NOTE:
ALL FCU INSIDE ICT SHALL HAVE SECONDARY DRIP PAN.

KEY PLAN

BA FCU NOTES:
FCU 14
16 (DUTY)
P1-L03-002
SG-07 ICT
15 L/S FCU
EG-01 14
20 L/S (STAND BY)

FD FD
VCD VCD
FSC
200x200 LPD FA/TB ELEC. RISER P1-L03-003
ST 2-1C SMOKE STOP LOBBY
SG-09 STAIR SG-02
1805 L/s
140 L/S
1200x450 SPD FA/TB VCD
VCD

BB
150x150 FAD TB
150x150 EAD TB

200x200 LPD 200x200 LPD

P1-L03-004 Drawing Approval Status


OFFICE A - APPROVED
(Consultant / Contractor May Proceed)

B - APPROVED WITH COMMENTS


(Comments Shall be actioned to achieve A Before construction Utilization)

C - REVISE AND RESUBMIT


(Resubmission required)

D - REJECTED ( Not Required)


BC
E - FOR INFORMATION ONLY

Name :
Date :
REFERENCES
PHASE DRAWING NUMBER TITLE Rev. DATE
MECHANICAL GENERAL NOTES, LEGEND AND
IFC 9205-BP12B-MMJV-IFCD-ME-NS-000-00001 000 27 NOV 2020
SYMBOLS SHEET 1 OF 2
MECHANICAL GENERAL NOTES, LEGEND AND
9205-BP12B-MMJV-IFCD-ME-NS-000-00002 000 27 NOV 2020
SYMBOLS SHEET 2 OF 2
9205-BP12B-MMJV-IFCD-ME-NS-000-00010 MECHANICAL STANDARD DETAILS SHEET 1 OF 4 000 27 NOV 2020

9205-BP12B-MMJV-IFCD-ME-NS-000-00011 MECHANICAL STANDARD DETAILS SHEET 2 OF 4 000 27 NOV 2020

9205-BP12B-MMJV-IFCD-ME-NS-000-00012 MECHANICAL STANDARD DETAILS SHEET 3 OF 4 000 27 NOV 2020

9205-BP12B-MMJV-IFCD-ME-NS-000-00013 MECHANICAL STANDARD DETAILS SHEET 4 OF 4 000 27 NOV 2020


MECHANICAL PODIUM BUILDING EQUIPMENT
9205-BP12B-MMJV-IFCD-ME-NS-000-00022 000 05 FEB 2020
SCHEDULES SHEET 1 OF 3
MECHANICAL PODIUM BUILDING EQUIPMENT

BD 9205-BP12B-MMJV-IFCD-ME-NS-000-00023

9205-BP12B-MMJV-IFCD-ME-NS-000-00024
SCHEDULES SHEET 2 OF 3
MECHANICAL PODIUM BUILDING EQUIPMENT
000

000
05 FEB 2020

05 FEB 2020
SCHEDULES SHEET 3 OF 3
AIR CONDITIONING PODIUM BUILDING P1
9205-BP12B-MMJV-IFCD-ME-P1-000-00240 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 1 OF 2
AIR CONDITIONING PODIUM BUILDING P2
9205-BP12B-MMJV-IFCD-ME-P2-000-00241 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 1 OF 2
AIR CONDITIONING PODIUM BUILDING P3
9205-BP12B-MMJV-IFCD-ME-P3-000-00242 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 1 OF 2
AIR CONDITIONING PODIUM BUILDING P1
9205-BP12B-MMJV-IFCD-ME-P1-000-00243 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 2 OF 2
AIR CONDITIONING PODIUM BUILDING P2
9205-BP12B-MMJV-IFCD-ME-P2-000-00244 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 2 OF 2
AIR CONDITIONING PODIUM BUILDING P3
9205-BP12B-MMJV-IFCD-ME-P3-000-00245 000 05 FEB 2020
SCHEMATIC DIAGRAM SHEET 2 OF 2
PODIUM BUILDING P1 LEVEL L03
DD 9205-BP12B-MMJV-DWG-ME-P1-L03-00302 D02 25 OCT 2020
AIR CONDITIONING LAYOUT
MECHANICAL VENTILATION AND PIPEWORK
SD LUS-BP12B-F&P-DWG-ME-2PX58102-001 GA PLANS - PODIUM - L02 LL 02 16 AUG 2019
MECHANICAL VENTILATION AND PIPEWORK
LUS-BP12B-F&P-DWG-ME-2PX58102-002 GA PLANS - PODIUM - L02 HL 02 16 AUG 2019

BE
REVISIONS:

000 05 Feb 2021 ISSUED FOR CONSTRUCTION AF EP WY


FCU
14 Rev. Date Revision Details Drawn Chkd. Appd.
SG-01
(STAND BY)
20 L/S
Stage:
SLD-02 EG-01
125 L/s 25 L/S
ISSUED FOR CONSTRUCTION
4 NOS. 150Ø FLEXIBLE DUCT
200Ø FLEXIBLE DUCT FCU P2-PL-02 200x200 EAD
EG-01 P2-PL-01 Client:
200x200 SAD 14 LIFT CAV
500x250 SAD 30 L/S LIFT Lusail Real Estate Development Co
(DUTY) 25
Doha, State of Qatar
BF 150x150 TED SLD-01
48 L/s SG-13 800x800 EAD RISER TA/FB
EG-01 900x800 FAD RISER FA/TB
P1-L03-040 1820 L/S
35 L/s PM/CM :
6-VCD JAN (2 NOS.) P2-PL-03
5 NOS. CAV
VAV LIFT
FCU P1-L03-035 1400x450 RAD 32
VCD 09
FEMALE TOILETS VCD 900x400 EAD HL/TA 150x150 FAD C/W BELLMOUTH
07 VCD Designer:
500x250 SAD 600x300 EAD AND WIREMESH
VAV VCD 200x200 TED SLD-01
P1-L03-036 VAV 300x300 EAD RISER TA/FB
VCD 36 L/s
06 MALE TOILETS 61
P1-L03-037 SLD-01 2 NOS. 1900x700 F&B ZONE
200x200 FAD 900x400 EAD 300x200 FAD Supervision Consultant :
TOILET VAV
LOBBY 48 L/s FD
STUBOUT FOR 250x200 EAD DAR AL-HANDASAH
200x200 TED P1-L03-011 VCD P1-L03-012 SHAIR AND PARTNERS
09 TENANT POC VCD 200x150 EAD
P1-L03-041 EG-01 VCD MEP
VAV ICT 200x200 FAD
VCD 600x300 EAD FB Main Contractor :
09 VCD ACCESSIBLE TOILET 40 L/s VCD
350x500 EAD FB /LL VAV 150x150 EAD C/W BELLMOUTH
FCU VCD P1-L03-038
VCD AND WIREMESH
07
150x150 TED
6-VCD
BOH LOBBY
900x400 EAD HL/TA
VAV
62
900x400 FAD 200x200 FAD
150x150 EAD
MIC Construct
58 900x400 FAD
200x150 FAD VCD VCD
STUBOUT FOR P1-L03-013 600x300 EAD
900x400 EAD
FCU TENANT POC BOH LOBBY
VCD STUBOUT FOR TENANT POC 150x150 FAD
15 FD SG-03 Contractor's Lead Designer:
BG 150x150 EAD C/W BELLMOUTH
AND WIREMESH
300x300 LPD FA/TB
FD
500x350 EAD 137 L/S
1200x450 SPD FA/TB VCD P1-L03-014 EG-02
150x150 FAD C/W BELLMOUTH FCU EG-01 MSFD
VCD VCD ELEC. ROOM 75 L/S
AND WIREMESH CAV 01 MSFD
FD FD 20 L/S P1-L03-015
05 150x150 EAD HL VCD
FD 600x250 EAD WASTE
600x250 EAD RG-03 MSFD 200x150 FAD C/W BELLMOUTH
CAV 350x300 FAD HL 900x300 FAD AND WIREMESH Sub-Consultant:
350x300 TED 2-VCD 137 L/S
06 CAV 150x150 FAD
P1-L03-031 SG-02
SG-07 06 900x750 EAD TB SD-02
MEP 45 L/S ST 2-1A
15 L/s FD FD 50 L/S
900x400 FAD STAIR
CAV
STUBOUT FOR 1000x800 SPD FA/TB FCU
03 200x200 EAD TENANT POC
500x500 EAD TA/FB VCD 03
900x750 EAD TA/FB 600x400 LPD FA/TB
1000x850 FAD FA/TB VAV 250x200 RAD
250x250 LPD
200x200 TAD C/W BELLMOUTH 59 VCD 250x200 SAD
AND WIREMESH SG-02 150x150 EAD TB
EG-01 ST 2-1B P1-L03-016 P2-FL-01 150x150 FAD TB
100 L/S
20 L/s STAIR FF LOBBY LIFT
SG-02
78 L/s
Project Name:
400x600 LPD FA/TB LUSAIL PLAZA TOWERS
BH 1000x700 SPD FA/TB 150x150 FAD FROM LL
PLOT 2 (BP12B)
150x150 EAD FA/TB 150x150 FAD FA/TB
FCU P1-L03-033 P1-L03-017 FCU
Drawing Title:
16 STORAGE PANTRY 15
150x150 FAD FA/TB
150x150 FAD FROM LL 150x150 EAD FA/TB
150x150 EAD TO LL 150x150 EAD FROM HL PODIUM BUILDING P1 LEVEL L03
150x150 EAD C/W BELLMOUTH
AND WIREMESH AIR CONDITIONING LAYOUT
150x150 FAD C/W BELLMOUTH
AND WIREMESH Drawn: A. FERNANDEZ Size : A0
900x750 EAD TB
Checked: E. PASTRANA Scale @ A1: 1 : 100
Approved: W. YAKOB Date: 05 Feb 2021
Drawing Number: Revision:

9205-BP12B-MMJV-IFCD-ME-P1-L03-00302 000
Sheet : 01 of 01