Download as pdf
Download as pdf
You are on page 1of 6
Produkte A TUVRheinland® Seite 1 von 41 Pritbericht-nr Autrags-Nr. Prifberiehte 0285122 001 Auttrags 168129064 Page total Kandon-ReferonzNr ‘utragedatum Client Reference No. 442985 Order date: 18.07.2019 Aurtraggober Shanghai Chnt Power Systems Go Ltd Prifgegenstand: rid-connectec Inverter Test item: Grice ted PV Invert Bezelchnung /Typ-Nr Bezechnung ITYPNF cps scaa0KTL-TISA GPS SCATSKTLTSA ‘Auftrags-nnalt Order content. AK certificate Prifgrundlage: ‘EEE Sta 1547: 2008 Testspecitaton: IEEE Sid 1847.4: 2008 Wareneingangedatum: Date of receipt: 18.07.2019 Prifmustor Nr: GPS SCASOKTL-TISA” 3016-808 = Test samp No GPS SCABBKTLTISA. 85081908 Eg } Pratzettraum: Prieta: 18.07,2019.31.07 2018 ro Ortder Prafung: CIC Southem Electronic Product Place of testing: Testing(Shenzhen) Co., Ltd. g |; | Prflaboratorum: Testing laboratory ‘TOV Rheinland (Shanghai) Co.,Ltd, Prifergebris" Test result*: Pass geprli von /losoa by Kontron von /voviowea by ers Tope sn0s2019 Xun Yw PE “Xun 7992010 Bowen Dong/ Reviewer_/ ~~ ree nte en one Tem ee an fe” Aare Poms Somme Gee” Rome Boocr Soman Sonstiges / Other None Zustand des Prifgogorstandes bel Anlieferung’Prfmustervlltandig und unbeschagt Conattn othe test fem at delivery Test tem compete and undamaged gaia op Fam Smpiton Palbindon) FohsoasrovneogPatnndan) Ns ligenk Tetaygeed EeqedSanty Pass passed am ws speccston(s) Fa od am rst species Dieser Priifbericht bezieht sich nur auf das o 9. Prifmuster und darf ohne Genehmigung der Prifstelle nicht auszugsweise vervielfatigt werden. Dieser Bericht berechtigt nicht zur Verwendung eines Priifzeichens. This tost report ony relates tothe a. m. test sample. Without permission ofthe test center this test report isnot permitted to be ‘duplicated in extrac. This test report does not entile fo carry any ast mark TU Rheintand (Shanghai) Co.,Ltd. TOV Rheinland Bling, No. 177, Lane 777, West Guangenong Road, Zhaboi Dist, Shanghs! ‘200072, P-R. China Report No.: 50285122 001 A TUVRheinland” Precisely Right Test item particulars Description. Grid-connected PV Inverter Trademark ane OuE Factory ZHEJIANG CHINT POWER SYSTEMS CO., LTD No. 379 Ziyu Road, Nanhu District, Jiaxing, Zhejiang 314008, China Model andlor type reference (CPS SCASOKTL-TISA,CPS SCA36KTL-TISA Rating ‘See below Installation mode Fixed Software/Fimware tested within the unit ‘Software: 600101 Hardware CPS SCA3OKTL-TISA:9511-3015 CPS SCA36KTL-TISA‘9511-3604 Relative humidity range. 4100% Enclosure index / type. NA Equipment mobility No Mass of equipment (Kg) 67 ‘Overall size (WxDxH) ‘See below Alttude(m) <4000 Possible test case verdicts: = test case does not apply to the test object NIA = test object does meet the requirement, P (Pass) = test object does not meet the requirement. F Fail) Testing Date(s) of performance of tests, 18.07.2019-31.07.2019 Place of testing. ‘GCIC Southern Electronic Produet Testing(Shenzhen) Co., Ltd Rrv01741.002 Page 2ot4t Revision 0.1 A TUVRheinland” Precisely Right. Report No.: 50285122 001 General product information: The equipment with model CPS SCA3OKTL-T/SA,CPS SCA36KTL-T/SA are three phase PV grid inverters ‘which willbe installed and connected to the grid network after installation. In final installation the equipment shall be fixed to suitable manner as specified in the installation instruction. It contains fiers for smoothing the output voltage and for EMC, switching and control circuits. Electronic circuits are mounted on a number of PCBs interconnected by appropriate connectors and wires. Power board including electronics components are mounted on the heat sink to earthing by metal screw and spring washer. There is a RS485 communication port which is connected to the upper computer or network to monitor the status of the inverter by proprietary software. AC output connected to grid directly and Protective Earthing is provided by dedicated earthing terminal. Grid is protected by a combination with a two relays in series for each phase conductor as redundant build {or ensuring the inverter disconnected independently from gird when a relay was fault. During fauit condition defined in this standard, after the DSP receives the abnormal signal from the relevant protective detection circut, the relays will operate to disconnect the PV inverter active lines from grid automatically ‘The master DSP and slaver DSP have capacity independent disconnected from gird, when any grid faults ‘were happened ‘The maximum ambient temperature permitted by the manufacturer's specication is 60°C and derate the ‘output power from 45°C. Models difference: ‘The models SE CPS SCASOKTL-T/SA and CPS SCAS6KTL-T/SA are same as the construction, hardware and software, expect the components desctribed as below and output power is dference adjusted by software, Medel Deferent —-—_ CPS SCA3OKTL-T/SA (CPS SCA36KTL-T/SA Input stings 31322 3131393 Rrv01741.002 Page 3of4t Revision 0.1 Report No.: 50285122 001 A TUVRheinland” Precisely Right Model list (CPS SCAS6KTLTISA (CPS SCA30KTLTISA VMAX PV [Vee] 800 Isc PVIA] 42142142142. 42142128128 MPP Voltage Range | VMPP [vec}| 200-750 PVINPUT Max. Input Current IMAX [A] 39/99/39/33 39/93/22/22 Overvoltage Category(OVe) Rated Output Voltage Ur {Vac} 3N~+PE, 2 108/220/240 Rated Output Frequency Frere (Hz) 50/60 Rated Output Power Pe [kW] 32.4134.5137.5 27.5129131.5 Rated Output Current Imax (A) Grid AC OUTPUT 90 78 Max. Output Current Imax (A) 2 83 Power Factor cose [A] O.8Leading ~ 0.8 lagging Type of inverter Non-transformer Type of NS Protection integrated = _ |Protecive Glass l & | Enclosure Protection Sj) IP8s Z | Operating B | Temperature Range 25 10.60 (> 45 deratng) 6 {rei 8 Altade il 4000 Size (WxtxD) [mn 855mm565mmx27Smm Weight ka) 7 Note Block Diagram Tests were performed on model CPS SCA36KTL-T/SA and additional tests were performed on model CPS SCA3OKTL-TISA, Test result cover all models, All tests are consider on rated voltage 220V(L-L) and frequency 60Hz. Rrv01741.002 Page dot4t Revision 0.1 Report No.: 50285122 001 A TUVRheinland® Precisely Right. Nameplate: CHNT Fone caterer Na a en Secchi | Pte Mt aera eee chown a A® mA AO QS as i mo A = @=i ® 1547.1 1547.4 147.4 147.4 1847.4 1547.41 1547.1 147.4 52 53 54 56 87 59 5.1 5A ‘Summary of Testing: Response to abnormal voltage conditions Response to abnormal frequency conditions ‘Synchronization De Injection Limitation Unintentional istanding Open Phase 0 1 Reconnection time Harmonics Rrv01741.002 Page sof4t Revision 0.1 A TUVRheinland” Precisely Right. Report No.: 50285122 001 8 Litton of BG injection foriverer without intercomectonTranstommers | ce oxo | page, | Eo SUbHE aed oma ae Te | Phase cunt | factor | Votage | BC current | rmponont | component (%). Limit (%) aw [8 | a9 | ow | aso | ono | 018 05 | me | 090 | sera | ons | an 05 A [se | eee | waras | oan | oar 05 com [® | 504 | 000 | verse | om) 02s 05 c | se7 | 09 | serv | ones | are 05 A [ses | ae | wares | on | ove 05 rox [8 | ese | eee | varer| came | om 05 A [ss | ace | vena | oma | 024 05 Value ‘o0%P eur aur Phase A B c A B c A B c wnt Vara Teta [R7OE HRS | ese | Hee aes | ESS ae Rrv01741.002 Page 33 of 41 Revision 0.1

You might also like