1. General
1.1 This specification covers the requirements for the supply of dry core, single-mode
optical fiber cables.
1.2 This single mode optical fiber cable shall comply with the requirements of this
specification and ITU-T G.652D.

2. Fiber characteristics
The optical, geometrical, mechanical and environmental performance of the optical fiber shall
be in accordance with tables 2.1.
Table 2.1 G.652D fiber characteristics
G.652D fiber characteristics
Optics specifications
@1310nm ≤0.360dB/km
Attenuation @1383nm(after hydrogen aging) ≤0.360dB/km
@1550nm ≤0.250dB/km
@1285nm~1340nm -3.5ps/(nm·km)~3.5ps/(nm·km)
Dispersion @1550nm ≤18ps/(nm·km)
@1625nm ≤22ps/(nm·km)
Zero-Dispersion wavelength 1300nm~1324nm
Zero-Dispersion slope ≤0.092ps/(nm2·km)
Mode field diameter (MFD) at 1310nm 9.2±0.4μm
Mode field diameter (MFD) at 1550nm 10.4±0.5μm
Max. for fiber on the reel 0.10ps/km1/2
PMD
PMDQ (Link) 0.04ps/km1/2
Cable cutoff wavelength λcc(nm) ≤1260nm
Geometrical characteristics
Cladding diameter 125±1.0μm
Cladding non-circularity ≤0.7%
Core/cladding concentricity error ≤0.5μm
Fiber diameter with coating (uncolored) 242±5μm
Cladding/coating concentricity error ≤12.0μm
Curl ≥4m
Mechanical characteristics
Proof stress ≥0.69GPa(100kpsi)
Coating strip force (typical value) 1.4N
Dynamic stress corrosion susceptibility parameter (typical value) ≥20
Macrobend loss Φ60mm,100 turns ≤0.05dB
at 1550nm Φ32mm,1turn ≤0.05dB
Environmental characteristics (at 1310nm & 1550nm)
Temperature induced attenuation(-60~+85℃) ≤0.05dB/km
Dry heat induced attenuation (85℃±2℃, 30 days) ≤0.05dB/km
Water immersion induced attenuation (23℃±2℃, 30 days) ≤0.05dB/km
Damp heat induced attenuation (85℃±2℃, RH85%, 30 days) ≤0.05dB/km

13

433
FiberHome Technologies
3 PHYSICAL, MECHANICAL, ENVIRONMENTAL, PERFORMANCE AND TESTS

3.1 Mechanical and Environmental Performance of the Cable


The mechanical and environmental performance of the cable shall be in accordance with Table
3.1 below. Unless otherwise specified, all attenuation measurements required in this section
shall be performed at 1550nm for single mode fiber.
Table 3.1 The Mechanical and Environmental Performance of the Cable

Item Test Method Test Conditions Acceptance Criteria


L  100 m
Load:
144080000011:2700N
144080000012:2700N
144080000013:2700N
144080000008:2700N
Additional attenuation≤0.15 dB
IEC60794-1-2- 144080000009:5000N
Tensile Strength No visible damage to the surface
E1 144080000005:2400N
of out sheath
144080000025:2400N
144080000007:3600N
144080000026:4500N
144080000010:5000N
144080000020:5000N
Time: 1 minute
Load:1000N Additional attenuation≤0.15dB
IEC60794-1-2-
Crush Resistance Time: 1 minute No visible damage to the surface
E3
Length: 100 mm of out sheath
The impact of weight:
≥450g Additional attenuation≤0.15dB
Impact IEC60794-1-2-
Weight high: 1m No visible damage to the surface
Resistance E4
3 point , 5 times per of out sheath
point
Load: 150 N
Tests = 25 cycles Additional attenuation≤0.15dB
Repeated IEC60794-1-2-
R= 30 x Ø cable No visible damage to the surface
bending E6
Each cycle  2 sec. of out sheath
L =1.0 m
The test length =1m, Additional attenuation≤0.15dB
IEC60794-1-2-
Torsion ±180 degree,10 cycles, No visible damage to the surface
E7
Test weight 150N of out sheath

14

434
FiberHome Technologies
displayed in tables 5.1 for the loose buffer tubes and 5.2 for the individual fibers.

Item Test Method Test Conditions Acceptance Criteria

Operating Temperature:
-30 º C to +70 º C
Temperature IEC60794-1-2-
Cycle time:24h Additional attenuation ≤0.15 dB
cycling F1
Cycle:2
Cable length:  1000 m

12h
70℃

-30℃

12h
At 20±5 ℃ ,1m water
Water penetration IEC60794-1-2- column applied to one of
No water penetration
Test F5 1m cable after 24h,no
water penetration

3.2 Operating Condition


Item Range

Installation -30℃ to +70℃

Temperature Operation -30℃ to +70℃

Transportation -30℃ to +70℃

Other cable constructuion standards


EIA/TIA-495 GR-20
IEC 793-1 IEC 794-1
ISO 9001 ISO 14001 ISO 27001
15

435
FiberHome Technologies
displayed in tables 5.1 for the loose buffer tubes and 5.2 for the individual fibers.
OHSAS 18001
SA8000
TL9000

4 Packing and Sheath Marking

4.1 Cable and Length Marking


The sheath shall be marked with white characters at intervals of one meter with following
information. Other marking is also available if requested by customer.

**** FIBERHOME GYFY **FO G652D 2019 DRUM NO. METERS

4.2 Cable Packing

Standard length of cable shall be 4,000m per reel with a tolerance of -3%/+3%. Other cable
lengths are also available if requested by customer.

Both ends of the cable shall be sealed with suitable plastic caps to prevent the entry of
moisture during shipping, handling and storage.

The cable ends shall be securely fastened to the reel to prevent the cable from becoming loose
in transit or during placing operations.

The inner end of the cable is housed into a slot on the side of the reel without extra cable
length for testing.

Circumference battens or wood-fiber board shall be secured with steel bands to protect the
cable during normal handling and shipping.

4.4 Cable Reel

4.4.1 Details given below shall be distinctly marked with a weather-proof material on
both outer sides of the reel flange:
1) Purchaser’s name
2) Reel number
3) Name of the manufacturer
4) Year of manufacture
5) Arrow showing the direction the drum shall be rolled
6) Purchase order number

4.4.2 Other shipping mark is also available if requested by customer.


16

436
FiberHome Technologies
displayed in tables 5.1 for the loose buffer tubes and 5.2 for the individual fibers.

4.4.3 The cable shall be shipped on reels designed to prevent damage to the cable
during shipment and installation.

4.4.4 The arbor holes provided in the reels shall be approximately 105 mm with a
wood or steel hub in the arbor hole (in lieu of fiberboard).

5 Fiber and Loose Buffer Tube Identification (TIA 598A)

The color code of the loose buffer tubes and the individual fibers within each loose buffer is
Table 5.1. The Color Code of the Loose Buffer Tubes
According to the number of loose tubes, color is arranged sequentially.
Position Color
1 Blue
2 Orange
3 Green
4 Brown
5 Slate (Grey)
6 White
7 Red
8 Black
9 Yellow
10 Violet
11 Rose (Pink)
12 Aqua (Light Blue/Cyan)

Table 5.2. The Color Code of Individual Fibers

Position Color
1 Blue
2 Orange
3 Green
4 Brown
5 Slate (Grey)
6 White
7 Red
8 Black
9 Yellow
10 Violet
11 Rose (Pink)
12 Aqua (Light Blue/Cyan)

17

437
FiberHome Technologies
displayed in tables 5.1 for the loose buffer tubes and 5.2 for the individual fibers.
6 Data form

Test data include attenuation values of each of the fibers in 1310nm and 1550nm , test
certificates and quality measurements will be sent by paper and digital form.