Download as pdf or txt
Download as pdf or txt
You are on page 1of 8

LEHE1587-04

® ®
Cat C4.4 DIESEL GENERATOR sETs CAJ
STANDARD EQUIPMENT OPTIONAL EQUIPMENT

Control panels EMCP4.2 control panel. Exhaust Silencer System 10, 25, 35 dBA

Remote Annunciators
Radiator and cooling fan complete with NFPA110 bundle
protective guards. Control panels Oil temp guage & sender
Standard ambient temperatures up to Earth (Ground) Fault Relay
Cooling system Discrete i/o module
50degC (122degF).
50% coolant antifreeze/corrosion inhibitor.
Coolant Reservoir 3-Pole 100% Rated- Single & Dual breaker
Circuit Breakers
combination.

Primary & secondary fuel filters


Fuel system Sound Attenuated (SA)- Level 1 & Level 2
Flexible fuel lines. Enclosures
Weather Protective

Radiator Stone guards.


Brushless, self-excited 2/3 pitch, random Cooling system
Radiator transition flange
Generators and wound.
generator
attachments
IP23 Protection.
Insulation Class Hand temperature rise
r
Integrated Voltage Regulator Fuel System Integral & Sub Base Fuel Tanks: 146, 271 Gal

Governing system Cat Electronic Governor (ADEM A4).


Generators and
generator AREP, PMG
Safety Shutoff- Low Oil Pressure attachments
Protection System Safety Shutoff- Overspeed
Coolant Level Sensor
Starting/charging
Standard Battery Set
system
Starting/charging 12-Volt Electric Starting Motor
system Batteries with rack & cables Certifications IBC Seismic & Wind Certifications

Paint- Caterpillar Yellow except rails and


General General Tool Set
radiators gloss black

WEIGHTS & DIMENSIONS

Generator
Standby Dim"A" I Dim"B" Dim"C"
Set Weight1
Ratings mm(in) mm(in) mm(in)
I kg (lb)
C4.4 --1932 (76) I 1110 (44) 1767 (70) 890 (1962)
1
Weight includes: Oversize generator, skid base, circuit breaker, oil, and
coolant

LEHE1587-04 2/8

• •

• •

• •

• •

• •
• •
• •

• •






LEHE1587-04
Est. Fillable Usable Weight
Tank Generator Vent Length ‘L’ Width ‘W’ Height ‘H’
Engine Run Capacity Capacity (Dry)
Feature Set Rating
Model Time
Code ekW L gal L gal in mm in mm in mm in kg lb
hrs
40 36
INTFT140
50 29 520 137 508 134 3 533 21.0 336 740
SBT140
60 26
C4.4 2483 97.8 1000 39.4
40 68
INTFT250
50 55 965 255 952 251 3 864 34.0 466 1027
SBT250
60 49




LEHE1587-04
Cat C4.4 ®
ENCLOSURES

Weather Protective and Sound Attenuated


Enclosures
60 Hz

FEATURES

Robust / Highly Corrosion Resistant Construction Options


• Stainless steel flush fitting latches and hinges tested and • Weather Protective Enclosure
proven to withstand extreme conditions of corrosion • Sound Attenuated Enclosure – Weather protective
• Zinc plated or stainless steel fastener
with critical silencer
• Cat Yellow or white paint
Excellent Access • UL Listed fuel tanks
• Single side access for service and controls
• All non-service sides have removable doors and/or panels
• Radiator fill access Transportability
• These enclosures are of extremely rugged
• Lube oil and coolant drains piped to the exterior of the
enclosure base construction to withstand outdoor exposure and
rough handling common on many construction sites.
• Large cable entry area for installation ease
The sound deadening material is of a self-
• Double doors on both sides extinguishing design
• Vertically hinged doors with solid bar door stays to hold • This range of enclosures are designed on modular
doors in place when open principles with many interchangeable components
permitting on site repair
Security and Safety
• Lockable access doors which give full access to control
panel and breaker
• Cooling fan and battery charging alternator fully guarded
• Fuel fill, oil fill, and battery can only be reached via
lockable access
• Stub-up area is rodent proof.

LEHE- 1587-04 5/8


Cat C4.4 ®
ENCLOSURES

Enclosure Sound Pressure Levels (SPL) at 100%

Weather Protective Enclosure Cooling Air Flow Rate SPL @7m (23ft)

Model Standby ekW m3/s cfm dBA


D40-2LC 40 1.7 3602 85
D50-2LC 50 1.7 3602 86
D60-2LC 60 1.9 4026 88

Sound Attenuated Enclosure

Model Standby ekW m3/s cfm dBA


D40-2LC 40 1.7 3602 74
D50-2LC 50 1.7 3602 74
D60-2LC 60 1.9 4026 74

Note: The sound pressure level data shown above is quoted as free field and is for guidance only.
Weights & Dimensions
Actual levels produced may vary according to site conditions

Weights:
Skid Base WP Enclosure SA Enclosure
Model Standby ekW
kg lb kg lb kg lb
D40-2LC 40
D50-2LC 50 80 176 121 267 137 302
D60-2LC 60

Enclosure Dimensions: Skid Bases

Engine Generator Width ‘W’ Length ‘L’ Height ‘H’


Enclosure
Model Set Rating ekW mm in mm in mm in
40 Weather
50 Protective/
C4.4 1075 42.3 1972 77.6 1378 54.3
Sound
60 Attenuated

6/8
LEHE- 1587-04
Cat C4.4 ®
ENCLOSURES

Enclosure Dimensions: UL Listed Sub Tank Base.

Generator 137 Gallon Sub Base Tank 255 Gallon Sub Base Tank
Engine
Set Enclosure Length 'L' Height 'H' Length 'L' Height 'H'
Model
Rating ekW mm in mm in mm in mm in
40 Weather
C4.4 50 Protective/
2503 98.5 1912 75.3 2503 98.5 2241 88.2
Sound
60 Attenuated

Enclosure Dimensions: UL Listed Integral Tanks.

Generator 137 Gallon Sub Base Tank 255 Gallon Sub Base Tank
Engine
Set Enclosure Length 'L' Height 'H' Length 'L' Height 'H'
Model
Rating ekW mm in mm in mm in mm in
DIMENSIONS
40 Weather
C4.4 50 Protective/
2503 98.5 1712 67.4 2503 98.5 2041 80.4
Sound
60 Attenuated

LEHE- 1587-04 7/8






• •
• •


• •
• •


• •
• •
• •
• •


• •


• •
• •
• •
• •

www.Cat.com/electricpower
©2019Caterpillar. All rights reserved. Materials and specifications are subject to change without notice. CAT, CATERPILLAR, their
respective logos, ADEM, S•O•S, BUILT FOR IT, “Caterpillar Yellow”, the “Power Edge” trade dress as well as corporate and product
identity used herein, are trademarks of Caterpillar and may not be used without permission.

LEHE1587-04

You might also like