EMPOWERING

MEASUREMENT

Digital Multimeter

DM6K1 DM6K2
Trms
Common Features For Motwane DM6K1 & DM6K2
6000 Count LCD display with pleasant blue backlit.
60 position Analog bar graph for trend indication.
Min, Max, Data and Range hold, Relative measurement facility. (Min Max available in DM6K1 only)
Selectable Frequency and Duty Cycle measurement. (available in DM6K1 only)
Highly linear Readings.
Selectable Centigrade and Fahrenheit readout Temperature measurement.
Polycarbonate, Rugged, Dust proof and fire retardant case for high temperature endurance.
CE and EN 61010-1 CAT IV- For enhanced safety in outdoor use. (available in DM6K1 only)
15 minutes Auto power off facility provided to save battery life.
Auto ranging.
Capacitance, Resistance, Diode and Continuity < 30Ω . (Capacitance -DM 6K1 only)

Common Technical Specification for Motwane DM6K1 & DM6K2


DC Voltage :
Range Resolution Max. Reading Accuracy Overload protection
±(Reading + Digit)
600 mV 0.1 mV 599.9 mV ± (0.5% +3 digit)
6V 1 mV 5.999 V ± (0.5% +3 digit)
60 V 10 mV 59.99 V ± (0.5% +3 digit) 1050V DC/AC rms
600 V 100 mV 599.9 V ± (0.5% +3 digit)
1000 V 1.0 V 1000 V ± (0.8% +3 digit)
Input impedance: 10M ohms approx
DC CURRENT RANGE
Accuracy
Range Resolution Max. Reading ±(Reading + Digit) Overload protection
60 mA 0.01 mA 59.99 mA ± (1% +5) 0.8A DC/AC Fuse
600 mA 0.1 mA 599.9 mA ± (1% +5) Protection
6A 1mA 5.999 A ± (1% +5) 20A/600V Fuse
20A 10mA 20.00 A ± (1.2% +5) Protection

OHMS RANGE :

Range Resolution Max. Reading. Accuracy Overload protection


±(Reading + Digit)
600Ω 0.1Ω 599.9 Ω ±(0.5 % +3)
6 KΩ 1.0 Ω 5.999KΩ± (0.5 % +3)
60KΩ 10 Ω 59.99 KΩ± (0.5 % +3) 440V DC/AC rms
600 KΩ100Ω 599.9 KΩ± (0.5 % +3)
6MΩ 1.0 KΩ5.999 MΩ± (1.0 % +5)
60 MΩ 10KΩ 59.99MΩ± (3.0 % +5)

Note: Open Circuit voltage on all OHM ranges are 0.6V DC approx

AC Voltage (50Hz to 500Hz) (Average for DM6K1 & Trms for DM6K2) : DIODE TEST :

Accuracy Open Circuit


Range Resolution Max. Reading Overload protection Voltage Test Current
±(Reading + Digit)
6V 1 mV 5.999 V ± (1.0 % +5) < 2.0 VDC 0.8mA approx.
60 V 10 mV 59.99 V ± (1.0 % +5) 1050V DC/AC rms
600 V 100 mV 599.9 V ± (1.0 % +5) CONTINUITY TEST :
750 V 1V 750 V ± (1.0 % +8) RANGE:
Input impedance: 10M ohms shunted by 30 pF approx. Gives audible beep when
Resistance is below 30Ω.
AC CURRENT RANGE (50Hz to 500Hz) (Average for DM6K1 & Trms for DM6K2) :

Range Resolution Max.Reading Accuracy Overload protection


±(Reading + Digit)
60 mA 0.01 mA 59.99 mA ± (1.2% +5) 0.8A DC/AC Fuse
600 mA 0.1 mA 599.9 mA ± (1.2% +5) Protection
6A 1 mA 5.999 A ± (1.2% +5) 20A/600V Fuse
20 A 10 mA 20.00 A ± (1.5% +5) Protection
Additional Specifications for Motwane DM6K1 (Average)
CAPACITANCE RANGES

Range Resolution Max. Reading Accuracy Overload protection


±(Reading + Digit)
40 nF 0.01nF 39.99 nF ± (3.0%+10)
400 nF 0.1 nF 399.9 nF ± (3.0%+10)
4 µF 1 nF 3.999 µF ± (3.0%+10) 440V DC/AC rms
40 µF 10 nF 39.99 µF ± (3.0%+10)
400 µF 100 nF 399.9 µF ± (3.0%+10)
4000 µF 1 µF 3999.9 µF ± (5.0%+10)
FREQUENCY RANGES

Range Resolution Max. Reading Accuracy Overload protection


±(Reading + Digit)
10 Hz 0.001 Hz 9.999 Hz ± (0.1%+3)
100 Hz 0.01 Hz 99.99 Hz ± (0.1%+3)
1 KHz 0.1 Hz 999.9 Hz ± (0.1%+3) 440V DC/AC rms
10 KHz 1.0 Hz 9.999 KHz ± (0.1%+3)
100 KHz 10 Hz 99.99 KHz ± (0.1%+3)
1000 KHz 100 Hz 999.9 KHz ± (0.1%+3)
10 MHz 1 KHz 9.999 MHZ ± (0.1%+3)
Accuracy is specified at < 20 VAC rms
Sensitivity: 10Hz to 100 KHz > 50mVrms, 1000 KHz to 10MHz >5Vrms
OPTIONAL :
K- TYPE THERMOCOUPLE *
Motwane DM6K1
RANGE ACCURACY
0 0 0
- 20 C TO 300 C ± (2% + 3 C)
0 0
- 4 F TO 572 F ± (2% + 60F)

Additional Specifications for Motwane DM6K2 (Trms)

DC mV:
Accuracy
Range Resolution Max. Reading ±(Reading +Digit) Overload protection
60 mV 0.01 mV 59.99 mV ± (0.5% + 3 digit)
440V
600 mV 0.1 mV 599.9 mV ± (0.5% + 3 digit)
Input impedance: >1000M ohms approx

AC mV (50Hz to 500Hz):

Range Resolution Max. Reading Accuracy Overload protection


±(Reading + Digit)
60 mV 0.01 mV 59.99 mV ± (1 % + 5)
440V
600 mV 0.1 mV 599.9 mV ± (1 % + 5)
Input impedance: >1000M ohms approx.

OPTIONAL :
K- TYPE THERMOCOUPLE
RANGE ACCURACY
0 0
- 200 C to 1200 C ± (2% + 30C)

Specifications can be validated using standard available calibrators and in decade ranges only.
Motwane DM6K2 (Trms)
Kiran’s Creation - 2315598
General :
Display : 6000 Count LCD display with blue backlit.
Polarity : Automatic
Update Rate : 3 per second nominal
Sensing : Average sensing for DM6K1 & Trms for DM6K2
Dimensions (LxWxH) : 94 x 36 x 205 mm. approx.
Weight : 450 g. approx.
Standard Accessories : Pair of leads, User Manual, Battery Installed, Carrying Bag.
Optional Accessory : Pair of leads, K type thermocouple

Environmental :
Operating Temperature : 00C to 500C
Storage Temperature : -200C to 600C
Relative Humidity : 80% at 50C to 310C , 50 % at 310C to 400C non – condensing
Power :
Power Supply : (For DM6K1- 1.5 V AAA size X 2) & (For DM6K2 9V6F22 or equivalent)
Power Consumption : (For DM6K1- 3.2mA Typical) & (For DM6K2 - 8mA Typically)
Low Battery Indication : 'Lo Bat' is displayed. below 2.4V approx. for DM6K1 & below 6V for DM6K2.
Auto Power OFF : 15 minutes Idle Sleep mode consumption 10 Micro amp. approx.

Over Load Protection :


Fuse protection for mA Input Terminal : 0.8A/ 600V fast blow type ceramic fuse
Fuse Protection for 20A Input Terminal : 20A/600V fast blow type ceramic fuse
V/Ω
/C/D/Con : 440 V DC/AC rms

Rev.:09/03/00/Qty:5k
Safety :
Transient Protection : 8 kV (1.2/50µs Surge) as per IEC 1010.1-92

Accuracy :
Accuracy is valid from 10% of range to 95% of the range.
Accuracy is specified as ± % of reading and is valid at 25 ± 30C, 55% ± 10% RH.
(It is recommended that calibration equipment used to verify the accuracy of the instrument should be 10 times more accurate.)

The Motwane Manufacturing Company Pvt. Ltd.


REGD. OFFICE & FACTORY : Gyan Baug, Nashik Road, Nashik - 422 101. Tel.: 91 - 253 - 2463752 / 53. Fax : 91 - 253 - 2463197 e-mail: sales@motwane.com
MUMBAI : 434 A, Gyan Ghar, 14th Road, Khar (W) Mumbai- 400 052. Tel.: 91-22 -26058895 / 96 / 97 Fax : 91 - 22 -26058898 e-mail : mumbai@motwane.com
DELHI : 2 D, 2nd Floor, Vandana Building, 11, Tolstoy Marg, Cannaught Place, New Delhi-110 001. Tel.: 91- 11 - 41522 105. Telefax : 91-11 - 41522106.
e-mail : delhi@motwane.com
BANGALORE : # 8/12, 3rd Floor, Honnam Complex, South Cross Road, Basavanagudi, Bangalore-560004. Tel. : 91- 80 - 26621186 / 26611323.
e-mail : bangalore@motwane.com
KOLKATTA : Abhamoni, 1/58, M.M. Ghosh Road, Kolkatta- 700074. Mob : 91- 9831047220, e-mail : saha.partha@motwane.com

Chandigarh : 91- 9779150088 Chattisgarh : 91- 9630086998 Pune : 91- 9096080757 Andhrapradesh : 91- 9177032227, 9000566172
Uttara khand : 91- 9760425639 Jharkhand : 91- 9771407481 Nagpur : 91- 9096080758 Tamilnadu : 91 - 9677048844, 9677038844
Uttarpradesh : 91- 9956274444 Orissa : 91- 9937086545 Madhya Pradesh : 91- 9630089860 Goa / Hubli : 91- 9008500283
Bihar : 91- 9771407482
NOTES

1. The Instrument is accompanied with Test & calibration sheet. 2.Test Facilities can be provided at the factory with the availabletest set-ups only. 3. The Company's policy is continuous improvement
of its products. we therefore reserve the Right of any deviation from illustration or specifications without notice. 4.Stated accuracies are valid from 1/10th of range to FS. 5.Accuracy Specified for Printed on recycled paper
temperature range of 250C ± 50C& 55%RH ±10%.

You might also like