DRAFT_Programming Notification Appliances_A1
DRAFT_Programming Notification Appliances_A1
Notification Appliances
Begin
2
Programming Notification Appliances
Programming Notification Appliances
This Job Aid will assist you in programming Notification Appliances by type and functionality.
**If you require additional information on how to navigate this document, click here for an overview.
3
TrueAlert ES 4900 Series Addressable Multi-Candela Notification Appliance Pg.
Technical Publications: 579-1031, 579-1032, 579-1033, 579-1034
Step 2: Operation
Click the appropriate link below for the Desired Operation
. "Alert" or "Other" Horn and Strobe operation (requires Custom Control programming)
4
TrueAlert ES Addressable Indoor Multi-Tone Notification Appliance
Technical Publications: 579-1152, 579-1156
Step 2: Operation
Click the appropriate link below for the Desired Operation
• "Alert" or "Other" Horn and Strobe operation (requires Custom Control programming)
5
TrueAlert ES Addressable Emergency Indoor Notification Appliance
Technical Publications: 579-1052
Step 2: Operation
Click the appropriate link below for the Desired Operation
• "Alert" or "Other" Horn and Strobe operation (requires Custom Control programming)
6
TrueAlert ES 5900 Series Addressable Audible Notification Appliance
Technical Publications: 579-1162, 579-1199, 579-1200
Step 2: Operation
Click the appropriate link below for the Desired Operation
• "Alert" or "Other" Horn and Strobe operation (requires Custom Control programming)
7
TrueAlert ES 4900 Series Addressable Notification Appliance Pg. 18 Return to Step 2
PANEL TAB
System Options screen, Addressable Appliance Preferred Defaults box is where the system default operations for horns
and strobes are specified.
.
The Panel tab is where you select the required candela
setting and the GENERAL EVAC Tone to be played on
alarm.
HARDWARE TAB
8
TrueAlert ES Addressable Indoor Multi-Tone Notification Appliance Pg. 19 Return to Step 2
HARDWARE TAB
9
TrueAlert ES Addressable Indoor Multi-Tone Notification Appliance Pg. 20 Return to Step 2
HARDWARE TAB
10
TrueAlert ES Addressable Emergency Indoor Notification Appliance Pg. 21 Return to Step 2
PANEL TAB
Panel tab, System Options screen, Addressable Appliance Preferred Defaults box are where the system default operations for
the strobes are specified.
Candela Choices
15cd
20cd
30cd
75cd
110cd
. 135cd
185cd
The Panel tab is where you select the desired WP75cd
candela rating. WP185cd
Hardware
HARDWARE TAB
11
TrueAlert ES Addressable Emergency Indoor Notification Appliance Pg. 22 Return to Step 2
The Panel tab is where you select the desired If manual selection is required, set the Appliance candela
candela rating flag to select the desired candela setting. The candela
values listed on the Appliance are for clear lenses only.
HARDWARE TAB
12
TrueAlert ES 5900 Series Addressable Notification Appliance Pg. 23 Return to Step 2
PANEL TAB
Panel tab, System Options screen, Addressable Appliance
Preferred Defaults box is where the system default operations
for horns and strobes are specified.
HARDWARE TAB
13
TrueAlert ES 5900 Series Addressable Notification Appliance Pg. 24 Return to Step 2
PANEL TAB
Panel tab, System Options screen, Addressable Appliance Preferred Defaults box is where the system default operations for horns
and strobes are specified.
Candela Choices General Evacuation and Alert Tone Choices
15cd Broadband
20cd 520Hz
. 30cd Bell
75cd Slow Whoop
110cd Siren
135cd HiLo
The Panel tab is where you select the desired candela 185cd Chime
rating and required GENERAL EVAC Tone to be WP75cd Hardware
played on alarm. WP185cd
Hardware
HARDWARE TAB
14
TrueAlert ES 5900 Series Addressable Notification Appliance Pg. 25 Return to Step 2
PANEL TAB
Panel tab, System Options screen, Addressable Appliance Preferred Defaults box is where the system default operations for
horns and strobes are specified.
The Panel tab is where you select the desired candela rating and required
GENERAL EVAC Tone to be played on alarm.
HARDWARE TAB Selecting ALERT as the Operation in the Hardware tab auto populates SIG902
(TrueAlert Zone 3 All Alert Devices) with the Appliance. However, SIG902 is not
In the Hardware tab, set as follows: referenced in any default programming, so Custom Control must be written.
* Device Operations to GENERAL EVAC When OTHER is selected in the Hardware tab as the operation, the Appliance
* Tone to Broadband does not auto populate any of the default TrueAlert Zones. A custom TrueAlert
* Coding type to ONSTEADY. Zone will need to be created for this device and Custom Control must be written.
To have the strobe operate on all Alert Appliances SIG902 when a Priority 2 or
Supervisory condition is reported, enter the following Custom Control equation:
[INPUTS]
STATUS ON
A122 | ANALOG | ANALOG | NUMBER OF SYSTEM PRIORITY 2 ALARMS
OR STATUS ON
A1 | ANALOG | ANALOG | NUMBER OF SYSTEM SUPERVISORIES
[END INPUTS]
[OUTPUTS]
HOLD ON PRI=9,9
SIG902 | SIGB | SIGNAL | TRUEALERT ZONE 3 - ALL ALERT DEVICES
[END OUTPUTS]
15
TrueAlert ES 4900 Series Addressable Notification Appliance Pg. 26 Return to Step 2
PANEL TAB
IMPORTANT: The Alert Tone
is selected in the Panel tab,
however full functionality is
only available when Multi-
Tone Appliances are used.
HARDWARE TAB
Address Switch 8 set to ON, indicating it will be programmed as an "Alert" or "Other" Appliance.
16
TrueAlert ES Addressable Indoor Multi-Tone Notification Appliance Pg. 27 Return to Step 2
PANEL TAB
The ALERT Tone is selected in the Panel tab, it will be the tone played for
all appliances programmed as ALERT or OTHER.
HARDWARE TAB
The operation must be set to ALERT or OTHER in the Hardware tab. The Hardware tab Tone and Coding Type selections
determine the Appliance operation. Selecting a Tone for a device in the Hardware tab will overrule the Panel tab selection for
this Appliance.
Selecting ALERT as the Operation in the Hardware tab auto populates SIG902 (TrueAlert
Zone 3 All Alert Devices) with the Appliance, but SIG902 is not referenced in any default
programming so Custom Control must be written. When OTHER is selected in the
Hardware tab as the operation, the Appliance does not auto populate any of the default
TrueAlert Zones. A custom TrueAlert Zone will need to be created for this device and
Custom Control must be written.
To play the Hardware Coding Type on all Alert appliances SIG902, when a Priority 2 or
Supervisory condition is reported, enter the following Custom Control equation:
[INPUTS]
STATUS ON
A122 | ANALOG | ANALOG | NUMBER OF SYSTEM PRIORITY 2 ALARMS
OR STATUS ON
A1 | ANALOG | ANALOG | NUMBER OF SYSTEM SUPERVISORIES
[END INPUTS]
[OUTPUTS]
HOLD ON PRI=9,9
SIG902 | SIGB | SIGNAL | TRUEALERT ZONE 3 - ALL ALERT DEVICES
[END OUTPUTS]
Address Switch 8 set to ON, indicating it will be programmed as an "Alert" or "Other" Appliance.
17
TrueAlert ES Addressable Emergency Indoor Notification Appliance Pg. 28 Return to Step 2
PANEL TAB
Program Panel tab, Hardware tab, and Appliance The candela rating is selected in the Panel tab.
HARDWARE TAB
Selecting ALERT in the Hardware tab as the Operation auto populates SIG902
(TrueAlert Zone 3 All Alert Devices) with the Appliance, but SIG902 is not
referenced in any default programming so Custom Control must be written.
When OTHER is selected in the Hardware tab as the operation, the Appliance
does not auto populate any of the default TrueAlert Zones. A custom TrueAlert
Zone will need to be created for this device and Custom Control must be
written.
To have the strobe operate on all Alert appliances SIG902 when a Priority 2 or Supervisory condition is reported, enter the
following Custom Control equation:
[INPUTS]
STATUS ON
A122 | ANALOG | ANALOG | NUMBER OF SYSTEM PRIORITY 2 ALARMS
OR STATUS ON
A1 | ANALOG | ANALOG | NUMBER OF SYSTEM SUPERVISORIES
[END INPUTS]
[OUTPUTS]
HOLD ON PRI=9,9
SIG902 | SIGB | SIGNAL | TRUEALERT ZONE 3 - ALL ALERT DEVICES
[END OUTPUTS]
Address Switch 8 set to ON, indicating it will be programmed as an "Alert" or "Other" Appliance.
18
TrueAlert ES 4900 Series Addressable Notification Appliance Pg. 29 Return to Step 2
HARDWARE TAB
Device Coding
Horn Type Tone Type
Operation
General Evac Broadband Broadband System Default
Temporal
March 20
March 60
March 120
On Steady
Temporal 4
**Address Switch 8 OFF indicates that the appliance is viewed by the system
as an‘Alarm’ Appliance
19
TrueAlert ES Non-Addressable Multi-Tone Notification Appliance Pg. 30 Return to Step 2
PANEL TAB
.
Switch Package
Switch 1 OFF is for Local Control, the selected tone (identified on Switches 5, 6, and 7) will play when power is applied. When
Switch 1 is OFF, you will program the NAC circuit wired to this device as a conventional hardwired signal circuit choosing a point
type of SSIGNAL, RSIGNAL, or SIGNAL. This device could also be wired to any competitor's fire alarm panel that provides a
typical reverse polarity NAC circuit.
Switch 1 ON says that the panel selected tone plays when commanded by the panel per SmartSync cadence. The point type for
the device wired to this circuit would be programmed as SQALERT or QALERT.
Switch 2 OFF means the output volume will be high, ON for low.
Switch 3 OFF selects SmartSync 60bpm. ON selects SmartSync 20bpm, a Canadian requirement.
American versions of these units play MARCHTIME 60bpm no matter how Switch 3 is configured.
Switch 4 is always set to ON....setting this Switch to OFF will disable the horn.
20
Click the Appropriate Appliance Category :
Addressable
TrueAlert ES Addressable Multi-Candela Indoor Notification Appliance
TrueAlert ES Addressable UL Listed Multi-Candela Weatherproof Notification Appliance
TrueAlert ES Addressable ULC Listed Multi-Candela Weatherproof Notification Appliances
TrueAlert ES Addressable Indoor A/O Notification Appliance
TrueAlert ES Addressable Emergency Indoor Notification Appliance
TrueAlert ES Addressable Indoor Multi-Tone Notification Appliance
TrueAlert ES Addressable Multi-Candela, Multi-Tone Indoor Notification Appliance
TrueAlert ES Addressable Multi-Candela Indoor LED Notification Appliance
TrueAlert ES Addressable Weatherproof Audible Notification Appliance
TrueAlert ES Addressable Indoor Audible Notification Appliance
Non-Addressable
TrueAlert ES Indoor Non-Addressable Multi-Tone Notification Appliance
TrueAlert ES Non-Addressable Multi-Candela, Multi-Tone Indoor Notification Appliance
21
Index by PID
22
TrueAlert ES Non-Addressable Multi-Tone Notification Appliance Pg. 30 Return to Step 3