Pipe - Velocity - On Gravity Sloped Pipes

You might also like

Download as xls, pdf, or txt
Download as xls, pdf, or txt
You are on page 1of 3

Project: WATANI RESIDENTIAL DEVELOPMENT PHASE 1A

Location: KHALIFA - A, Abu Dhabi

Pipe Velocity in Gravity Pipe


Using, Manning Equation:

V= 1.486 x R 0.667 x S 0.5


n (0.01)
Where:
V = Average flow velocity in feet per second
R = Hydraulic radius in feet Value of R, based on cross sectional
= ID/4 for full flow Area of carrier pipe
= Cross Sectional Area/wetted perimeter 315 dia. 400 dia.
(3.1416*D^2/4))/(2*(3.1416)*r) 0.7609 1.3526
0.2344 0.3281
n = Manning flow coefficient 3.2465 4.1230
0.01 n factor, is conservative reliable estimate
associated with polyetylene pipes 160 dia. 200 dia.
S = Slope in feet per foot 0.2165 0.3382
0.1313 0.1641
1.6493 2.0609

Based on ID/4 FLUID FLUID


Full Flow VELOCITY Half or Quarter FLOW VELOCITY

160 Dia. 1.486 x 0.1632 x 0.1000 0.0242 1.486 x 0.2581 x 0.1000 0.0384
= = 2.42 Ft./Sec = 3.84 Ft./Sec
slope 1/100 n (0.01) 0.01 n (0.01) 0.01

200 Dia. 1.486 x 0.1886 x 0.0900 0.0252 1.486 x 0.2996 x 0.0900 0.0401
= = 2.52 Ft./Sec = 4.01 Ft./Sec
slope 1/125 n (0.01) 0.01 n (0.01) 0.01

315 Dia. 1.486 x 0.2472 x 0.0707 0.0260 1.486 x 0.3799 x 0.0707 0.0399
= = 2.60 Ft./Sec = 3.99 Ft./Sec
slope 1/200 n (0.01) 0.01 n (0.01) 0.01

400 Dia. 1.486 x 0.2994 x 0.0577 0.0257 1.486 x 0.4755 x 0.0577 0.0408
= = 2.57 Ft./Sec = 4.08 Ft./Sec
1/300 n (0.01) 0.01 n (0.01) 0.01
Project: WATANI RESIDENTIAL DEVELOPMENT PHASE 1A
Location: KHALIFA - A, Abu Dhabi

Pipe Velocity in Gravity Pipe


Using, Manning Equation:

V= 1.486 x R 0.667 x S 0.5


n (0.01)
Where:
V = Average flow velocity in feet per second
R = Hydraulic radius in feet Value of R, based on cross sectional
= ID/4 for full flow Area of carrier pipe
= Cross Sectional Area/wetted perimeter 315 dia. 400 dia.
(3.1416*D^2/4))/(2*(3.1416)*r) 0.7609 1.3526
0.2344 0.3281
n = Manning flow coefficient 3.2465 4.1230
0.01 n factor, is conservative reliable estimate
associated with polyetylene pipes 160 dia. 200 dia.
S = Slope in feet per foot 0.1018 0.3382
0.0898 0.1641
1.1335 2.0609

Based on ID/4 FLUID FLUID


Full Flow VELOCITY Half or Quarter FLOW VELOCITY

160 Dia. 1.486 x 0.1632 x 0.1000 0.0242 1.486 x 0.2004 x 0.0707 0.0211
= = 2.42 Ft./Sec = 2.11 Ft./Sec
1/200 n (0.01) 0.01 n (0.01) 0.01

200 Dia. 1.486 x 0.1886 x 0.0900 0.0252 1.486 x 0.2996 x 0.0707 0.0315
= = 2.52 Ft./Sec = 3.15 Ft./Sec
1/200 n (0.01) 0.01 n (0.01) 0.01

315 Dia. 1.486 x 0.2472 x 0.0707 0.0260 1.486 x 0.3799 x 0.0707 0.0399
= = 2.60 Ft./Sec = 3.99 Ft./Sec
slope 1/200 n (0.01) 0.01 n (0.01) 0.01

400 Dia. 1.486 x 0.2994 x 0.0577 0.0257 1.486 x 0.4755 x 0.0707 0.0500
= = 2.57 Ft./Sec = 5.00 Ft./Sec
1/200 n (0.01) 0.01 n (0.01) 0.01
Project: WATANI RESIDENTIAL DEVELOPMENT PHASE 1A
Location: KHALIFA - A, Abu Dhabi

Pipe Velocity in Gravity Pipe


Using, Manning Equation:

V= 1.486 x R 0.667 x S 0.5


n (0.01)
Where:
V= Average flow velocity in feet per second
R= Hydraulic radius in feet Value of R, based on cross sectional
= ID/4 for full flow Area of carrier pipe
= Cross Sectional Area/wetted perimeter
(3.1416*D^2/4))/(2*(3.1416)*r)
n = Manning flow coefficient
0.01 n factor, is conservative reliable estimate
associated with polyetylene pipes 110 dia.
S = Slope in feet per foot 0.1018
0.0898
1.1335

Based on ID/4 FLUID FLUID


Full Flow VELOCITY Half or Quarter FLOW VELOCITY

110 Dia. 1.486 x 0.1392 x 0.1000 0.0207 1.486 x 0.2004 x 0.0707 0.0211
= = 2.07 Ft./Sec = 2.11 Ft./Sec
1/200 n (0.01) 0.01 n (0.01) 0.01

You might also like