SDS R513A-Melange-refrigerant en 2020
SDS R513A-Melange-refrigerant en 2020
SDS R513A-Melange-refrigerant en 2020
MTGxxx
R513A
1.2. Relevant identified uses of the substance or mixture and uses advised against
Relevant identified uses Industrial and professional
Test gas/Calibration gas
Use for manufacture of electronic/photovoltaic components
Use as refrigerant
Laboratory use
Contact supplier for more information on uses
Uses advised against Consumer use not recommended
MULTIGAS
Company identification Route de l’Industrie 102
CH-1564 Domdidier
MTGxxx
R513A
For the complete H-sentences texts mentioned in that chapter, refer to Section 16
Hazard pictograms
GHS04
Signal word Warning
Hazard statements
H280 Contains gas under pressure; may explode if heated
Precautionary statements
P410+403 Protect from sunlight. Store in a well-ventilated place
3.1. Substances
(CAS-No.) 754-12-1
2,3,3,3-Tetrafluoropropene (EC-No.) 468-710-7 Flam. Gas 1, H220
(EC Index-No.) --- 55 – 57 %
(R1234yf) (Registration-No.) Press. Gas (Liq.), H280
01-0000019665-61
(CAS-No.) 811-97-2
1,1,1,2-Tetrafluoroethane (EC-No.) 212-377-0
(EC Index-No.) --- 43 - 45 % Press. Gas (Liq.), H280
(R134A) (Registration-No.)
01-2119459374-33
For the complete H-sentences texts mentioned in that chapter, refer to Section 16
Contains no other components or impurities which will influence the classification of the product
Page : 3/10
Revised edition n° : 10.0
SAFETY DATASHEET Revision date : 08/2019
MTGxxx
R513A
3.2. Mixtures
Not established
4.2. Most important symptoms and effects, both acute and delayed
May cause asphyxiation at high concentrations. Symptoms may include
loss of consciousness or motor skills. The victim may not be aware of the
asphyxia
Refer to section 11
4.3. Indication of any immediate medical attention and special treatment needed
Do not give adrenaline or similar drugs
MTGxxx
R513A
MTGxxx
R513A
Eye/face protection Wear goggles and a face shield when transfilling or breaking transfer
connections. Standard EN 166
Skin / hand protection Wear protective gloves when handling gas cylinders Standard EN 388-
Protective gloves against mechanical hazards
The selected protective gloves have to satisfy the specifications of EU
Directive 89/686 / EEC and the standard EN 374 derived from it
For short-term use
Material: Fluoroelastomer
Penetration time:> 480 min
Glove thickness: 0.7 mm
For long-term use
Material: Fluoroelastomer
Penetration time:> 480 min
Glove thickness: 0.7 mm
Have appropriate, chemical-resistant protective clothing ready for use in
emergencies
Respiratory protection Self-contained breathing apparatus (SCBA) or positive pressure air mask
must be used in oxygenated atmospheres. Standard EN 137 - Self-
contained compressed air device with a full face mask
Page : 6/10
Revised edition n° : 10.0
SAFETY DATASHEET Revision date : 08/2019
MTGxxx
R513A
MTGxxx
R513A
10.1. Reactivity
No reactivity hazard other than the effects described in sub-sections below
10.2. Chemical stability
Stable under recommended storage conditions
MTGxxx
R513A
12.1. Toxicity
Assessment Not very harmful for fish
14.1. UN number
Transport par road/rail Transport by sea Transport by air
ADR / RID IMDG IATA
1078 1078 1078
Page : 9/10
Revised edition n° : 10.0
SAFETY DATASHEET Revision date : 08/2019
MTGxxx
R513A
Labelling
ADR/RID
IMDG 2.2 : Non-flammable, non-toxic gases
IATA
14.7. Transport in bulk according to Annex II of Marpol and the IBC Code
Not applicable
15.1. Safety, health and environmental regulations/legislation specific for the substance or mixture
This safety data sheet complies with the requirements of Regulation (CE) No. 1907/2006
MTGxxx
R513A
Indication of changes Revised safety data sheet in accordance with commission regulation (EU)
No 2015/830
Abbreviations and acronyms ADR : European Agreement concerning the International Carriage
of Dangerous Goods by Road
CAS : Chemical Abstract Service number (USA)
CLP : Classification Labelling Packaging Regulation; Regulation
(EC) No 1272/2008
CSA : Chemical Safety Assessment
EIGA : European Industrial Gases Association
EINECS : European Inventory of Existing Commercial Chemical
Substances
EN : European Standard
ATE : Acute Toxicity Estimate
IATA : International Air Transport Association
IMDG Code : International Maritime Dangerous Goods Code
LC50 : Lethal Concentration to 50 % of a test population
OMoD : Swiss Ordinance on the movement of waste
PBT : Persistent, Bioaccumulative and Toxic
PPE: Personal Protection Equipment
REACH : Registration, Evaluation, Authorisation and Restriction of
Chemicals Regulation (EC) No 1907/2006
RID : Regulations concerning the international carriage of
dangerous goods by rail
RMM : Risk Management Measures
STOT-SE : Specific Target Organ Toxicity - Single Exposure
UN : United Nations
vPvB : Very Persistent and Very Bioaccumulative
WGK: Water Hazards Class
Hazard statements
H280 Contains gas under pressure; may explode if heated
Precautionary statements
P410+403 Protect from sunlight. Store in a well-ventilated place
Disclaimer of liability Details given in this document have been prepared based on the most
available reliable documents and are believed to be correct at the time of
going to press
They do not claim to be exhaustive and should be considered as a guide