Professional Documents
Culture Documents
A203-DeckA-Pier Table-Pre-filled Stressing Form
A203-DeckA-Pier Table-Pre-filled Stressing Form
A203-DeckA-Pier Table-Pre-filled Stressing Form
22K007
VSL Afmmbni
. Strand Threading Record
0^|NI
Date:
.
Scot ^ [70 c^wv k^oo^O<SQ3 ^c2^o^3Z.q z^
^\^ (^oo^uw ^SbOOOCO? Ji<'Z;-l02. S^ z^
'3c^^ (2o^-^^ l^^ooo^o^ ^Z^OZS^ ^
Date (i c
mm a. b. % -Wedges
kN Bar Bar mm
6 8 10 11 12 13 14 15 16 17
1 2 4 5
HeadatENDA: JackNo.
END A
jsJiaos
0 0 0
Name:
Checked by:
DCK JVs Representative (Main Contractor) Sign:
Name:
Checked by:
AECOM's Representative [Supervisor's Delegate) Sign:
JOD NO. : £ZIWUt
Location: Threading Record Tendon infDrmation Jack Information Caksulated by: Page No.
PierA2-03 Deck A
Coil no. Haatno. No. of strand No. of strand: 27 ZPE-750
A2-DeckA
FCZ402329 K450000603 27 Area(mm2):
Tendon : E-Mod.(kN/mm2):
3C02L
Jack. Force (kN):
Gauge pressure Extenstan
Location Shsssing load
kN % Bar Bar mm
1 2 3 4 5 7
END A
0 0 0
1412.5 25 117
2825.0 50 234
4237.5 75 352
50 3x4 ^
OC Checking before stressing (Ie Anchor Block Installation) Min 66.1 .
10'A
Name:
Checked by:
DCKJVs Representative (Main Contractor) Sign:
Name:
Checked by:
AECOM's Representative (Supen/isor's Delegate) Sign:
JOD NO. : ZZ^UU/
. ocaffon: Threading Record Tendon information Jack Information Calculated by: Page No.
PierA2-03 Deck A
Coil no. Heatno. No. of strand No. of strand: 27 JackType: ZPE-750
A2-DeckA
AVa
FC2402329 K450000603 27 Area (mm2): 150.0 Jacklength(mm): 1200.0
Checkedby.
Tendon; E-Mod.(kN/mm2): 199.0 Jacktosses(%): Ace. To calibration
3C01L AVa
Jack.Force(kN): 5650.0 Area (dn2): 1247.0
mm a- b- mm % -Wedges
KN % Bar Bar mm
4 5 9 10 11 12 14 15 16 17
1 2 3 6
HeadatENDA: JackNo.
END A
JSJ1WW
0 0 0
352 HeadatENDB:
4237.5 75
Tendon is free to move- Normal / Abnormal / Not Applicable Ideal 73.5 Comments:
Name:
Checked by:
DCK JVs Representative (Main Contractor) Sign:
Name:
Checked by:
AECOM'sRepresentative[Supervisor's Delegate) Sign:
JODNO.-. ^IWUI
Location: Threading Record Tendon information Jack Information Calculatedby: Page No.
PierA2-03 Deck A
Coil no. Heat no. No. of strand No. of strand:
A2-DeckA
FC2402329 K450000603 27 Area (mm2):
KN % Bar mm mm
1 2 3 4 6
END A
0 0 0
1412.5 25 117
2825.0 so 234
4237.5 75 352
50 3x4 ^
OC Checkingbeforestressing (IeAnchor Block InstallaVon) Mln 66.1 -10%
Name:
Checked by:
DCKJVsRepresentative(Main Contractor) Sign:
Nanie:
Checked by:
AECOM'sRepresentative (Supew/sor's Delegate) Sign:
Project
VSL
Bridge A2-Deck A
Tendon 3C01L
Coil no. Area E Nos.
0 0 0
150
150 x 195
Modified Extension em= eo Amx Em 75 x 150 x 195
150 x 199. 000
73 mm
Project:
VSL
Bridge A2-Deck A
Tendon 3C01R
Coil no. Area E Nos.
FC2402329 150 199 27
0 0 0
0 0 0
150
Modified Em: £'1 xn, +Ez xn;+£3 xng = 199 x 27 + 0x0 0x0
HI + HZ + H3 27+0
199.0
150x195
Modified Extension em = eo x ^^ ^ ^^ 75 x 150 x 195
150 x 199.000
73 mm
Project:
VSL
Bridge A2-Deck A
Tendon 3C02L
Coil no. Area E Nos.
FC2402329 150 199 27
0 0 0
0 0 0
150
150x195
Modified Extension em = eo x ^ ^ g. 75 x 150 x 195
150 x 199. 000
73 mm
Project:
VSL
Bridge A2-Deck A
Tendon 3C02R
Coil no. Area E Nos.
FC2402329 150 199 27
0 0 0
0 0 0
150
Modified Em: ffi xn, +£z x"2+^3 x"3 = 199 x 27 0x0 0x0
Hi + n; + n3 27+0
199.0
150 x 195
Modified Extension em ==eo Amx Em 75 x 150 x 195
150 x 199.000
73.5 mm