Professional Documents
Culture Documents
2007-01-1393
2007-01-1393
SAE TECHNICAL
PAPER SERIES 2007-01-1393
400 Commonwealth Drive, Warrendale, PA 15096-0001 U.S.A. Tel: (724) 776-4841 Fax: (724) 776-0790 Web: www.sae.org
Downloaded from SAE International by University of Minnesota, Tuesday, July 31, 2018
By mandate of the Engineering Meetings Board, this paper has been approved for SAE publication upon
completion of a peer review process by a minimum of three (3) industry experts under the supervision of
the session organizer.
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or
transmitted, in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise,
without the prior written permission of SAE.
SAE Permissions
400 Commonwealth Drive
Warrendale, PA 15096-0001-USA
Email: permissions@sae.org
Fax: 724-776-3036
Tel: 724-772-4028
ISSN 0148-7191
Copyright © 2007 SAE International
Positions and opinions advanced in this paper are those of the author(s) and not necessarily those of SAE.
The author is solely responsible for the content of the paper. A process is available by which discussions
will be printed with the paper if it is published in SAE Transactions.
Persons wishing to submit papers to be considered for presentation or publication by SAE should send the
manuscript or a 300 word abstract of a proposed manuscript to: Secretary, Engineering Meetings Board, SAE.
Printed in USA
Downloaded from SAE International by University of Minnesota, Tuesday, July 31, 2018
2007-01-1393
600
Engine Off
Man 2
500
Man 1
400
Temperature (ºC)
Cat 1
Cat 3
300
Cat 2
200
Ex 1
Ex 2
Oil
100
0
00:00 05:00 10:00 15:00 20:00 25:00 30:00 35:00 40:00
Time (min:sec)
The removal of forced convective cooling, when the along the circumference defined by a cross sectional
vehicles were stopped, was offered as an initial plane perpendicular to the axis of the pipe. The
explanation for the phenomenon observed. However, thermocouples were installed on a new section of
upon further consideration the clamps and the exhaust pipe prior to being installed in the vehicle. The
thermocouple housing were believed to be acting as thermocouples and their attachment method are listed in
cooling fins, thereby reducing the observed temperature Table 2 and their placement is shown in Figure 2.
at the thermocouple bead location while the vehicles
were in motion. When the vehicles were stopped the Table 2: Thermocouple types and attachment methods.
added cooling effect from the clamp was reduced and
the temperature increased to be closer to the Thermocouple Type Thermocouple Attachment
surrounding exhaust component surface temperature. Make/Model Method
Surface Temperature Omega Hi Clamped
Discussions with expert vehicle fire investigators (same as Temperature XCIB
suggested that the increase in temperature was a recommended for Style 4
physical phenomenon that may occur when an engine is initial testing)
turned off. A reference to this phenomenon was even Thin Film Surface Omega Cement-on Cemented
found in the National Fire Protection Association’s guide Temperature Style 2, CO2-K
for fire investigation [Ref. 2]. It was also suggested that Bead Omega Ready Brazed
Bead Made Cemented
thermocouple attachment method may also have been 5SRTC-GG-K
responsible for temperature increase. Surface Temperature Omega Weld Pad Welded
Probe Probe PDR
Complete results for the eleven measurement locations
[Ref. 7] are not presented due to the anomaly and the
associated uncertainty in the measured temperature
values. In an effort to investigate the anomaly and the
possible role of the thermocouple, an additional test on
one vehicle was undertaken to evaluate thermocouple
types and attachment methods. The results of the
testing are discussed herein.
600
Engine Off
550
500
450
Brazed Bead TC
Temperature (°C)
400
Cement On TC
300 Weld On TC
250
200 Clamp On TC
150
100
0 200 400 600 800 1000 1200 1400
Time (seconds)
600
Engine Off
550
500
450
Cement On TC Brazed Bead TC
Temperature (°C)
400
Cement On Bead TC
350
Weld On TC
300
250
Clamp On TC
200
150
100
0 200 400 600 800 1000 1200 1400
Time (seconds)
600
Brazed Bead TC
550
Cement On TC
500
Cement On Bead TC
450
Weld On TC
Temperature (°C)
400
350
300
250
Clamp On TC
200
150
Engine Off
100
0 200 400 600 800 1000 1200 1400
Time (seconds)
600
Brazed Bead TC
550
Cement On TC
500
Cement On Bead TC
450
Temperature (°C)
400 Weld On TC
350
300
Clamp On TC
250
200
150
Engine Off
100
0 200 400 600 800 1000 1200 1400
Time (seconds)
The undulations in the temperature measurements seen a range of almost 100 °C at location A. A possible
in the uphill driving temperature time histories (Figure 5 explanation for the difference in the temperature ranges
and Figure 6) are directly linked to ascending or measured at the two locations may be due to the
descending of the hill as previously described in the test turbulence of the exhaust gas flow within the pipe. At
procedure. location A the exhaust gases in the four manifold pipes
have traveled different distances from the exhaust
The brazed-on thermocouple bead registered the highest valves, thereby producing an uneven temperature
surface temperature measurements at both distribution. Additionally, the exhaust manifold clamp
measurement locations and under both driving introduced an uneven thermal mass distribution (see
conditions. The clamp-on surface temperature Figure 2) at location A which was less exposed to airflow
thermocouple measured the lowest. However, the than location B. At location B, the exhaust gas
temperatures recorded by the brazed-on, the cemented- temperature has stabilized after having passed through
thin-film and the cemented-bead thermocouples at the first catalytic converter. The smaller differences
location B were within approximately 30 °C compared to observed in this location could be due to the differences
Downloaded from SAE International by University of Minnesota, Tuesday, July 31, 2018
in convective cooling occurring around the circumference associated with the thermocouples sheathing or clamp
of the pipe at the measurement location. may be responsible for the 75 °C to 175 °C lower
temperatures measured when compared to the
The clamped-on surface temperature thermocouple and brazed-on-bead thermocouple.
the welded-on surface temperature probe had noticeably
slower response times than the other thermocouples Temperature increases that occurred after the engine
used. This is likely due to the thermal mass associated was turned off were observed with the clamped-on
with these thermocouples’ exterior sheathing which may thermocouple, the welded surface temperature probe
have acted like heat sinks delaying the discernment of and the cemented thermocouple bead. These increases
temperature changes. Diminished thermal conductivity are summarized in Table 3 for the different driving
between the pipe surface and the clamped thermocouple conditions and measurement locations.
would have also contributed to the slower response time
of the clamped-on thermocouple. This, in conjunction
with the additional forced convective cooling that may be
Table 3: Summary of observed temperature increases after the vehicle engine was turned off.
Test TC Type Temperature at Peak Temp Temperature Time of Peak After
Condition Engine Shut-off (°C) Increase Engine Turned Off (s)
(°C) (°C)
Clamped 215 249 34 60
Level Road Cemented Thin Film 377 377 0 0
TC location Brazed 403 403 0 0
A Cemented Bead 342 353 11 15
Welded Probe 292 326 34 25
Clamped 225 277 52 120
Level Road Cemented Thin Film 399 399 0 0
TC location Brazed 410 410 0 0
B Cemented Bead 394 394 0 0
Welded Probe 327 356 29 30
Clamped 313 352 39 50
Uphill Cemented Thin Film 499 499 0 0
TC location Brazed 526 526 0 0
A Cemented Bead 473 475 2 5
Welded Probe 441 442 1 5
Clamped 313 341 28 50
Uphill Cemented Thin Film 514 514 0 0
TC location Brazed 522 522 0 0
B Cemented Bead 498 498 0 0
Welded Probe 447 459 12 15
The cemented bead thermocouple at location A exhibited were never actually reached by the clamped-on or
a comparatively small temperature increase in two welded probe thermocouples. Therefore, both these
instances. As indicated previously, there appeared to be thermocouples are conservative in their measurement of
a temperature gradient around the circumference of the the exhaust surface temperatures and indicate that the
pipe at this location. When the engine was turned off the measurements on the initial four vehicles under
immediate response would have been for the local low represent the peak temperatures that were attained.
temperature location to equalize with an adjacent higher
temperature. This may have resulted in a brief After the peak temperatures were reached the
temperature increase. At location B, where the thermocouples all cooled at approximately the same
temperature gradient was not as apparent, such a rate.
temperature equalization effect would not have been as
apparent. Regardless, if the hottest location is selected SUMMARY
an increase in temperature would not be expected.
Following a collision, hot surfaces may be potential
The additional forced convective cooling associated with ignition sources for spilled engine compartment fluids
the clamped-on and the welded probe thermocouple such as engine oil, transmission oil, brake fluid, coolant,
sheathing likely contributed to the lower temperature power steering and gasoline. In previous research,
measurements. With the vehicle stopped and the engine exhaust system temperatures of four vehicles were
turned off the forced convective cooling would cease, measured at eleven locations under several driving
allowing the measured temperature to increase and conditions [Ref. 7].
approach the bead and thin-film thermocouple
measurements. The higher temperatures, however,
Downloaded from SAE International by University of Minnesota, Tuesday, July 31, 2018
The recorded surface temperatures were measured In consideration of possible thermal gradients around the
while driving and were continued after the vehicles were circumference of the pipe at the measurement locations,
pulled off to the side of the road and the engine turned the brazed-thermocouple bead and the cemented-on thin
off. This simulated a collision in which the vehicle may film thermocouple produced similar results. However,
have come to a sudden halt. the thin film thermocouple required more effort and
preparation to install. Generally, the brazed-on
Under both the level road and the uphill driving thermocouple bead would be recommended for further
conditions a phenomenon was observed in which the measurements under similar conditions to those
measured temperatures initially increased after the discussed.
engines were turned off.
ACKNOWLEDGMENTS
To investigate the observed increases in temperature
measurements after the engines were turned off, The authors would like to acknowledge the funding and
additional tests were conducted on a single vehicle to support provided by the Motor Vehicle Fire Research
determine the effect of 5 different thermocouple types Institute in conducting the under hood temperature
and attachment methods. Brazed-on, welded-on, measurement study.
clamped-on and cemented-on thermocouple attachment
methods were employed to measured surface REFERENCES
temperatures at two locations on the exhaust system
during level road and uphill driving at 60 mph (96 km/h).
1. Colwell, J. D. and Reza, A., “Hot Surface Ignition of
At both measurement locations and under both driving
Automotive and Aviation Fluids”, Fire Technology,
conditions the brazed-on thermocouple bead registered
Vol. 41, pg. 105-123, 2005.
the highest temperatures whereas the clamp-on
thermocouple, similar to that used in the initial testing 2. “NFPA 921: Guide for Fire and Explosion
registered the lowest temperatures. Investigations”, National Fire Protection Association,
2004 Edition.
The two thermocouples with higher thermal mass 3. Santrock, J., Kononen, D. W.,”Project B.10 – Study
associated with their construction, namely the clamp-on of Flammability of Materials: Flammability Properties
and the welded-on probe thermocouple registered lower of Engine Compartment Fluids Other Than Gasoline;
temperatures, due to the forced convective cooling Auto Ignition Characteristics of Non-Gasoline Motor
acting on the thermocouple sheathing. These two Vehicle Fluids on Heated Surfaces”, National
thermocouples also exhibited a delay in response and Highway Traffic Safety Administration Docket No.
exhibited a significant temperature increase after the NHTSA-98-3588-193.
vehicle engine was turned off. The delay in response 4. Arndt, S. M., Stevens, D. C., Arndt, M., W., “The
was associated with the thermal mass of the Motor Vehicle in the Post-Crash Environment, An
thermocouple construction, whereas, the measured Understanding of Ignition Properties of Spilled
increase in surface temperature was believed to be Fuels”, Society of Automotive Engineers, Paper
associated with the cessation of forced convective # 1999-01-0086.
cooling acting on the thermocouples’ housing and where 5. LaPointe, N. R., Adams, C. T., Washington, J., “Hot
applicable on the clamp attachment method. Surface Ignition of Gasoline on Engine Materials”,
Consequently, these types of thermocouple are not
Society of Automotive Engineers, Paper #
appropriate for surface temperature measurements
2006-01-1013.
where forced convection or quickly changing
6. Davis, S., Chavez, D., Kytomaa, H., “Hot Surface
temperatures may be experienced. Furthermore, this
suggests that the surface temperature measurements of Ignition of Flammable and Combustible Liquids”,
the initial four vehicles are lower than the actual Society of Automotive Engineers, Paper #
temperatures that were attained and that the increase in 2006-01-1014.
measured temperature after the engine was turned off 7. Fournier, E., “Under Hood Temperature
was a phenomenon associated with the specific Measurements of Four Vehicles”, Biokinetics Report
thermocouple and attachment method. to the Motor Vehicle Fire Research Institute, Report
No. R04-13b. September 7, 2004
For the most part, the results of the thermocouple 8. Fournier, E., Bayne, T., “Assessment of
evaluations suggest that the temperature increases Thermocouple Attachment Methods for Measuring
previously recorded [Ref. 7] were an artifact of the Vehicle Exhaust Temperature”, Biokinetics Report to
thermocouple and attachment method. Nevertheless, the Motor Vehicle Fire Research Institute, Report
there was some indication that a slight temperature No. R06-23b, August 19, 2006.
increase may be possible in areas where localized
thermal gradients exist. When the source of heat is CONTACT
removed the region of lower temperature would increase
to equalize with a decreasing higher temperature region. Ed Fournier
If the hottest location is selected, one would not expect to Tel: (613) 736-0384 ext. 226
see an increase in temperature. Fax: (613) 736-0990
E-mail: Fournier@biokinetics.com