www .rohrpost.de Air Tube Transport Systems
Standard
07-2004
The Standard-Systems
for 255 zones and up to 32,000 s tations with different types of stations for 1 to 16 digit selection
correspondens to all requirem ents of the medium sized and large enterprises to modern in-house
communication 7and logistics .
The system works in Computer-technics, the stations are equ ipped with LCD-display and
keyboard.
Hörtig rohrpost offers various accessories an d customer specified devices es pecially with the
System H61.
System H61
Through-Station
451
Endstation 421
The system works in Mc - technics, the stations are equipped Remote control
with LC-display and numerical keyboard.
For sending and receiving the same conveyor tube is used, the direction of transport is
controlled by means of the switching over from sucking to blowing air at the blower.
At the sending stations the respectively destination is selected and the carrier will be transported
automatically.
The palette of accessories ranges from a standard interface for record printer, system self-control,
speed-control of the driving carrier, remote maintenance up to the priority-switching or switching off of
single stations in case of absence.
The HÖRTIG Air Tube Transport System H61 is used for the transport of delivery notes, invoices,
electronic data lists, photos and films, tools, samples, laboratory specismen, glasses, remedies,
marking plates, wheigt notes and other vouchers in all branches of enterprises, as well as for the trans-
port of blood and X-ray photographs, proscriptions a.s.o. in the field of hospitals.
05-2006
· Interfaces
· CAN-Bus interface
· Programmer - connector
· serial interface V.24
· serial interface RS485
· parallel port, Centronics print er interface (IEEE448) opto c oupled
· 2 relay outputs with isolated c ontacts for signalling full and part error of the system
· capability to drive blower, air dir ection switch, air brake, dr ive speed regulation
· electromechanical counter for all transports done
· System bus-system
· communication to all other dev ices of the system via a standard industrial field bus.
· This CAN-Bus system was developed by Bosch AG – Germany for car brake’s ABS data
transmission
· All sensors or time critical inform ation can be sent by everyone on the bus (Multi-Master
bus) it is not necessary for the m ain-controller to ask the stations for information.
· The bus can guarantee a transmission time of 20 ms for any information (real-time)
· Up to 128 members on the bus (nodes)
· Very long distance without repeaters (up to 1 km / 10 k Baud)
· very secure data transmiss ion (6 bit Hamming distance)
· the bus system is hot-change capable. Components can be changed, while the s ystem is
working.
· the system is error passive. This means that components which fail will not caus e problem
on the other devices on the bus.
· Power supply
· Standard power supply: 240V AC - 38V DC / 2,5A included (up t o 1 km / 15 stations)
· Optional 85-256V AC – 48V DC / 5A (up to 3 km / 35 stations)
· CE – standard
· consequently ESD protected – CE-confirm design
· Product
Developed, manufactured and programmed by HÖRTIG rohrpos t - Germany
05-2004
· Software
· printer / statistics:
· memory of the last 300 transpor ts with date, time, from s tation, to station, passed
switches,
· cross-table with information: who to whom and how many carriers
· listing of existing numbers
· all system set-up protocol
· permanent protocol printing of all actions of the system
· protocol data
· sender, receiver number
· date and time
· all switches of the running job
· error and blower information
system:
· number of station with problem or error
· number of stations with error
· all system state
· power management
· printer management
· bus errors
· service mode
· different levels of user right s controlled by passwords
· fully menu controlled (SAA like)
· access to the menu by an opt ional hand held pocket term inal for mobile service or PC
program
· all configuration, user modes, test functions, protocol s, system start/stop and so on are
controlled with this menu
· all system functions can be ac cessed from any location of the s ystem
· easy to handle service functions like m otor test, single step, switch test or complete self
test automatic system control:
05-2004
· carrier management
· chronological and priorit y controlled sending order
· the system supports automatic carrier return by transp onder HF-TAGs
· the system will support automatic carrier distribution by statist ical methods (account-
system)
· all devices are permanently super vised by the system, the interval is i ncreased for actual
used parts of the system.
· all positions of mechanical devic es are permanently check ed
· the moving carrier is monitored
· driving time
· sensors passed
· order of sensors, number of activation
· missing sensors
· following faults are detected an d automatically handled by the s ystem
· more than one carrier at the same tim e moving
· mechanical device not moving bec ause of blockage, wear,
· device no more in a legal st ate
· intelligent motor motion contr ol
· error management
· Auto-purge after several errors the s ystem start a IPurge
· IPurge - intelligent purge the system will purge onl y the sender or receiver in m ost efficient
order – this will save a lot of tim e. The carrier will arrive at the original destination number
or at the sender or at the def ault station.
·
· Types of errors detected and m anaged by the software:
A) calculated total transport tim e is exceeded 3 times
B) double carrier detected becaus e of:
- switch order
- switch distance time
- switch double detected
C) IPurge
D) Sender error – e.g. carrier taken out of station r ight before start
E) Receiver error – e.g. basket full and blocked
· All mechanical blockages are un-blocked by the trouble shoot er software. This is moving
the motors both directions and s witching air until detecting a car rier in the system or free
the motor.
· The trouble shooter tries to free m otors 5 times before is give up this trials and set the
device on “damaged”. These att empts are performed while no c arrier is sent by the user.
· Section error: if a part of t he system is in trouble, the system will no m ore use this section,
but continue with the other stations. The inform ation about a section error is gi ven out on
the Error-relay on the controller.
· If the system cannot work an y more, e.g. no blower air, th e system will switch off and
activate the Off-relay on the controller
These large number of error management algorithms is unique on the m arket. We have
analysed all our 37 year experie nce on tube systems to find the m ost probable errors of tube
systems and we have developed h ard and software to inhibit or automatic solve this trouble.
05-2004
· Multi-zone
· The system is prepared to be diverted into independent subsystems. This will incr ease
system performance enormous.
· each subsystem can run one car rier
· up to 256 zones can be connecte d
· the connections can be done in r ing, star or network topolog y
· all modes will detect and use redundant s tructures automatically
· the zone interchange system is hot-change capable
· traffic load management
· the zone links can be equipped with buffers
· the zone interchange proces s can be secured with transponder T AGs in the carriers
· the number and device managem ent from the PC will control all zones.
Station H61E
· Mechanical Hardware
· braked arrival of all carriers T he carriers are braked by air cushions long time before they
arrive in the basket
· sheet steel case in modern desig n
· zinc plated and powder painted
· safe snap of the tube positions into correct position
· easy service – opened by key-lock
· suction and pressure tight
· all electrical functions are c hecked with the programmer, c onnected to the station
· ball bearings
· Ergonomic
· one-hand usage – the user is able to send a carr ier while carrying something else
· consequently ESD protected – CE conform design
· low noise send and receive
· Electrical Hardware
· 7 MHz CPU
· 8-bit CPU
· 64 Kbytes Flash ROM
controller software, online or Bus update is supported
· all inputs and outputs are opto c oupled
· switch power supplies (16-60 V DC)
· 2 x 16 LC-Display, illuminated, super-twist-technology
or
· 32x122 Pixel graphic LC-Module for non-Latin fonts like Greek, Sim ple Chinese, Traditional
Chinese, Korean, Thai
· membrane keyboard and LED`s – easy to clean, colour icons desc ribe function
· Interfaces
· CAN-Bus interface
· Programmer - connector
· serial interface V.24
· 2 motors and one solenoid driver s
· 10 arrival signal drivers
· 8 carrier sensor drivers
· 2-16 position switches
05-2004
· Software
· LCD - Module
· Screen-saver
· Operating state of system
· Extensive user dialogue for exam ple
· Repeat last number
· The system gives feed-back within 2 seconds
· The destination can be alright, s witched off, full basket, on ho lyday or absent
· Sending:
· Follow me function with confirm ation of redirection
· Sending priority with auto-function
· Sending speed with auto-function
· LEDs
· Green: waiting carrier is book ed
· Red: system is busy
· Yellow: Carrier coming
· certain prevention of malf unction
· unblocking carriers
· repositioning on switches
· motors:
· monitored position-switches
· monitored power consumption, s hort-circuit protected, auto-repeat function
· motor speed and torque is adjus table by software
· Keyboard with buzzer-click for feed-back
· Heartbeat for function test
· Optional connection to a card reader system to identify the actual user of the system and
station.
05-2004
Diverter
· Mechanical Hardware
· sheet steel case in modern desig n
· zinc plated and powder painted
· safe snap of the tube positions in to correct position
· easy service – opened by key-lock
· suction and pressure tight
· all electrical functions are c hecked with the programmer, c onnected to the station
· ball bearings
· Electrical Hardware
· Passive diverter
· Controlled by nearest statio n
· No need to access diverter for test of controller
or
· Active diverter
· 7 MHz CPU
· 8-bit CPU
· 64 Kbytes Flash ROM controller s oftware, online or Bus update is supported
· all inputs and outputs are opto c oupled
· switch power supplies (16-60 V DC)
· Interfaces
· CAN-Bus interface
· Programmer - connector
· 1 motor
· 8 carrier sensor drivers
· 2-16 position switches
· Software
· certain prevention of malf unction
· unblocking carriers
· repositioning on switches
· motors:
· monitored position-switches
· monitored power consumption, s hort-circuit protected, auto-repeat function
· motor speed and torque is adjustable b y software
· Hartbeat for function test
05-2004
Hospital
07-2004
PC + DSL
PC + DSL
06-2005
Hospital Stations
Examples of use
04-2000
Stations
07-2004
1.0421 1.0451
1.0472 1.0461
= Senden / Send
www.rohrpost.de
1.0118 1.0218
Tischeinbau-Station 1.0218.x.CE
Desk-Station
Bei Planung bzw. Installation ist besonders darauf zu achten, Consider at planning - installation especially, that there is
dass über der Sende-/Empfangsöffnung ausreichend freier Raum enough freespace above the sending- receiving opening for
für die verwendeten Transportbehälter ist, damit kein Stau, mit the arriving carriers, so that this can`t lead to a stuck with
verbundener Anlagenstörung, entstehen kann. following malfunctions of the system.
J
K K
J
J J
K
A
B
C
H1
K
H2
R
J
A 380
B 230
C 60
K 370
J 180
R 650
H1 90
H2 780
02-2007
www.rohrpost.de
Station 1.0421.x.CE
Station
Ankunft des Transportbehälters von oben, Arrival of the carrier from top, sending upwards.
Senden nach oben.
Station 1.0421.x.CE
Do
W
M X
Y
H3
H
B T
S
N P
R
45,0 Q
53,0
300,0
285,0
B 375 375 375 375 375 375 375 375 375 500
H 378 378 378 378 378 378 378 378 378 375
H3 460 460 460 460 460 460 460 460 460 480
M 96,5 96,5 96,5 96,5 96,5 96,5 96,5 96,5 96,5 125
N 450 450 450 450 450 450 450 450 450 650
P 340 340 340 340 340 340 340 340 340 340
Q 310 310 310 310 310 310 310 310 310 310
o R 500 500 500 500 500 500 500 500 500 500
o S 1250 1250 1250 1250 1250 1250 1250 1250 1250 1250
T 250 250 250 250 250 250 250 250 250 302
W 70 68,5 65 60 55 46 45 45 45 50
X 100 100 100 100 100 100 100 100 111 130
Y 30 30 30 40
Z 296 296 296 296 296 296 305 305 350 375
01-2011
o= wichtig / important!
www.rohrpost.de
Station 1.0451
Station
Ankunft des Transportbehälters von oben, Arrival of the carrier from top, sending upwards.
Senden nach oben.
sheet-steel case, moulded-case, modern design
Stahlblechgehäuse in kompakter Bauform und plastic-covered, white-grey appr. RAL 7035
modernem Design
kunststoffbeschichtet, weiß-grau etwa RAL 7035 Dimensions:
Abmessung: Do60-Do132: appr. 658mm x 408mm x 335mm
Do60-Do132: ca. 658mm x 408mm x 335mm Do160: appr. 778mm x 504mm x 365mm
Do160: ca. 778mm x 504mm x 365mm Weight:
Gewicht: Do60-Do132: appr. 23kg
Do60-Do132: ca. 23kg Do160: appr. 33kg
Do160: ca. 33kg
Consequently ESD protected
EMV - konform.
09-2008
Station 1.0451.T.2E
Station
Ankunft des Transportbehälters von oben, Arrival of the carrier from top, sending upwards.
Senden nach oben.
Station 1.0451.T.3E
Station
Ankunft des Transportbehälters von oben, Arrival of the carrier from top, sending upwards.
Senden nach oben.
Station 1.0451
G
F
E
B2
A 1820 1820
B 408 408 408 408 408 408 408 408 408 504 615
B1 400 400 400 400 400 400 400 400 400 500 615
B2 460 460 460 460 460 460 460 460 460 630
D 80 80 80 80 80 80 80 80 80 170
E 190 190 190 190 190 190 190 190 190 173
F 75 75 75 75 75 75 75 75 75 55
G 250 250 250 250 250 250 250 250 250 390
H 658 658 658 658 658 658 658 658 658 778 1070
H1 650 650 650 650 650 650 650 650 650 771
H2 685 685 685 685 685 685 685 685 685 830
K 66 64,5 61 56 51 42 41 41 21 25 5
N 450 450 450 450 450 450 450 450 450 650 650
P 340 340 340 340 340 340 340 340 340 450 450
Q 310 310 310 310 310 310 310 310 310 400 400
R 500 500 500 500 500 500 500 500 500 500 500
S 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
T 335 335 335 335 335 335 335 335 335 365 460
U 550 550 550 550 550 550 550 550 550 730 760
V 200 200 200 200 200 200 200 200 200 250 200
W 160 158,5 155 150 145 136 135 135 124 155
X 190 190 190 190 190 190 190 190 190 235
05-2005
Z 27 27 27 27 27 27 27 27 27 53 50
rohrpost
www.rohrpost.de Air Tube Transport Systems
Station 1.0452
Station
Ankunft des Transportbehälters von oben, Senden nach oben. Arrival of the carrier from top, sending upwards.
Station 1.0452
W
U
~ 1m
Do F G
X
E
H2 +- 5
D
T
Z +- 3
S
B Luftventil für evtl.
N Außenluft-Ansaugung P
Air-valve for
fresh air suction
R
Q
O
B 403 403 403 403 403 403 403 403 403 504 615
D 80 80 80 80 80 80 80 80 80 170
E 190 190 190 190 190 190 190 190 190 173
F 75 75 75 75 75 75 75 75 75 55
G 250 250 250 250 250 250 250 250 250 390
H 650 650 650 650 650 650 650 650 650 771 1070
H2 675 675 675 675 675 675 675 675 675 820 1120
N 450 450 450 450 450 450 450 450 450 650 650
O 400 400 400 400 400 400 400 400 400 620 620
P 340 340 340 340 340 340 340 340 340 450 450
Q 310 310 310 310 310 310 310 310 310 400 400
R 500 500 500 500 500 500 500 500 500 500 500
S 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100 1100
T 312 312 312 312 312 312 312 312 312 365 460
U 550 550 550 550 550 550 550 550 550 600 650
W 160 158,5 155 150 145 136 135 135 124 155
X 190 190 190 190 190 190 190 190 190 235
Z 27 27 27 27 27 27 27 27 27 53 50
05-2006
rohrpost
www.rohrpost.de Air Tube Transport Systems
Station 1.0461.T.CE
Station
Abmessung:
Dimensions:
Do160: HBT: ca. 800mm x 500mm x 527,5mm
Do160: HWD: appr. 800mm x 500mm x 527,5mm
EMV - konform.
Consequently ESD protected
Änderungen vorbehalten!
We reserve the right of changes!
05-2006
Station 1.0461
E
E
D
C
160 153 1620 500 1560 1750 70 800 858 60 450 400 340 310 400 950,0 500 530 160 60 140 110
benötigter Montagebereich
assembly area
810mm
775mm
35mm 50mm
280mm
800mm
360mm
160mm
für Wandbefestigung
for wall-mounting
27mm
10-2008
www.rohrpost.de
Station 1.0472.x.CE
Station
Ankunft des Transportbehälters von unten, Arrival of the carrier from below, sending downwards.
Senden nach unten.
Station 1.0472
U W
V X
E
H1
YD
B T
S
N P
C
Do
R
Q
O
B 400 400 400 400 400 400 400 400 400 534
C 952 952 952 952 952 952 952 952 952 952
D 455 455 455 455 455 455 455 455 455 455
E 410 410 410 410 410 410 410 410 410 410
F 190 190 190 190 190 190 190 190 190 170
H 650 650 650 650 650 650 650 650 650 731
H1 686 686 686
I 230 314,6
J 116 136,3
K 200 265
L 120 145
N 450 450 450 450 450 450 450 450 450 650
O 400 400 400 400 400 400 400 400 400 620
P 340 340 340 340 340 340 340 340 340 450
Q 310 310 310 310 310 310 310 310 310 400
R 400 400 400 400 400 400 400 400 400 310
S 1000 1000 1000 1000 1000 1000 1000 1000 1000 850
T 375 375 375 375 375 375 375 375 375 440
U 550 550 550 550 550 550 550 550 550 1100
V 200 200 200 200 200 200 200 200 200 267
W 50 49 46 40 35 25 25 25 25 40
09-2008
X 80 80 80 80 80 80 80 80 91 120
Y 110 110 110
www.rohrpost.de
Auslaufbügel 1.0026.T.00
Receiving-bow
88cm
13
,5c
m
60cm
Auslaufbogen Receiving-bow
für Endstationen mit offenem Empfang. for endstations with open receipt.
Ankunft des Transportbehälters von oben, Arriving of the carrier from top,
Senden nach oben. sending upwards.
Labor-Station Do160
Laboratory-Station
Labor-Station Laboratory-station
für Fahrrohr-Durchmesser Do160 for tube-dimension Do160mm
mit: with:
Sendestation 421 Sending station 421
und and
Empfangsstation 451. Receiving-station 451.
Der waagrechte Empfang der Behälter auf dem The horizontal receive of the carriers at the
Förderband gewährleistet höchste Schonung conveyor belt ensures a careful and quick
des Ladegutes und schnelles Handling bei der handling.
Entnahme des Transportbehälters.
Die Abmessung der Laborstation ist variabel The dimensions of the laboratory-station
entsprechend der verwendeten Stationstypen depends on the station types which are used.
für Senden und Empfangen.
Lab 1 Lab 2
452 452
452
2-fach
2-fold
Lab 3
Lab 4 - MULTICARRY
640G
Transfer-Revolver 1.0630
221
221 + Bremsschieber
+ brake
640G
- Handy - handy-phones
- Brillengläser - glasses
- Injektionen - injektions
- Pathologie - pathology
- Medikamente - medicaments
- Blutröhrchen - blood tests
- Werkzeuge - tools
- Bohrer - drills
- Fräser - cutters
Ankunftsignal 1.1862.0.00
Arrival signal kit
- mit blinkender LED-Anzeige und Summer - with flashing signal-LED and buzzer
- Bodenplatte Metall, grau RAL 7035 - metal plate, grey RAL 7035
- Deckel transparent - cover transparent
Abmessung:(HBT) Dimensions:(HWD)
80mm x 84mm x 50mm 80mm x 84mm x 50mm
- für aP-Installation neben der Station - for o.p. installation beside the station
Ankunftsignale 1.18xx.x.xx
Arriving signals
Raum 1 / room 1
#1 abgesetztes Ankunftsignal
remoted arriving signal
Raum 2 / room 2
#2
Raum 9 / room 9
#9
10 Signalausgänge
10 arriving signal outputs
Benutzer-Leser 1.0620
Staff reader
1.0620.0.0E Benutzer-Leser in der Frontplatte 1.0620.0.0E Staff reader in the front of the
der Station station
Der Einsatz dieser Methode ist äußerst einfach This method is very simple and reliable.
und zuverlässig. The user only has to put the carrier into the
Der Behälter wird nur in die Station gestellt und station and to push the button for sending back.
die Taste für Rückfahrt betätigt.
Der Behälter wird dann automatisch vom System The system reads automatically the carrier
gelesen und zu seinem Heimatbahnhof and send it back to the station where it comes
gefahren. from.
Der wesentliche Vorteil des Systems ist, dass The essential advantage of this system is,
jeder Station eine bestimmte Anzahl von that a fixed number of carriers can be assigned
Behältern zugeordnet werden kann. to each station in the system.
Dadurch können für spezielle Gegenstände Therefore it is possible to use special packing
auch bestimmte Verpackungen im Behälter materials for certain carriers.
mitgeführt werden.
Die Zahl der Leer-Behälter-Speicher wird durch The amount of empty-carrier-storages will be
die Transpondertechnik erheblich reduziert. reduced to a minimum.
Steuerzentrale 1.1062.0.E0
System-control-unit
Das Zusatz-Netzteil wird verwendet: The Additional Power Supply is used when:
- bei Kabelstrecken länger als ca. 500m - the length of cable is more than 500m
- bei mehr als ca. 20 Stationen im System - using more than 20 stations in the system
Die externe Stromversorgung für die weiterführende Anlage The external power supply for the on-going
wird dann an den Klemmen „Power“ angeschlossen. system will be plugged at the clamps “power”.
Programmiergerät 1.1062.0.95
Programmer
sehen S5 view S5
Hauptziel:1234 Target: 1234
Zielnummern target-number
ESC ENT ESC ENT
sehen S5 view S5
Luft: langsam Speed: slow
Geschindigkeit arrival-speed
ESC ESC
sehen S5 view S5
Fahrtzeit: 10 Distance: 10
vom letzten G. from last Dev.
ESC ESC
H61E-Bus
Umsetzer des Systembus H61 auf eine RS 232 C Converter of the system-bus H61to RS 232 C
für die Verbindung des Systems H61mit einem PC. to connect the system H61 with a PC.
Der PC-Anschluß ist auch für Überleitbus This interface also could be used for the
zur Anzeige mehrerer Linien verwendbar. transfer-bus to registrate more line-systems.
Benötigt werden bei einer Linie: Using one line you need:
1 St. PC-Interface 1.1062.0.57 1 St. PC-Interface 1.1062.0.57
1 St. Software RT-WIN Basislizenz 1.1062.0.R0 1 St. Software RT-WIN Basiclicence 1.1062.0.R0
Bauseits: By customer:
PC mit von uns vorgegebener Konfiguration. PC configured according to our instructions.
Software 1.1062.0.R0
Software
Software Software
- ultra-moderne grafische Darstellung in 3D - ultra-modern 3D grafic view
- grafische Anzeige der Position - grafic view of the positions
von Motoren und Rohrschaltern of the motors and tube-switches
- alle Funktionen des - all features and functions of the portable
Programmiergerätes 1.1062.0.95 programming tool 1.1062.0.95
- Anzeige von System- und Gerätestörungen - display of all system- and device errors
- Aufzeichnung von Fahrten - recording of transports with search functions
mit entsprechenden Suchfunktionen for
(Zone, Geräte-Nr., Zielnummer, Zeit, (zone, device-number, destination-number,
Fehler) time, error)
- Anzeige des aktuellen Systemzustandes - display of the current system function state
- mehrsprachig: - multilingual:
deutsch, englisch, französisch, portugisisch, german, english, french, portugese,
chinesisch, thai.... chinese, thai....
System-Voraussetzungen: System requirements:
Software: WINDOWS 2000 / XP Software: WINDOWS 2000 / XP
Prozessor: min. Pentium 2GHz Processor: min. Pentium 2GHz
Speicher: min. 128MB - 256MB RAM: min. 128MB - 256MB
Festplatte: min. 10 - 20GB pro Linie Harddisk: min. 10 - 20GB per zone
Grafik: 64MB Video RAM voll OpenGL-fähig Grafic: 64MB Video RAM OpenGL
Laufwerk: CD-Rom Drive: CD-Rom
Schnittstellen: seriell RS-232 mit Sub-D9-Stecker Interface: RS-232 with Sub-D9-plug
pro Zone per zone
Software für Fernwartung: PC-Anywhere 10.5 Software for remote control: PC-Anywhere 10.5
05-2006
Über eine ISDN-Verbindung kann vom HÖRTIG - With an online connection by ISDN the service-
Servicezentrum in Bayreuth direkt in die center of HÖRTIG in Bayreuth can check all
Funktion der Anlage beim Kunden eingegriffen functions of customer’s system.
werden, um aufgetretene Unregelmäßigkeiten am It is possible to locate systems malfunctions
System zu lokalisieren und dem Servicetechniker and to help customers service engineer to
vor Ort bei der Störungsbehebung zu unterstützen. correct the disturbances.
05-2006
Weiche 1.0395.x0E
Diverter
Abmessung: Dimensions:
Do60-Do132: Do60-Do132:
ca. 650mm x 400mm x 290mm appr. 650mm x 400mm x 290mm
Do160: Do160:
ca. 770mm x 500mm x 353mm appr. 770mm x 500mm x 353mm
Do315: Do315:
ca. 1200mm x 900mm x 700mm appr. 1200mm x 900mm x 700mm
X
H2 +- 5
H3
T
B
Do
B 400 400 400 400 400 400 400 400 400 500 600 900
E 95 95 95 95 95 95 95 95 105 130 165 275
F 190 190 190 190 190 190 190 190 210 260 330 550
G 95 95 95 95 95 95 95 95 95 107
H 650 650 650 650 650 650 650 650 650 770 1070 1200
H2 711 711 711 711 711 711 711 711 711 891 1180 1300
H3 660 660 660 660 660 660 660 660 660 780 1180 1300
T 290 290 290 290 290 290 290 290 290 353 445 700
X 91 91 91 91 91 91 91 91 91 105 140 185
- Please notice that the diverter should be accessible for routine maintenance at any time!
If it is built-in into a false ceiling take care that it is possible to take the diverter completely out.
02-2006
für 2 - 16 Linien Do108, Do110, Do132, Do160 for 2 - 16 zones Do108, Do110, Do132, Do160
- ermöglicht die Beachtung von Prioritäten bei - carriers with high priority can be sent first
Transfers durch Zwischenlagern von Transport- by interim storage of the carriers with lower
behältern mit weniger Priorität priority
- Transportbehälter, deren Ziel derzeit “korbvoll” - Carriers which can not be sent to their
werden ebenfalls zwischengelagert destination in case of “full basket” will be
stored, too
- die Überleitvorgänge werden durch Einsatz
von Transpondertechnik abgespeichert - all transfers will be saved by using most
modern transponder technology
- wesentlich kompaktere Montage als die
herkömmlichen Weichen-Überleitungen oder - implenting the revolver is much better
waagrechten Linearverteiler. than the conventional transfer with diverters
or the horizontal linear-distribution.
Transfer-Revolver-Anschlüsse 1.064x
Transfer-Revolver-Connections 1.064x
1.0395
1.1062.0.E0
1.1062.0.E0
1.0395
1.1062.0.E0
1.0421
1.0395
1.1062.0.E0
1.0422
678
IR-Schalter
1.0641
1.0643
1.0641
1.0642
1.0641
1.0641
IR-switch
1.0641
1.0640
RF RF RF RF RF RF RF RF
1.0651
Rohrschalter - IR 1.1606.V.0D
Tube-switch - IR
Rohrschalter Tube-switch
als Infrarot-Lichttaster as infrared-light pushbutton
mit: with:
- 10 m langem Anschlußkabel zum - 10 m connecting cable for direct
direkten Anschluß (ohne Verteiler) connection (without distributor)
auf der Stationssteuerung in oder on the station-control unit which is
neben der Station oder in einer placed in or beside the station
Weiche. or in a diverter.
1.2184.3.0C 50 380 - 440 1,5 7,4 / 4,3 72 200 3600 2850 345 333 323 23,5
60 380 - 440 1,75 7,4 / 4,3 72 200 4200 2850 345 333 323 23,5
1.2185.3.0C 50 380 - 440 2,2 9,8 / 5,7 76 196 5100 2850 377 382 383 36
60 380 - 440 2,55 10,7 / 6,2 76 196 6200 2850 377 382 383 36
02-2004
Frequenzumrichter 1.2530.0.0E
Frequency controller
262 286
73 PG 16
PG 16
101
157
174
303
2-G1 1 / 2
154
8-M6-1,0
4-o12
/
45
115
72
225
130 255
75 95 68
60 200 - 230 0,9 13,2 / 6,6 160 3000 2850 303 266 262 17
200 200
160 160
120 120
80 80
40 40
0 0
0,0 0,5 1,0 1,5 2,0 2,5 3,0 m³/min 0 0,5 1,0 1,5 2,0 2,5 3,0 m³/min
= Druck / pressure
05-2005
= Saug / suction
www.rohrpost.de
333
323 Pg16
101 Pg16
108,3
177
200
345
48 174,6
8-M8x1,25
4-14 o/
4
55 55
82
120
,5
60 380 - 440 1,75 7,4 / 4,3 200 4200 2850 377 333 323 23,5
250 250
200 200
150 150
100 100
50 50
0 0
0,0 1,0 1,5 2,0 2,5 3,0 3,5 m³/min 0 1,0 1,5 2,0 2,5 3,0 3,5 m³/min
= Druck / pressure
05-2005
= Saug / suction
www.rohrpost.de
382
377 Pg16
124,1 Pg16
123
207
240
383
197
8-M8x1,25
4-15 o/
53
4,5
55 55
82
125
,5
60 380 - 440 2,55 10,7 / 6,2 196 6200 2850 377 382 383 36
250 250
200 200
150 150
100 100
50 50
0 0
0,0 1,0 2,0 3,0 4,0 5,0 6,0 m³/min 0 1,0 2,0 3,0 4,0 5,0 6,0 m³/min
= Druck / pressure
05-2005
= Saug / suction
www.rohrpost.de
Luftventil
air valve
f
b b
X o
e
c
g e c hj l X
nl
a
i k d m i
A B
a
c
A
d
e
f
b a
d c
B g
h
d 45°
i b
d
i
r
C h g
System
f