15.7 17.7 19.7
Kodac test card Distance [inches] 1000
0 3.9 7.9 11.8 15.7 19.7 23.6
60 0.20
40 0.13
100
Excess Gain
20 0.07
[inches]
[mm]
0 0
-20 -0.07
10
-40 -0.13
-60 -0.20
1
0 100 200 300 400 500 600 0 50 100 150 200 250 300 350 400 450 500
Sensing range [mm] Distance [mm]
Dimensions
Sensitivity Control 240° Operation Indicator (Yellow) Sensitivity Control 240° Operation Indicator (Yellow)
3 30 6.3 15 3 30 10.8 15
Ø 9.9
Emitter Emitter
Ø 4.5
M12x1 Plug
M18 x 1
M18 x 1
3.5 3.5
3.5 3.5
Optical Axis
Optical Axis 0.6 0.6
20.5 8.1 20.5 8.1 Power and Stability
Power and Stability Receiver Receiver
39.3 43.8 Indicator (Green)
Indicator (Green)
Mounting Systems
APA18-MB1
Installation Hints
To avoid interference from inductive voltage / Relief of the cable strain Protection of the sensing face Sensor mounted on a mobile carrier
current peaks, separate the proximity switch
cables from any other power cables. E.g.
Engine, contactor or solenoid cables
Incorrect Incorrect
Incorrect
Correct Correct
> 100 mm