Data Sheet

AC Motor Controller
dACi® Series F Inverter

The dACi® Series F inverter is designed to be used on


single drive or dual drive traction systems and for
pump actuation. Together, with Danfoss induction
motors type TSA, the motors and inverters are
matched and optimized to achieve best
performances.

The Danfoss inverter, dACi® Series F, leaves amble


space for other components on your application.
Series F is among the smallest inverters available on
the market. Still, it is packed with the latest in inverter
technology. For example, it features CAN-based
communication for optimized machine control and
includes a new driver board that manages all external
devices – including horns, valves, and electro-
mechanical brakes – thereby securing easy and cost-
effective wiring. It is also designed with AmpSeal
connector, and Insulated Metal Substrate (IMS)
technology.

Features

• CAN-based communication for


optimized machine control
• AmpSeal connector for enhanced
machine reliability
• IMS technology for improved power
control
• Setup via CAN bus or Windows based
via laptop

Comprehensive technical literature online


at powersolutions.danfoss.com

© Danfoss | Jul 2016 520L0963 | AI00000086en-US0201 | 1


Data Sheet
AC Motor Controller dACi SF

Technical data

Type: dACi 24/360 24/480 36/300 36/400 48/300 48/400 80/260


Size F6 F8 F6 F8 F6 F8 F8
Nominal battery voltage [V] 24 36 48 80
Input voltage range [V] (12 for t<50 ms) 16 to 36 18 to 50 24 to 62 40 to 105
Nominal current [A]1 180 240 150 200 150 200 130
Maximum current [A]2 360 480 300 400 300 400 260
Peak current [A]3 400 520 330 440 330 440 300
Output voltage [V]4 3 × 0 to 16 3 × 0 to 24 3 × 0 to 32 3 × 0 to 53
Dimensions mm [in] W 150 [5.91]
H 225 [8.86]
D 120 [4.72]
Power connectors M10
1 @ 8 kHz switching frequency

2 S2 - 2 min.

3 For 10 s

4 @ input voltage = nominal battery voltage

Interface, standard version


Type: dACi 24/xxx 36/48/xxx 80/xxx
7 Digital Inputs (X1: 1, 2, 3, 4, 5, 6, 28) high active
1 Analog Input (X1: 29) [V] 0 to 10
Incremental encoder 1 (X1: 11, 22, 32, 33 Level [V] 0/15 V, A, B (e.g. sensor bearing)
Supply 15 V, max 50mA
Motor temperature sensor (X1: 10, 21) Type PTC
Serial interface RS 485 (X1: 7, 12, 23, 30) -
CAN (X1: 8, 9, 19, 20, 34, 35) V2 0B

Digital ouputs Max. current [V]; (current range) Dither signal


24/xxx 36/48/xxx 80/xxx
Main contactor driver (X1: 26) low-side-switch 3.01 1.51 1.51 -
with inverse diode
Magnetic brake driver output (X1: 25) low-side- 3.01 1.51 1.51 -
switch with inverse diode
Programmable on/off outputs (X1: 15,16,27) low- 3.01 1.51 1.51 -
side-switch with inverse diode
Output for proportional valves (X1: 14) low-side (0 to 2.0)1 (0 to 2.0)1 (0 to 2.0)1 62.5 Hz; 0 to 300 mA
switches with inverse diodes current controlled,
superposed with dither-signal
1 Without overload and short circuit protection and open circuit detection.

2 | © Danfoss | Jul 2016 520L0963 | AI00000086en-US0201


Data Sheet
AC Motor Controller dACi SF

Optional Interface extension


Type: dACi 24/xxx 36/48/xxx 80/xxx
4 Digital Inputs (X2: 7, 8, 14, 15) high active
1 Analog Input (X2: 2) [V] 0 to 10
1 Analog Input (X2: 3 ; X2:11) [V] -10 to +10
1 Analog Input (X2: 4 ; X2:12) [mA] -20 to +20

Type: dACi Maximum current [V]; (current range) Dither signal


24/xxx 36/48/xxx 80/xxx
2 Programmable on/off outputs (X1: 16,17) low-side-switch 3.01 1.51 1.51 -
with inverse diode
2 Outputs for proportional valves (X10: 18) low-side switches (0 to 2.0)1 (0 to 2.0)1 (0 to 2.0)1 62.5 Hz; 0 to 300 mA
with inverse diodes current controlled, superposed with
dither-signal
2 Programmable digital inputs or digital outputs (X2: 22, 23) - -
1 Without overload and short circuit protection, but with open circuit detection.

Type: dACi 24/xxx 36/48/xxx 80/xxx


Incremental encoder 1 (X2: Level [V] 0/15 V, A, B (e.g. sensor bearing)
5, 13, 19, 20) Supply 15 V, max 50mA

Others
Ambient temperature range -40 to 50°C [-40°F to 122°F]
Max. heat-sink temperature @ full current 85°C [185°F]
Heat-sink switch off temperature 100°C [212°F]
Relative humidity 100%, condensation is allowed
Signal line connectors AMP-Seal; Molex mini-fit junior optional
IP protection IP 64 with membrane
EMC/ESD EN 12885
safety EN 1175
UL UL 583

© Danfoss | Jul 2016 520L0963 | AI00000086en-US0201 | 3


Danfoss can accept no responsibility for possible errors in catalogues, brochures and other printed material. Danfoss reserves the right to alter its products without notice. This also applies to products
already on order provided that such alterations can be made without changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

4 | © Danfoss | Jul 2016 520L0963 | AI00000086en-US0201