Technical Report No.

713034127 B
dated
2014-03-13

Client: Sensus GmbH Ludwigshafen


Industriestraße 16
67063 Ludwigshafen

Manufacturer and / or see client


location of manufacturing:

Unit/s under test (UUT): Water meter, iPerl;


Repeater, SRF-RP433;
Counter housing for water meter, ER301

Test specification: Sealing test re. test of degree of protection provided by enclosure in ac-
cordance to DIN EN 60529:2000

Test scope: Verification of suitability for intended application according the


under position 3 detailed test specification.

Test result: The units under test were not opened.


UUT 1-6 function test by data read-out successful.
UUT 7-12 no variations of yellow humidity granulate visible.
The presented units met the requirements.

This technical report may only be quoted in full. Any use for advertising purposes must be granted in writing. This report is the result
of a single examination of the object in question and is not generally applicable evaluation of the quality of other products in regular
production.
tec_tb_2004_e.dot 01.03.2006

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 1 of 17 Date of issue: 2014-03-13 Germany
Table of content

1 Unit/s under test (UUT)

2 Order
2.1 Date of order, initial of client
2.2 Receipt of UUT
2.3 Reconsignment of UUT

3 Test specification

4 Test equipment

5 Test sequence

6 Legend of measuring diagrams


n/a

7 Test documentation
n/a

8 Photo documentation

Integrated documentation
Customers’ log files of function tests UUT 1-6

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 2 of 17 Date of issue: 2014-03-13 Germany
1 Unit/s under test (UUT)

The units under test were each three water meters, repeaters and six counter housings for
water meters:

UUT Description Type Serial No. / ID No. Tests

1 8 SEN 01 10043662
Water meter with
2 iPerl S4 8 SEN 01 10043663
radio communication
3 8 SEN 01 10043664
4 1234 0002
Repeater with radio
5 SRF-RP433 1234 0006 IPX8
communication
6 1234 0014
7 1
8 2
9 Counter housing for 3
ER301
10 water meter ---
Reference to UUT 7-9
11 ---
outside immersion tank
12 ---

UUT 1-6 sealed by compound-filled housing;


UUT 7-12 filled by the client with yellow granulate for humidity indication.

2 Order

2.1 Date of order, initial of client

Company Sensus GmbH ordered from TÜV SÜD Product Service GmbH with order sheet dat-
ed 2013-12-03, order No. 4500448179 / 1000506 to test the a.m. UUT.

2.2 Receipt of UUT

The sample was delivered by the client on 2013-12-05.

2.3 Reconsignment of UUT

The samples were taken by the client on 2014-03-07.

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 3 of 17 Date of issue: 2014-03-13 Germany
3 Test specification

3.1 Degree of protection

3.1.1 IP X8

immersion tank
resulting immersion level: 1.5m to bottom edge of UUT
test duration: 3 months

4 Test equipment

Equipment Type Ser.-No. Manufacturer Calibrated to


Immersion tank X8 Deepness n. a. Self-made n. a.
max. 1,90 m

The measuring equipment is calibrated regularly according to the calibration instructions of


TÜV SÜD PRODUCT SERVICE GmbH. All calibrations are traced back to national standards.

5 Test sequence

Test date: from 2013-12-05 to 2014-03-07

No. Test Period Notes

1 Protection against 2013-12-05 to UUT 1-6 were not opened. Function test
water - IP X8 2014-03-07 by data read-out successful.
UUT 5 clouding inside housing visible
(see photo no. 10, section 8 photo doc-
umentation).
UUT 7-12 were not opened. No varia-
tions of yellow humidity granulate visible.

6 Legend of measuring diagrams

n/a

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 4 of 17 Date of issue: 2014-03-13 Germany
7 Test documentation

n/a

8 Photo documentation

1: UUT 1-3 before IPX8 testing 2: UUT 4-6 before IPX8 testing

3: UUT 7-12 before IPX8 testing 4: UUT 1-9 before IPX8 testing

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 5 of 17 Date of issue: 2014-03-13 Germany
5: UUT 1-9 during IPX8 testing 6: UUT 1-6 after IPX8 testing

7: UUT 7-12 after IPX8 testing 8: UUT 5 after test, front side (exemplarily)

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 6 of 17 Date of issue: 2014-03-13 Germany
9: UUT 5 after test, back side over view 10: UUT 5 clouding visible, detail

Verified Edited
Signature Signature

Hari Mountogianakis Marion Kuhn-Hellmuth


Dept. Vice-Manager Test Engineer

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 7 of 17 Date of issue: 2014-03-13 Germany
Integrated documentation – Customers’ log files of function tests UUT 1-6

1. Log file of UUT 1-6 before IPX8 testing:

tunneled_in;05/12/13-08:24:40;01;73;12;34;00;02;00;00;00;00;00;00;00;
Reading 000000000 Alarms 0x00
in;05/12/13-
08:24:41;08;61;12;34;00;02;00;00;00;00;00;00;DF;08;00;0F;03;00;00;00;00;00;00;13;07;0E;10;FE;2A;26
;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;04;0B;00;
3C;0F;FF;01;1A;71;A5;35;1D;00;00;00;00;00;00;00;00;00;75;91;75;91;
PAM accepted
Reading 000000000 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -11.0dBm
Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000000
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x26 Rem Lifetim 0x0000 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0443655477 Clear Alarm 029day CSText
FDR lastdel 0x7591 Log lastdel 0x7591

2. Log file of UUT 1-6 after IPX8 testing:

Executed by SensusRF_Runtime_Core.exe Version 1.5d


programmed by Andre Schey

tunneled_in;07/03/14-08:24:29;01;13;12;34;00;02;00;00;00;00;00;00;00;

Reading 000000000 Alarms 0x00

in;07/03/14-08:24:30;08;0F;12;34;00;02;00;00;00;00;00;00;96;08;00;0F;03;
00;00;00;00;00;00;13;07;0E;10;FE;2A;26;00;00;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;04;0B;00;3C;0F;
FF;01;1A;EA;EF;07;1D;00;00;00;00;00;00;00;00;00;81;C3;81;C3;

PAM accepted

Reading 000000000 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -47.5dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000000

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 8 of 17 Date of issue: 2014-03-13 Germany
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x26 Rem Lifetim 0x0000 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0451604231 Clear Alarm 029day CSText
FDR lastdel 0x81C3 Log lastdel 0x81C3

Further interpretation of SEMI:

Date and Time: 23/04/2014-21:37:11

Unit: liter

Alarms will be cleared automatically after: 029 days

LEAKAGE Activity 1 - Flag 0


Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

BROKEN PIPE Activity 1 - Flag 0


Parameters: 0x26
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000000
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

MAGNETIC TAMPER Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

LOW BATTERY Activity 1 - Flag 0


Time: no value

IMI FAILURE Activity 1 - Flag 0

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 9 of 17 Date of issue: 2014-03-13 Germany
VERY LOW BATTERY
Time: no value

REMAINING LIFETIME
Lifetime 0000days 00:00:00

MAXFLOW
Max value 00000
Time: no value

tunneled_in;07/03/14-08:24:37;01;C3;12;34;00;06;00;00;00;00;00;00;00;

Reading 000000000 Alarms 0x00

in;07/03/14-08:24:38;08;B2;12;34;00;06;00;00;00;00;00;00;81;08;00;0F;
03;00;00;00;00;00;00;13;07;0E;10;FE;2A;26;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;04;0B;
00;3C;0F;FF;01;1A;EA;F9;9A;1D;00;00;00;00;00;00;00;00;00;81;C3;81;C3;

PAM accepted

Reading 000000000 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -58.0dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000000
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x26 Rem Lifetim 0x0000 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0451606938 Clear Alarm 029day CSText
FDR lastdel 0x81C3 Log lastdel 0x81C3

Further interpretation of SEMI:

Date and Time: 23/04/2014-22:22:18

Unit: liter

Alarms will be cleared automatically after: 029 days

LEAKAGE Activity 1 - Flag 0


Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 10 of 17 Date of issue: 2014-03-13 Germany
BROKEN PIPE Activity 1 - Flag 0
Parameters: 0x26
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000000
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

MAGNETIC TAMPER Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

LOW BATTERY Activity 1 - Flag 0


Time: no value

IMI FAILURE Activity 1 - Flag 0

VERY LOW BATTERY


Time: no value

REMAINING LIFETIME
Lifetime 0000days 00:00:00

MAXFLOW
Max value 00000
Time: no value

tunneled_in;07/03/14-08:24:44;01;63;12;34;00;14;00;00;00;00;00;00;00;

Reading 000000000 Alarms 0x00

in;07/03/14-08:24:45;08;58;12;34;00;14;00;00;00;00;00;00;80;08;00;0F;03;00;00;
00;00;00;00;13;07;0E;10;FE;2A;26;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;04;0B;00;3C;0F;FF;01;1A;EA;EF;1E;
1D;00;00;00;00;00;00;00;00;00;81;C3;81;C3;

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 11 of 17 Date of issue: 2014-03-13 Germany
PAM accepted

Reading 000000000 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -58.5dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000000
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x26 Rem Lifetim 0x0000 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0451604254 Clear Alarm 029day CSText
FDR lastdel 0x81C3 Log lastdel 0x81C3

Further interpretation of SEMI:

Date and Time: 23/04/2014-21:37:34

Unit: liter

Alarms will be cleared automatically after: 029 days

LEAKAGE Activity 1 - Flag 0


Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

BROKEN PIPE Activity 1 - Flag 0


Parameters: 0x26
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000000
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

MAGNETIC TAMPER Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 12 of 17 Date of issue: 2014-03-13 Germany
LOW BATTERY Activity 1 - Flag 0
Time: no value

IMI FAILURE Activity 1 - Flag 0

VERY LOW BATTERY


Time: no value

REMAINING LIFETIME
Lifetime 0000days 00:00:00

MAXFLOW
Max value 00000
Time: no value

tunneled_in;07/03/14-08:24:51;01;C3;06;8F;22;0E;00;00;00;FD;00;00;00;

Reading 000000253 Alarms 0x00

in;07/03/14-08:24:52;08;B5;06;8F;22;0E;00;00;00;FD;00;00;9C;08;00;0F;03;00;00;00;00;
00;2E;13;07;0E;10;FE;2A;46;DA;55;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;04;0B;00;3C;0F;FF;01;1A;AC;30;60;1D;00;00;00;00;00;
00;00;00;00;81;05;81;05;

PAM accepted

Reading 000000253 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -44.5dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000046
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x46 Rem Lifetim 0xDA55 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0447492192 Clear Alarm 029day CSText
FDR lastdel 0x8105 Log lastdel 0x8105

Further interpretation of SEMI:

Date and Time: 07/03/2014-07:23:12

Unit: liter

Alarms will be cleared automatically after: 029 days

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 13 of 17 Date of issue: 2014-03-13 Germany
LEAKAGE Activity 1 - Flag 0
Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

BROKEN PIPE Activity 1 - Flag 0


Parameters: 0x46
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000046
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

MAGNETIC TAMPER Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

LOW BATTERY Activity 1 - Flag 0


Time: no value

IMI FAILURE Activity 1 - Flag 0

VERY LOW BATTERY


Time: no value

REMAINING LIFETIME
Lifetime 5781days 06:00:00

MAXFLOW
Max value 00000
Time: no value

tunneled_in;07/03/14-08:24:59;01;33;06;8F;22;0F;00;00;00;43;00;00;00;

Reading 000000067 Alarms 0x00

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 14 of 17 Date of issue: 2014-03-13 Germany
in;07/03/14-08:25:00;08;27;06;8F;22;0F;00;00;00;43;00;00;95;08;00;0F;03;00;00;00;00;
00;51;13;07;0E;10;FE;2A;46;DA;E7;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;04;0B;00;3C;0F;FF;01;1A;AC;30;3A;1D;00;00;00;00;00;
00;00;00;00;81;05;81;05;

PAM accepted

Reading 000000067 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -48.0dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000081
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x46 Rem Lifetim 0xDAE7 Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0447492154 Clear Alarm 029day CSText
FDR lastdel 0x8105 Log lastdel 0x8105

Further interpretation of SEMI:

Date and Time: 07/03/2014-07:22:34

Unit: liter

Alarms will be cleared automatically after: 029 days

LEAKAGE Activity 1 - Flag 0


Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

BROKEN PIPE Activity 1 - Flag 0


Parameters: 0x46
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000081
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 15 of 17 Date of issue: 2014-03-13 Germany
MAGNETIC TAMPER Activity 1 - Flag 0
Start: no value
End: no value
Delta: values not valid

LOW BATTERY Activity 1 - Flag 0


Time: no value

IMI FAILURE Activity 1 - Flag 0

VERY LOW BATTERY


Time: no value

REMAINING LIFETIME
Lifetime 5817days 18:00:00

MAXFLOW
Max value 00000
Time: no value

tunneled_in;07/03/14-08:25:07;01;43;06;8F;22;10;00;00;00;0C;00;00;00;

Reading 000000012 Alarms 0x00

in;07/03/14-08:25:08;08;37;06;8F;22;10;00;00;00;0C;00;00;A4;08;00;0F;03;00;00;00;00
;00;00;13;07;0E;10;FE;2A;46;DB;2F;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;00;
00;00;00;00;00;00;00;00;00;00;00;04;0B;00;3C;0F;FF;01;1A;AC;30;98;1D;00;00;00;00;00;
00;00;00;00;81;05;81;05;

PAM accepted

Reading 000000012 Alarms 0x00 PAMStat 0x00 RSSI (PAM) -40.5dBm


Metertype 008 ---------------->>> iPERL
TX Interval 00015s LAT Interval 003 Flow 00000 Reverse Vol 0000000
Units 0x13 OMS Status 0x07 OMS TX 03600s Alarm Active 0xFE
Leak Detect 0x2A Broken Detect 0x46 Rem Lifetim 0xDB2F Very Low Bat 0x0000
Max Flow 00000 Time Maxflow 0x0000 Low Bat Det 0x0000 Leak Start 0x0000
Leak End 0x0000 Magn Start 0x0000 Magn End 0x0000 Air Start 0x0000
Air End 0x0000 Backfl Start 0x0000 Backfl End 0x0000 Broken Start 0x0000
Broken End 0x0000 Log Content 0x040B Log Inter 00060min FDR Content 0x0FFF
FDR due day 01 Time 0447492248 Clear Alarm 029day CSText
FDR lastdel 0x8105 Log lastdel 0x8105

Further interpretation of SEMI:

Date and Time: 07/03/2014-07:24:08

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 16 of 17 Date of issue: 2014-03-13 Germany
Unit: liter

Alarms will be cleared automatically after: 029 days

LEAKAGE Activity 1 - Flag 0


Parameters: 0x2A
Start: no value
End: no value
Delta: values not valid

BROKEN PIPE Activity 1 - Flag 0


Parameters: 0x46
Start: no value
End: no value
Delta: values not valid

BACKFLOW Activity 1 - Flag 0


Reverse Volume 0000000
Start: no value
End: no value
Delta: values not valid

AIR IN SYSTEM Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

MAGNETIC TAMPER Activity 1 - Flag 0


Start: no value
End: no value
Delta: values not valid

LOW BATTERY Activity 1 - Flag 0


Time: no value

IMI FAILURE Activity 1 - Flag 0

VERY LOW BATTERY


Time: no value

REMAINING LIFETIME
Lifetime 5835days 18:00:00

MAXFLOW
Max value 00000
Time: no value

Accredited Test Laboratory Phone: + 49 621 395-891


Deutsche Akkreditierungsstelle GmbH Fax: + 49 621 395-604 TÜV SÜD Product Service GmbH
(DAkkS):
Reg.No. D-PL-11321-02-01 E-Mail: Marion.Kuhn-Hellmuth@tuev-sued.de Mannheim Branch
Dudenstraße 28
Rep.-No: 713034127B Editor: Marion Kuhn-Hellmuth 68167 Mannheim
Page 17 of 17 Date of issue: 2014-03-13 Germany

You might also like