edsx6_139a
8/75$621,&)/2:0(7(5 3257$)/2:&
'$7$6+((7 )6&)6'
PORTAFLOW-C is a portable type ultrasonic flowmeter
utilizing the transit time measuring method, using a clamp-
on type detector.
It is a compact and lightweight instrument incorporating the
latest electronics and digital signal processing technologies,
realizing high performance and easy operation.
)($785(6
&RPSDFWDQGOLJKWZHLJKW
The adoption of the latest electronics and digital
signal processing technologies has reduced the size
and weight of the flow transmitter by 30% and 30%, )ORZWUDQVPLWWHU )6&
respectively, in comparison with the Fuji conventional
portable flowmeter (Model FSC). (in comparison to
our existing model)
%DWWHU\RSHUDWLRQ
The flowmeter is designed for 12 hours of continu- 'HWHFWRUIRUWUDQVLWWLPH )6'
ous operation via built-in battery which is recharge-
able in 3 hours with the exclusive power adapter.
)XOOYDULHW\RIGHWHFWRUV
The flowmeter is suitable for various types of detec-
tors applicable for small to large diameter pipe (pipe
inner diameter φ13 to φ6000mm) and low to high
'HWHFWRUIRUKLJKWHPSHUDWXUH )6'
temperature (−40 to +200°C).
+LJKDFFXUDF\DQGKLJKVSHHGUHVSRQVH
The flowmeter is designed for high accuracy *UDSKLFSULQWHUFRQQHFWLRQ RSWLRQ
(±1.0%). Easy recording with the Integral type printer.
Response time is within 1 second. )ORZYHORFLW\SURILOHPHDVXUHPHQW RSWLRQ
,PSURYHGDQWLEXEEOHFKDUDFWHULVWLF Flow profile may be observed in real time.
Anti-bubble characteristic is greatly improved by
digital signal processing. 63(&,),&$7,216
([FHOOHQWSHUIRUPDQFHDQGHDV\RSHUDWLRQ
Large graphic LCD that is outside but easy to read. 0HDVXULQJREMHFWV
Minimum number of function keys are used for page
0HDVXUHPHQWIOXLG
selection, allowing easy setting.
Uniform liquid in which ultrasonic
While battery is working, the flowmeter is water waves can propagate.
resistant and tolerates exposure to rain. 7XUELGLW\RIIOXLG10000 mg/L or less
/DUJHFDSDFLW\VWRUDJHE\6'PHPRU\FDUG 6WDWHRIIOXLG Well-developed turbulent or laminar
Measured data is periodically stored in SD memory flow in a filled pipe.
card. For example, in the case of 256MB (option), it )OXLGWHPSHUDWXUH−40 to +200°C
can be saved about 1 year measurement date(In case 0HDVXULQJUDQJH0···±0.3 to ±32m/s
of saving period 30 seconds, 14 kinds of saved data).
Available up to 8MB. 3LSLQJFRQGLWLRQV
6HULDOFRPPXQLFDWLRQ
$SSOLFDEOHSLSLQJPDWHULDO
Use of a USB port allows easy connection to a per-
Select from carbon steel, stainless
sonal computer. Measured date collection panel and
steel, cast iron, PVC, FRP, copper,
Loader software for PC (standard) which is available
aluminum, acrylic or material of known
for display and change of parameter (site setting) are sound velocity.
prepared. 3LSHVL]H Flow rate measurement
+HDWTXDQWLW\ FDORULH PHDVXUHPHQW φ13 to φ6000mm
Heat quantity (calorie) may be measured by tem- Flow velocity profile measurement
perature input, making energy management easy for φ40 to φ1000mm
cooling and heating.
('6;J
'DWH $SU
)6&)6'
Heat
Heat
)6&)6'
0HWKRGIRUFRQQHFWLRQ
Flow transmitter side
0($685,1*35,1&,3/(
Exclusive connector With ultrasonic pulses propagated diagonally between the
Detector side upstream and downstream sensors, flow rate is measured
Large/middle type: Screw terminal by detecting the time difference obtained by the flow of
Others: BNC connector fluid. Detector
$PELHQWWHPSHUDWXUH−20 to +60°C Upstream sensor
$PELHQWKXPLGLW\ Large/middle type sensor:
100%RH or less θ Output
Flow signal
Others: 90%RH or less t2
D trans-
mitter
7\SHRIHQFORVXUH Flow
velocity V
t1
transmitter
4 to 20mA
DC
Flow
:KHQ=PHWKRGLVXVHGIRUPRXQWLQJ
Cable
Detector
transmitter
4 to 20mA
DC
Flow
'(7(&7256(/(&7,21*8,'(
Fluid Inner diameter of piping ø (mm)
Type (Name) temperature Mounting
[°C] method 13 25 50 100 200 250 300 400 1000 3000 6000
*2)
FSD22
−40 to 100 V 13 100
(Small diameter)
V 50 300
FSD12 −40 to 100
*1)
(Small type) Z 150 400
V 200 600
FSD41
−40 to 80
(Middle type)
Z 400 1200
FSD32 V 50 250
−40 to 200
(High-temperature) *1)
Z 150 400
*1) When FSD12 or FSD32 is mounted using the Z-size method, guide rail (option) is required additionally.
*2) For the pipe inner diameter of φ13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness.
When the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%.
<Description of the table> Required min. pipe thickness (fluid: water) (Unit: mm)
It shows pipe thickness of each material that the sensor mounting Steel pipe 2.15 or more FRP 3.21 or more
size is to be 0.0mm, when fixing a pipe. If the fluid is the one other Stainless pipe 1.87 or more Ductile cast iron 2.15 or more
than water, and if the sound velocity of fluid is faster than the one PVC pipe 3.69 or more PEEK 3.69 or more
of water, the sensor mounting size is to be 0.0mm or more. Copper pipe 3.82 or more PVDF 3.69 or more
Cast-iron pipe 2.98 or more Acrylic pipe 2.90 or more
Aluminum pipe 1.99 or more Polypropylene 3.69 or more
)/2:9(/2&,7<352),/(',63/$<)81&7,21 0HDVXUHPHQWSULQFLSOH
237,21 3XOVH'RSSOHUPHWKRG!
Ultrasonic pulses are transmitted through the fluid flow.
Flow velocity profile can be observed in real time using Entrained bubbles and microscopic particles within the
the dedicated detector from the outside. It is specifiable fluid create frequency phase shifts (Doppler effect.) The
by the code symbol of flow transmitter. resulting doppler shifts are integrated across the inside
pipe diameter cross section. The resulting profile curve
0RXQWLQJPHWKRG
Mounting on outside of existing pipe
$PELHQWWHPSHUDWXUH−20 to +80°C
8VLQJWZRVHQVRUV
$PELHQWKXPLGLW\ 100% RH or less
7\SHRIHQFORVXUH Cable
Power
supply
IP67 (with waterproof BNC connector Sensor (FSD)
provided.)
0DWHULDO Sensor housing: PBT
Flow
Guide frame: Aluminum alloy Transmitter
Mounting belt: Plastic cloth belt/stain-
less belt Sensor (FSD)
)6&)6'
7DEOH
Maximum measurement range of Pulsed Doppler method.
When nominal thickness of a stainless pipe of pipe material is Sch20s and the
fluid is water, the maximum measurement range varies depending on the outer
diameter of pipe, nominal thickness, material, or fluid type.
3&/RDGHUVRIWZDUH
Equipped as standard
• PC/AT compatible machines. (Operation on custom built
PCs or shop-brand PCs cannot be guaranteed.) &2'(6<0%2/
• Major functions: Performs parameter (site setting)
display /change of the main unit and
)ORZWUDQVPLWWHU!
1 2 3 4 5 6 7 8 9 10 11
collects measured date.
F SC 1 - 0 Description
Instantaneous velocity, instantaneous flow
<Specification>
rate, total value, error information, received S Standard
waveform, analog input, logger data, etc. may <Converter>
be downloaded in a personal computer. 1 Basic system
2 Basic system + Printer
• O/S: Windows2000/XP/Vista*
<Flow velocity profile measurement>
• Memory requirement: 128MB or more 0 None
• Disk unit: Windows2000/XP/Vista-compatible CD-ROM 1 Provided (detector to measure flow
velocity profile is separately required.)
drive
<Power adapter>
• Hard disk drive capacity: Free space of 64MB or more A AC power + power cord (125V AC) for
Japanese and North American use
B AC power + power cord (250V AC) for
* Windows Vista: Use it in basic mode. European and Korean use
It is not available for Windows Aero. C AC power + power cord (250V AC) for
Chinese use
1 Modification No.
<SD memory card>
0 None
1 Provided (256MB)
<Bound instruction manual/Language>
Y None (Factory-set language: English)
J Provided/Japanese
(Factory-set language: Japanese)
E Provided/English
(Factory-set language: English)
C Provided/Chinese
(Factory-set language: Chinese)
(Note1) Instruction manual contained in CD
is the standard attached article.
(Note2) You can change the language by
key operation.
'HWHFWRU!
IRUWUDQVLWWLPH
237,21$/,7(06
1 2 3 4 5 6 7 8 Name Specifications Arrange-
F SD Description ment No.
<Kind> 1 Battery Special type Li-ion battery ZZP∗TK7N6384P1
1 2 Small type (for φ50 to φ400mm) *1) *2) (7.4V, 2500mAh)×2
2 2 Small diameter (for φ13 to φ100mm)
4 1 Middle type (for φ200 to φ1200mm) 2 Power Special type power adapter
5 1 Large type (for φ200 to φ6000mm) adapter 90 to 264V AC, 50/60Hz
3 2 High-temperature (for φ50 to φ400mm) *1) *2) · AC power adapter ZZP∗TK7N6383P1
· Power connector conversion code ZZP∗TK4J2637C1
<Terminal mold> 3 Power code Japan, North America:125V AC 2m ZZP∗TK7N6621P1
0 None Europe, Korea: 250V AC 2m ZZP∗TK7N6608P1
1 Provided (Middle/Large type only) China: 250V AC 2m ZZP∗TK7N6609P1
<Structure> 4 Printer unit To be mounted on top of converter ZZP∗TK4J2634C1
Y General use Thermal serial dot system (8 x 384
1 Modification No. dot)
5 Printer roll Maker: SEIKO I SUPPLY Co. Ltd. ZZP∗TK7N6381P1
1RWH paper Type: TP-211C-1
*1) Applicable diameter range: Specifications: Thermal roll paper
V method: φ50 to φ250 (FSD32), φ50 to φ300 (FSD12) Width: 58mm×ø48mm, No core
Z method: φ150 to φ400 (FSD32, FSD12) 6 Silicone Maker: Shin-Etsu Chemical Co., Ltd.
Use the optional guide rail, if a pipe that does not allow ultrasonic grease Type:
waves to pass through easily, such as when an old pipe, cast iron · For standard use G40M, 100g ZZP∗45231N5
· For high temperature KS62M, 100g ZZP∗TK7G7983C1
pipe or a pipe with mortar lining is used, or the flow or liquid high
in turbidity is measured. Employ the Z method for mounting. 7 Signal cable Special type signal cable, 5m × 2
· Connector on both sides ZZP∗TK7N7795C1
IRUIORZYHORFLW\SURILOHPHDVXUHPHQW · FSD41 (Connector on one side) ZZP∗TK7N7795C2
1 2 3 4 5 6 7 8
· FSD51 (Connector on one side) ZZP∗TK7N7795C3
· BNC adapter (×2) ZZP∗TK7N6323P11
F SD 0 Y 1 Description
8 Extension Special type coaxial cable with BNC
<Kind> signal cable connector
P2 Small type (F40 to F200mm) · 10m × 2 ZZP∗TK468664C3
P1 Middle type (F100 to F400mm) · 50m × 2 ZZP∗TK468664C4
P0 Large type (F200 to F1000mm)
9 Analog 6-core cable, 1.5m, with connector ZZP∗TK4J2639C1
<Terminal mold> input/output
0 None cable
<Structure> 10 Mounting · Small type/small diameter sensor: ZZP∗TK7G7979C1
Y General use belt /wire Plastic cloth belt
1 Modification No. · Large type sensor:
Stainless wire
Nominal diameter
f200 to f500mm ZZP∗TK7G7980C1
)6&)6'
'LDJUDP 7RFRQQHFWVLJQDOFDEOHVIRU)6')6')6')6'3)6'3)6'3
%1&
FRQQHFWRU
([FOXVLYHXVHVLJQDOFDEOH
3ULQWHU 'HWHFWRU
RSWLRQ
7RFRQQHFWVLJQDOFDEOHVIRU)6')6'
%1&FRQQHFWRU
'HWHFWRULQSXW 6LJQDOFDEOH
3257$)/2:
'HWHFWRU
WKHGRZQVWUHDPVLGH
)ORZ
WUDQVPLWWHU 'HWHFWRULQSXW
WKHXSVWUHDPVLGH %1&DGDSWRU
21 2))
(6& $QDORJLQSXWRXWSXWFDEOH
$2DQDORJRXWSXWWRP$'&
)(('
(17
3ULQW
0(18
$,&+DQDORJLQSXWWRP$'&RUWR9'&
$,&+DQDORJLQSXWWRP$'&
&+$5*( '&,1
3&
6' 3RZHUFRQQHFWRU $&WR9
&RQYHUVLRQFRUG
6'PHPRU\ 3RZHUFRUG
FDUG $&SRZHUDGDSWRU
86%FDEOH IRUXVH$&DGDSWRU
7RFRQQHFW3&
&RQGLWLRQVRQVWUDLJKWSLSH
(D: Nominal diameter of pipe)
Type Length of upstream straight pipe Length of downstream straight pipe
L ≥ 5D
10D or more
L ≥ 10D
90° bend
Detector
10D or more
L ≥ 10D
L ≥ 50D
Tee
10D or more
or more
L ≥ 30D L ≥ 5D
0.5D
Diffuser
1.5D or more
L ≥ 10D L ≥ 50D
Contraction pipe
L ≥ 30D L ≥ 10D
Valve
Isolation valve
Check valve
L ≥ 50D
Pump
P
287/,1(',$*5$0 8QLWPP
)ORZWUDQVPLWWHU
120±1.8 65±1.8
PORTAFLOW
Sensor (downstream)
DOWNSTREAM
SENSOR
UPSTREAM
210±2.5
Sensor (upstream)
AI/AO
DC12V
ON OFF
FEED
ESC
Analog input/output
ENT
Print
MENU DC power input
CHARGE DC IN
Power switch
)6&)6'
287/,1(',$*5$0 8QLWPP
)ORZWUDQVPLWWHU ZLWKSULQWHU
120±1.8 65±1.8
Printer
PORTAFLOW
Sensor (downstream)
DOWNSTREAM
SENSOR
UPSTREAM
Sensor (upstream)
AI/AO
DC12V
ON OFF
Analog input/output
FEED
ESC
ENT
Print DC power input
MENU
CHARGE DC IN
Power switch
287/,1(',$*5$0 8QLWPP
Saddle
Saddle
Scale(inch) Scale(mm)
Connector
Scale (inch) Scale (mm)
mm
Connector
Spacing: 0 to 133
Name prate Name plate
Spacing: 0 to 348
320±2
Lock nut
540±2
Element holder
inch
Element holder
Cursor 36±0.5
90max.
36±0.5
90max.
52.5±0.5 52.5±0.5
Weight : Approx. 0.8kg Weight : Approx. 0.6kg
Name plate
Connector Saddle
54±2
Scale(inch) Scale(mm)
(114)
Sensor
Name plate
two sensors 0 to 330
Distance between
A
37±1 Wire rope Mounting spring
530±2
46±1
(ø19)
Lock nut
Element holder
Cursor
ø4.3 Cable BNC Connector
Ǿ26 33±0.5
8.5 8
90max.
+200
205max. 5000 −0
)6&)6'
287/,1(',$*5$0 8QLWPP
Name plate
Wire rope BNC connector
Mounting spring
92±2
Sensor unit
(114)
78±1
Detector A
Type.
Mfd.
L
(ø19)
67±2
Absorber unit
Ser.No.
ø4.3 BNC Connector
Made in Japan
Cable
8.5 8
+200
5000 −0
Frame
Weight : Approx.2.2kg
'HWHFWRU)6' /DUJHW\SH
Clip
(H)
Straight plug
(ø12.3)
AO
AI ch1
AI ch2
(ø5)
W±1
+100
1500 -0 100±5
'HWHFWRU)6'3 'HWHFWRUIRUIORZYHORFLW\SURILOHPHDVXUHPHQW
$QDORJLQSXWRXWSXWFDEOH
Caution on Safety
*Before using this product, be sure to read its instruction manual in advance.
Fuji Electric
Your distributor:
Coulton Instrumentation Ltd
17 Somerford Business Park, Christchurch, BH23 3RU, UK
Tel: +44 1202 480 303
E-mail: sales@coulton.com
Web: www.coulton.com
Information in this catalog is subject to change without notice. Printed in Japan