Professional Documents
Culture Documents
Test Plan: 9520A300: Pump Specification
Test Plan: 9520A300: Pump Specification
Test Plan:
JCB 68.0 KW @ 2200 RPM (TCA 9520A300 Issue Date:
PUMP SPECIFICATION
Rotation: Anti-Clockwise.
Governor type: Mechanical all-speed.
Governor spring position : 2.
Gov. Link Length: 41.5 ± 0.5 mm.
Gov. Link Length: 10.1 ± 0.5 mm.
(DP210 Workshop Manual Section 4.6.4)
Plunger Diameter: 7.0 mm (4 off).
Drive Type: Supported shaft.
Transfer pressure: adjustable.
Viscosity compensating device in end plate.
Cambox pressurising valve.
Servo Advance with:
- Speed advance, LLA & CA
Torque trimmer.
Boost control.
Solenoid voltage: See Service Instruction Note DT294.
OEM Code: 320/06743 Setting Code: ........
OEM Code: 320/06749 Setting Code: ........
PRE-TEST NOTES
Screw transfer pressure adjuster fully in and then 4 turns
out before commencing test
No additional shimming is required.
CA solenoid to be de-energised unless otherwise stated.
Torque trimmer plug to be wound out until thread appears.
Boost control initial shimming: 0.2 mm.
Boost stroke : 4.9 to 5.1 mm.
Latch valve adjuster, if fitted, screw fully in then
8 turns out
Turn light load adjuster valve fully in ,then 2 turns out.
1/4
9520A300 Edition: 7
Test Plan:
JCB 68.0 KW @ 2200 RPM (TCA 9520A300 Issue Date:
2/4
9520A300 Edition: 7
Test Plan:
JCB 68.0 KW @ 2200 RPM (TCA 9520A300 Issue Date:
3/4
9520A300 Edition: 7
Test Plan:
JCB 68.0 KW @ 2200 RPM (TCA 9520A300 Issue Date:
4/4