Professional Documents
Culture Documents
Brochure Natural Slate Rainscreen Cladding Systems Cupaclad Uk
Brochure Natural Slate Rainscreen Cladding Systems Cupaclad Uk
Brochure Natural Slate Rainscreen Cladding Systems Cupaclad Uk
CLADDING SYSTEMS
NATURAL
SLATE RAINSCREEN
CLADDING SYSTEMS
CONTENTS
Modern, contemporary
Lightweight and versatile.
design.
Developed alongside
Danish architects and
contractors CUPACLAD®
CUPACLAD®, NATURAL SLATE RAINSCREEN CLADDING 03
systems offer a revolution
SYSTEMS. in cladding applications for
natural slate. The systems
NATURAL SLATE, A UNIQUE MATERIAL. 04 offer a new durable,
CUPACLAD®, THE SUSTAINABLE CLADDING. 05 sustainable and easy to fix
alternative with a unique
THE EFFICIENCY OF A VENTILATED CLADDING. 06 character.
07
CUPACLAD® SYSTEMS.
| 03 |
NATURAL
SLATE,
CUPACLAD®, THE SUSTAINABLE CLADDING
A UNIQUE
MATERIAL CUPACLAD® natural slate systems are the perfect alternative for an efficient and sustainable
cladding.
Due to the nature of the slate production process, our CUPACLAD cladding has a lower environmental impact than
other man made alternatives. 5 times less CO2 emissions than fibre cement, 324 times less water consumption than
Slate is a natural product of zinc cladding and 10 times less energy consumption than clay.
unparalleled technical properties
that adds value to any project.
CUPACLAD® slate x1
Fibre cement x5
Zinc x9
Clay x8
AIR POLLUTION
CUPACLAD® slate x1
Durability Character
friendly WATER CONSUMPTION
Clay x20
Used since roman times, natural slate Each slate is handcrafted by our ski- Characterised by its natural colour
CUPACLAD® slate x1
is long–lived, remarkably durable, fire lled “splitters”, with no additional and individual texture, natural slate is
resistant and naturally waterproof. treatment required. Natural slate is a material that can enhance the va- Fibre cement x7
Its aesthetic and technical properties only subject to extraction and me- lue and beauty of any property. Every Zinc x9
remain unaltered, keeping the ele- chanical transformation; there are no slate is unique giving an unparalleled
Clay x10
gance and character for much longer chemical or heating processes invol- character to any project remaining ENERGY CONSUMPTION
than any man made alternatives. ved as with alternative materials. This unaltered for many years.
*Life-cycle assessment, studies all the stages of a product’s life from production to recycling. Data calculated for 1 square meter in a year. Sources: CUPACLAD® slate
and its unparalleled durability result (http://goo.gl/K5ILx8); Fibre cement (http://goo.gl/OSjeV5); Zinc (http://goo.gl/EgWh6g); Terracotta (http://goo.gl/Y03c9U).
LIFE-CYCLE
CUPACLAD® ASSESSMENT
larity and flatness of the slates, which material. Our CUPACLAD® sla- PRODUCTION
SLATE CLADDING are delivered with the holes made to te cladding meets and exce-
Life-cycle assessments allow
match the selected CUPACLAD® sys- eds the highest European quality
measurement of the environ-
RAW MATERIALS
tem. Even its packaging, which is sma- standards. mental footprint from a cradle to EXTRACTION
TRANSPORT
CUPACLAD® natural slate is spe- ller and lighter, has been designed to grave perspective. They confirm
PRODUCT LIFE
cially selected from among our 16 facilitate and shorten installation times. CUPACLAD® as a sustainable op- CYCLE
quarries for its technical properties CUPA PIZARRAS have been quarrying tion for cladding due to the use
of natural slate versus man-made
and is subjected to specific qua- natural slate for more than 120 years.
products.
lity controls to guarantee excep- Our quality control experts choose the END OF LIFE INSTALLATION
tional performance in any facade. perfect slate for each system based on
CUPACLAD® ensures quick and easy wind load and impact criteria to gua-
installation thanks to the greater regu- rantee its performance as a cladding
SERVICE LIFE
| 04 | | 05 |
THE EFFICIENCY Rainscreen cladding is a
CUPACLAD® systems have been developed to be able to adapt to any kind of project
combining alternative fixing methods and slate formats.
Simple and balanced Dynamic and creative Uniform and regular Modern and efficient
MAIN ADVANTAGES:
Structural
Elimination Energy
movement Durability
of Humidity savings
reduction
P.09 P.10 P.11 P.19
Rainwater penetration The air cavity avoids Thermal efficiency is in- The cladding material is
is greatly reduced and temperature varia- creased due to the coo- kept dry due to conti-
any moisture is removed tions resulting in less ling effect in summer nuous ventilation. Many
through the constant pronounced structural and greater heat reten- issues related to humi-
ventilation, reducing movements. This redu- tion in winter. dity (efflorescence etc…)
the risk of any conden- ces the risk of cracks and are reduced resulting in
sation. other structural issues. a longer life span of the
installation.
| 06 | | 07 |
101 SERIES Slates are fixed using our specially designed screws self-drilling to ensure
FIXING optimal installation while remaining completely invisible to minimize design
METHOD impact.
Screws are made of stainless steel with a large flat head that enables an ea-
sier and more secure fixing.
101
CUPACLAD® 101 Logic system utilizes
40x20cm slates fitted horizontally with invi-
sible fixings.
SERIES
Slates per m2 16.7
| 08 | | 09 |
CUPACLAD® 101 Random CUPACLAD® 101 Parallel
DYNAMIC AND CREATIVE UNIFORM AND REGULAR
CUPACLAD® 101 Random combines different CUPACLAD® 101 Parallel features a regular de-
slate sizes, creating a dynamic and unique de- sign with even joints. This results in a uniform
sign. and consistent layout that highlights the cha-
racter of natural slate.
CUPACLAD ®
101 Random features 50x25,
50x20 and 50x15 slates fitted horizontally CUPACLAD® 101 Parallel features 40x25 ho-
with invisible fixings. rizontally aligned slates fitted with invisible
screws.
50x25 cm
Slate size 50x20 cm
50x15 cm Slate size 40x25 cm
Nominal thickness 7.65 mm
Nominal thickness 7.5 mm
Slates per m2 ± 15
Slates per m 2 14.3
Weight per m2 (slate) ≤30 kg/m2
Weight per m (slate)
2 ≤30 kg/m2
| 10 | | 11 |
CUPACLAD®
SERIES 101
FIXING
METHOD
1 2 5 6
Fixing the metal brackets Fixing of insulation Fixing the flashings Fixing the first course slate
The metal brackets are installed in alternate courses on Choose the most suitable insulation material based on Fix a ventilation flashing at the first course of the cladding Cut a slate to a height of 80 mm approx. Fix it inverted
each side of the vertical profile. It is required to use both the project requirements. and the metal flashings at single points (edges, window matching the bottom edge of the slate with the first 101
fixed point metal brackets (on the upper end of each pro- Fixing in accordance with the manufacturers recommen- frames, etc...). horizontal profile.
file) and brackets with an sliding point to allow for expan- dations.
sion of the profile.
3 4 7
Fixing the “L” shaped profiles Fixing the CUPACLAD® 101 horizontal profiles Fixing the slates with the self-drilling
CUPACLAD® 101 screw
Fix the vertical profiles to the metal brackets allowing at Fix the horizontal profiles with the vertical ones at each
least 2 cm for an air cavity. intersection. Each slate must be aligned with the upper edge of the
The vertical profiles must be perfectly level before fitting The horizontal profiles must be perfectly level as their po- profile and fitted with two stainless steel. CUPACLAD® 101
the remainder of the system components. sition will dictate the final position of the slates. Fit also self-drilling screws.
an inverted 101 horizontal profil at the first course of the
cladding to allow fixing of the first course slate.
| 12 | | 13 |
TECHNICAL DOSSIER | CUPACLAD® 101
TECHNICAL DETAIL CUPACLAD® 101 Logic TECHNICAL DETAIL CUPACLAD® 101 Random TECHNICAL DETAIL CUPACLAD® 101 Parallel CONSTRUCTION DETAILS
CUPACLAD® 101 (Logic, Random Y Parallel)
500
400
VENTILATED PROFILE AND TOP FLASHING
400 Ø4
32
100 350
A
250
Ø4
32
Ø4
32
12
100 100
500
200
250
Ø4
32
200
B
100
200
10
500
Ø4 7
32
C
150
100
100
150
200
9
200
150
200
200
150
5
400
100
C
200
100
150
250
150
6
B
150
150
100
C
200
350
100
200
200
150
200
200
4
150
200
200
A
150
200
500
400
8
EXTERNAL TOP FLASHING
WINDOW REVEAL FOR PITCHED ROOF AIR CAVITY
2
11
80
≥50mm
200
10
10
1. Pizarra natural CUPA PIZARRAS 6. Tornillo autotaladrante INOX 11. Rejilla de ventilación
2. Pizarra de arranque 7. Escuadra metálica “punto fijo” 12. Remate metálico de coronación
3. Tornillo autotaladrante CUPACLAD® 101 8. Escuadra metálica “punto deslizante” 13. Remate metálico en vierteaguas
80
4. Perfil horizontal CUPACLAD® 101 9. Aislante 14. Remate metálico en dintel
12
CORNER
80
5. Perfil vertical “L” 50x60 10. Muro portante 15. Remate metálico en jambas
16. Chapa metálica
a b profile 50x60
77 10 6. Self-drilling stainless
16 c d steel screw
66
1 7. “Fixed point” metal
55 5 bracket
8. “Sliding point” metal
44
33
bracket
7 9. Insulation
11 10. Load bearing wall
11. Ventilated flashing
4
1. CUPA PIZARRAS natural slate 9. Insulation 12. Top metal flashing
1. Pizarra natural CUPA PIZARRAS
2. First course
2. Pizarra slate
de arranque
6. Tornillo autotaladrante INOX
7. Escuadra metálica 10. Load
“punto fijo” bearing
11. Rejilla de ventilación
wallmetálico de coronación
12. Remate
3 13. Sill metal flashing
3. Tornillo autotaladrante CUPACLAD® 101 8. Escuadra metálica “punto deslizante” 13. Remate metálico en vierteaguas
3. Self-drilling
4. Perfil horizontal CUPACLAD® 101 9. Aislante 11. Ventilated flashing 14. Remate metálico en dintel 14. Metal lintel flashing
5. Perfil vertical “L” 50x60 10. Muro portante 15. Remate metálico en jambas
CUPACLAD® 101 screw 12. Top metal flashing 16. Chapa metálica 15. Metal jambs
4. Horizontal CUPACLAD ®
101 profile 13. Sill metal flashing flashing
CUPACLAD® 101 Detalle coronación. Cubierta inclinada
5. “L” shaped vertical profile 50x60 14. Metal lintel flashing a b c d 16. Metal flashing
6. Self-drilling stainless steel screw 15. Metal jambs flashing 1
7. “Fixed point” metal bracket 16. Metal flashing
99 778 6 15 55 44 1 3
8. “Sliding point” metal bracket
10
10 8 6 15
15 15 1 3
1. Pizarra natural CUPA PIZARRAS 6. Tornillo autotaladrante INOX 11. Rejilla de ventilación 1. Pizarra natural CUPA PIZARRAS 6. Tornillo autotaladrante INOX 11. Rejilla de ventilación
2. Pizarra de arranque
3. Tornillo autotaladrante CUPACLAD® 101
7. Escuadra metálica “punto fijo”
8. Escuadra metálica “punto deslizante”
12.
13.
| 14 |
Remate metálico de coronación
Remate metálico en vierteaguas
2. Pizarra de arranque
3. Tornillo autotaladrante CUPACLAD® 101
7. Escuadra metálica “punto fijo”
8. Escuadra metálica “punto deslizante”
12.
13. CUPACLAD®|101
Remate metálico de coronación
Remate metálico en vierteaguas
15 | Remates esquina / rincón
4. Perfil horizontal CUPACLAD® 101 9. Aislante 14. Remate metálico en dintel 4. Perfil horizontal CUPACLAD® 101 9. Aislante 14. Remate metálico en dintel
5. Perfil vertical “L” 50x60 10. Muro portante 15. Remate metálico en jambas 5. Perfil vertical “L” 50x60 10. Muro portante 15. Remate metálico en jambas
16. Chapa metálica 16. Chapa metálica
CUPACLAD®
SERIE 101
Logic , Random y Parallel
| 16 | | 17 |
FIXING CUPACLAD® 201 Vanguard stainless steel clips have been designed by our
201 Vanguard
Every slate is fixed to the horizontal profile using two clips that remain par-
tially visible once the system is installed.
201
ble fixings.
SERIES
CUPACLAD® 201 series is identified by the use of stainless PATENTED SYSTEM EASE OF INSTALLATION PERFECT RESULT
steel visible fixings. The contrast between natural slate and
CUPACLAD® 201 Vanguard Our metal rails feature small The stainless steel clips have
steel gives this cladding a unique modern appearance. is a patented system develo- holes in them to mark the flanges that work just like a
ped by our R&D department exact position where the spring absorbing differences
that is designed to meet the clips should be placed. This in the thickness of the slates
highest technical require- avoids the necessity of resulting in a perfect leveled
ments of the construction drawing vertical guidelines cladding surface.
industry. and individual fixings for the
clips.
| 18 | | 19 |
CUPACLAD®
201 Vanguard
FIXING
METHOD
1 2 5 6
Fixing the metal brackets Fixing of insulation Fixing the flashings Fixing the slates with the special CUPACLAD®
201 Vanguard clips
The metal brackets are installed in alternate courses on Choose the most suitable insulation material based on the Fix a ventilated flashing at the first course of the cladding The clips are fitted to the holes in the horizontal profiles.
each side of the vertical profile. It is required to use both project requirements. and the metal flashings on “singular” points (edges, win- Each slate is supported by two clips on the lower edge
fixed point metal brackets (on the upper end of each pro- Fixing in accordance with the manufacturers recommen- dow frames, etc...). while fitted with another two on the top.
file) and brackets with a sliding point to allow for the pro- dations.
file movement.
3 4 7
Fixing the “L” shaped vertical profiles Fixing the CUPACLAD® 201 Vanguard horizon- Fixing the slates to the top of the cladding
tal profiles
At the top of the cladding when joining the gutters
or flashing it is necessary to use the 201-V top profile
Fix the vertical profiles to the metal brackets allowing at Fix the horizontal profiles with the vertical ones at each to which the slate must be fitted with two self-drilling
least 2cm for an air cavity. intersection. screws or rivets.
The vertical profiles must be perfectly level before fitting The gap between horizontal profiles when fitting a 60x30
the rest of the system components. slate must be 260 mm.
The horizontal profiles must be perfectly level as their po-
sition will dictate the final position of the slates.
| 20 | | 21 |
TECHNICAL DOSSIER | CUPACLAD® 201 Vanguard
600
VENTILATED PROFILE AND TOP FLASHING EXTERNAL 88
WINDOW REVEAL
12
99
300
5
77
6
150 300 150
14
14
260
4. L shaped 50X60 vertical profile
5. CUPACLAD® 201-V top profile
3 13
13 6. Metal bracket, “fixed point”
260
55 7. Metal bracket “sliding point”
8. Self-drilling stainless stell screws
9 66 9. Insulation
260
10. Load bearing wall
33
22
11. Ventilated profile
12. Top metal flashing
260
8
300
44
a
40
c
11
≥50mm
1. Pizarra natural CUPA PIZARRAS 6. Escuadra metálica “punto fijo” 11. Rejilla de ventilación
2. Grapa CUPACLAD® 201-V 7. Escuadra metálica “punto deslizante” 12. Remate metálico de coronación
3. Perfil horizontal CUPACLAD® 201-V 8. Tornillo autotaladrante INOX 13. Remate metálico en vierteaguas
10
10
99 66 7
7 8
8 15
15 15
15 44 22 11 33
300
H-H
5. Perfil remate superior 10. Muro portante 15.
16.
Remate metálico en jambas
Chapa metálica a b
CUPACLAD® 201 1. Pizarra natural CUPA PIZARRAS 6. Escuadra metálica “punto fijo” 11. Rejilla de ventilación
Detalles de arranque y coronación 2. Grapa CUPACLAD® 201-V 7. Escuadra metálica “punto deslizante” 12. Remate metálico de coronación
VANGUARD 3. Perfil horizontal CUPACLAD® 201-V 8. Tornillo autotaladrante INOX 13. Remate metálico en vierteaguas c d
4. Perfil vertical “L” 50x60 9. Aislante 14. Remate metálico en dintel
5. Perfil remate superior 10. Muro portante 15. Remate metálico en jambas
16. Chapa metálica CORNER FLASHINGS
5cm AIR CAVITY TOP FLASHINGCUPACLAD® 201 Recercado de ventanas
VANGUARD
FOR PITCHED ROOF
CUPACLAD® 201 a b
Detalles del sistema a b
VANGUARD 8
c d
12
CUPACLAD® 201
Remate
10 VANGUARD
5
a b
1. CUPA PIZARRAS natural slate a b c
2. CUPACLAD® 201-V Clip c d
3. Horizontal CUPACLAD® 201-V 7 6
profile 9 a b
4. L shaped 50X60 vertical profile 8
CUPACLAD® 201
Remates esquina / rincón
5. CUPACLAD® 201-V top profile c d VANGUARD
6. Metal bracket, “fixed point”
a b c d
7. Metal bracket “sliding point” 10
16
8. Self-drilling stainless stell screws
9. Insulation 5
10. Load bearing wall 1
CUPACLAD® 201
11. Ventilated profile 4 VANGUARD Remates esquina / rincón
1. Pizarra natural CUPA PIZARRAS 6. Escuadra metálica “punto fijo” 11. Rejilla de ventilación
2. Grapa CUPACLAD® 201-V 7. Escuadra metálica “punto deslizante” 12. Remate metálico de coronación
3. Perfil horizontal CUPACLAD® 201-V 8. Tornillo autotaladrante INOX 13. Remate metálico en vierteaguas
| 22 | 4. Perfil vertical “L” 50x60 9. Aislante 14. Remate metálico en dintel | 23 | CUPACLAD® 201
5. Perfil remate superior 10. Muro portante 15. Remate metálico en jambas Remates esquina / rincón
16. Chapa metálica VANGUARD
CUPACLAD® 201
Fraccionamiento de la cámara de aire
VANGUARD 1. Pizarra natural CUPA PIZARRAS 6. Escuadra metálica “punto fijo” 11. Rejilla de ventilación
CUPACLAD®
201 Vanguard
| 24 | | 25 |
TECHNICAL GLOSSARY | CUPACLAD®
a. Exclusive Cladding range, the slate for CUPACLAD® • CUPACLAD® 201-V top profile
systems For circumstances that require the use of a top section with
concealed fixing, a special top profile is needed. Made of
The CUPA PIZARRAS slate used for the CUPACLAD systems has a 7.5mm
®
aluminium alloy 6060 -T6, natural slate is then fixed by a
nominal thickness and a textured surface. It has been carefully selected for its
rivet or self-drilling screw.
technical properties to offer a flawless installation and performance.
The slate supplied for the invisible fixing systems is always pre-holed at the
required position, making its installation quicker and problem free. c. Secondary substructure
The amount of slate needed for a certain project must be always increased by • Metal brackets
5% to allow for the waste generated by the finishing details on the cladding
(corners, window sills…). Metal brackets are required for fixing the metal profile to
CUPACLAD® SYSTEMS the supporting wall. This allows adjustment of the distance
COMPONENTS between the substructure and the supporting wall to
compensate for any irregularities and allowing the use
b. Primary substructure of an insulation material behind the air cavity if specified.
a. Exclusive Cladding range, the
slate for CUPACLAD® systems b.1. CUPACLAD® 101 systems Logic, Random and Parallel Two different types of brackets must be used in order to
b. Primary substructure achieve optimal installation:
• CUPACLAD® 101 screw
b.1. CUPACLAD® 101 systems - Fixed point bracket: Should be secured to the solid
CUPACLAD® 101 series screws self-drilling have been developed to ensure structure of the building in order to resist vertical weigh
Logic, Random y Parallel optimal installation to the metallic structure. Produced in AISI 316 (A4) stainless and horizontal wind loads. Ther vertical profile is secured
steel they feature a flat head that guarantees a flawless fixing. to the fixed-point bracket using the round holes.
||| CUPACLAD® 101 screw
||| CUPACLAD® 101 • CUPACLAD® 101 horizontal profile - Sliding point brackets: Sliding point brackets secure the
horizontal profile remaining length of the vertical profile to the wall using
The CUPACLAD® 101 horizontal profile was designed by our R&D department elongated holes, to allow movement due to the thermal
b.2. CUPACLAD® 201 system to ease the installation of the slates with invisible fixings. It is made in 6060-T6 expansion of aluminium.
aluminium alloy.
Vanguard
The horizontal profiles must be perfectly level as their position defines the
||| 201 Vanguard special clip
alignment of the slates. Taking the top edge of the profile as the reference.
||| 201 Vanguard horizontal
The distance between profiles is defined for each system based on the slate
profile
size used (see page 14 and 15).
||| 201 Vanguard flashings
. Fixed point CUPACLAD® 201 metal clips are produced in AISI 316 (A4) stainless steel.
FIXED POINT SLIDING POING
. Sliding point The stainless steel clips have flanges that work just like a spring absorbing The dimension of the metal bracket will depend on the
The metal brackets, made of aluminum alloy are installed thickness of the insulating material to be installed in each
differences in the thickness of the slates resulting in a perfect level surface.
||| Vertical rail in alternate courses on either side of the profile. case and the spacing between should be specified for
• 201 Vanguard horizontal profile each project.
d. Screws.
The horizontal profile for CUPACLAD® 201 Vanguard is a patented system for The fixings used for the wall brackets must be specified
e. Air cavity. on a project basis by the manufacturer who will take into
ease of installation of our slates, manufactured from 6060-T6 aluminium alloy.
The horizontal rails must be perfectly level as their positioning will define the consideration the characteristics and detail of the suppor-
f. Insulation material. ting wall and the exposure on site.
final alignment of the slates.
g. Waterproof membrane. • Vertical L profile
The upper side of the profile features rectangular fixing slots positioned every
h. Flashings. 5cm to house the clips (screws are not required). With this method the use of
chalk marks to position the clips is no longer required. The “L” shaped 60x50x2 vertical rails manufactured from
6060-T6 profile aluminium alloy supplied in 6m lengths
i. Load bearing wall.
The gap between the vertical rails must be clarified on a
project basis taking into account the following variables
(the exposure of the site - height of the building, location,
distance from the sea….).
The vertical rails must be perfectly level before they support
all the other components of the system.
| 26 | | 27 |
TECHNICAL GLOSSARY | CUPACLAD®
d. Screws - Allow minimum of 2cm width in the ted on an individual project basis taking
CUPACLAD®
The joints between the vertical profi-
narrow areas.
- Both ventilation inlet and outlet must
allow enough air circulation. In order to
into account the varying factors (type
of building, location and exposure…). TECHNICAL ADVICE
les, the metal brackets and between
the horizontal and vertical profiles , calculate it we must take into conside- g. Waterproof Membrane
will be secured with rivets or stainless ration the dimensions of the ventilation CUPA PIZARRAS has a technical department dedicated to
steel screws A2 (Ø5,5 mm). openings at the top and bottom of the For timber buildings it is advisable to CUPACLAD®, offering its customers a consultancy service
cladding (measured in cm2 per lineal cover the supporting wall with a wa-
meter of cladding). They should be to help specify the project, ensuring the highest quality and
Horizontal profiles must be fixed to terproof membrane. It is important to
the vertical profiles in each intersec- at least: ensure the membrane is perfectly fixed commitment to provide the most appropriate solutions for
tion. In areas where two consecutive and will not cause any obstruction for every requirement.
horizontal profiles meet, the following Building Minimum correct ventilation.
must be taken into consideration: height (m) surface for
- The end of each batten must have ventilation(cm2/ml) We inspect the plans to produce a detailed specification and
its own fixing.
h. Flashings recommend the most suitable system for any individual pro-
≤ 3m 50
- Allow a gap of 3mm between both ject. Not only that, we go one step further by offering tailor
de 3 a 6m 65 Flashings can be produced in galva-
profiles.
nized steel, aluminum or zinc, and are made solutions for every requirement a certain project may
de 6 a 10m 80 used for edges, window frames and
have.
de 10 a 18m 100 other sections of the cladding.
Our technical department is also responsible for the coor-
de 18 a 24m 115
i. Load bearing wall dination of the sales, marketing and production activities to
At the first course of the cladding, the ensure the maximum quality of the material to be supplied.
opening at the inner channel must The supporting wall must ensure the
include a ventilated profile that also stability of the building. The wall must
incorporates a mesh to prevent the be sufficiently stable to support not
entry of insects & small mammals. only the weight of the cladding but
also take into account the wind loads
transmitted through the substructure.
e. Air cavity f. Insulation material
The substructure must allow for an
There are various types of insulation
air cavity between the insulation and
on the market suitable for ventilated
cladding material.
claddings. The nature and thickness of
For optimal air circulation the cavity
the insulation must be carefully calcula-
must:
| 28 | | 29 |
| 29 |
CUPACLAD®
QUALITY
One in every three slates used throughout the world is a CUPA PIZARRAS natural
slate. Our 16 quarries and 22 processing facilities combine the latest technology
with our traditional know-how and craftsmanship.
Our thorough inspection during the entire production process, from extraction to
processing prior to shipment, allows us to produce unique natural slates, recog-
nized worldwide for their quality.
| 30 | | 31 |
Ph. +44 (0) 20 3318 4455
cupaclad@cupapizarras.com
www.cupaclad.com
| 032 |