CONCRETE COMPRESSIVE STRENGHT TEST REPORT NF EN

12390-3
Number of Test Report 166
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 31,6 / 32,4 °C Size of specimen (16 x 32 cm) x 3


Pouring date 9/26/2023 Slump test at 0' 16 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Admix150
Quantity(Kg/m3) 450 178.78 574 260 1018 4
Part of Structure

2nd line Production; Silo; Water tank / Trench; Seed Cleaner; Footing /TR13_F24-F23 wall; TR21_F22-F19E Wall;
TR11_F18-F13C Wall; TR11_F30-F31 Base; F7Base; F4(6pcs); TR17_F3-Base; Silo 2 Wall; Water tank 2

30A100_RFI_184 EXT
Number notification Date of receipt 10/2/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH742 15.70 2.44 465.60 23.16
AH743 7 10/3/2023 15.72 2.44 514.09 25.57 24.38
AH744 15.84 2.46 490.94 24.42

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date

Number notification 30A100_RFI_219 EXT Date of receipt 10/2/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH745
AH746 28 10/24/2023
AH747

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date