Professional Documents
Culture Documents
Mcr-Structures Design Input Parameters - Revb
Mcr-Structures Design Input Parameters - Revb
1 Structural Materials 1
2 Structure size 1
3 Design assumptions 5
3.1 Boundary conditions ..................................................................................................... 5
3.2 Load assumptions ......................................................................................................... 5
3.2.1 Self-Weight ............................................................................................................. 5
3.2.2 Finishing ................................................................................................................. 5
3.2.3 Live Load (Machine, device, or equipment) ........................................................... 6
4 Structural weight 6
Steel for beams (H-Beam, RHS, SHS): JIS G 3101 Gr. SS400.
Steel for top joist, and C-stud wall: AS/NZS 1397 Grade G450Z275.
2 Structure size
3 Design assumptions
• Steel modules are modelled as “pinned connection” to Footing via anchor bolts.
• The secondary members such as C-floor joist, and C-stud are released moments both
ends.
3.2.1 Self-Weight
Structure material use: Steel
Density, gsw = 78.5 kN/m3 (Determined by software automatically)
3.2.2 Finishing
Bottom floor: gf = 10kg/m2 (including Vinyl flooring, Metal sheeting)
Top ceiling: gf = 45kg/m2 (Compound ceiling, hat purlin, Metal sheeting)
Side wall: gf = 45kg/m2 (Compound ceiling, hat purlin, Metal sheeting)
4 Structural weight
The rough structure weight (self-weight), which is exported from the analysis model (Etabs), is
6 tons for a unit (20 feet).