الموقع العام

You might also like

Download as pdf or txt
Download as pdf or txt
You are on page 1of 1

1 2 3 4 5 6 7 8 9 10 11 12 13

AS101 B01 3225


SHEET NO. BLDG/SITE NO. PROJECT NO.

LEAD CONSULTANT:

L L

www.ecgsa. com

·· FGL = FIXED GROUND LEVEL = 10 000


FFL = FINISHED FLOOR LEVEL
2 B ·· FPL = FINISHED PAVEMENT LEVEL
FRL = FINISHED ROAD LEVEL
K
AE-201
·· FCL = FINISHED CEILING LEVEL
TOC = TOP OF CONCRETE
K

·· TOPR = TOP OF PARAPET


TOSS = TOP OF STEEL STRUCTURE

· All dimensions are in millimeters, all dimensions should be verified on site and
approved by the authorized engineer.
· Unless otherwise indicated, levels are in meters (m) and angles are in degrees.
EL 26 250 · Drawings are not to be scaled, written dimensions should be followed.
TOPR · All drawings should be read in conjunction with other relevant architectural,
EL 10 000 structural, mechanical, electrical drawings and all other relevant sections of the
J FPL specifications. J
· For symbols & abbreviations, refer to drawing No. AI002
EL 26 250 EL 26 250 · The Contractor shall send site coordinates and levels relative to MSL before
TOPR TOPR execution
EL 26 250 · For the structural elements, refer to structural drawings.
TOPR
· For the structural elements supporting masonry works refer to structural
drawings.
· Unless otherwise indicated, all the structural elements supporting masonry
walls should be within walls thicknesses.
· For external levels, slopes, finishes, dimensions, etc...., refer to landscape &
roads drawings.
H · For Internal Finishes, refer to finishes schedules and interior design H
drawings.
EL 25 600 EL 26 250 · For doors, windows and elevations types' location and dimensions refer to
TOPR TOPR openings drawings and schedules.
· For signage details, refer to signage drawings.
EL 26 250 · Unless otherwise indicated, gypsum board partitions should continue 200
TOPR mm above suspended ceiling finished level.
· Junctions between reinforced concrete and block works should be treated
by metal lath prior to applying plaster.
EL 25 600
TOPR · Fire rated walls, refer to life safety drawings.
· All kitchens and toilets walls should be solid masonry units.
G · Unless otherwise indicated on drawings, door jambs should be located 200 G
mm from the nearest adjacent wall face.
· For exact location and size of MEP openings, refer to structural drawings.
2 1 Shop drawings for the coordinated openings should be submitted to the
AE-202 authorized engineer for approval.
AE-202

EL 25 600
TOPR
EL 28 000
TOPR
EL 10 450 EL 10 000
FFL FPL
F F

EL 25 600
TOC

EL 10 450 EL 25 600
EL 27 400 TOPR
FFL TOC
E E

EL 26 250
AE-301 TOPR AE-301
EL 10 000 EL 26 250 EL 26 250 EL 26 250
FPL EL 26 250 TOPR TOPR TOPR
TOPR
Sheet size - ISO A1 (841*594 mm)

D D

C A JAN 2023 DETAILED DESIGN A.AMKB A.DMIA A.DMIA C.AEMO C


REV DATE ISSUED FOR DRW CHK TL PM
1
100 mm

B PROJECT TITLE:
AE-201

NATIONAL PROJECT FOR BLOOD BANKS


DISCIPLINE

B ARCHITECTURAL B
50 mm

SHEET TYPE

ARCHITECTURAL PLANS
Scanning scale

SHEET TITLE

SITE LAYOUT SITE LAYOUT


1 Scale 1:100 SCALE PROJECT NO. FACILITY NO. SHEET NO. REV . MARK
10 mm

A 1:100 3225 B01 AS101 A A


1 2 3 4 5 6 7 8 9 10 11 12 13 ECG Copyright - Produced Using CAD
THIS DRAWING AND THE DESIGN IT COVERS ARE THE PROPERTY OF THE ENGINEERING CONSULTANTS GROUP .THEY ARE MERELY LOANED ON THE BORROWER'S EXPRESSED AGREEMENT THAT THEY WILL NOT BE REPRODUCED, COPIED, LOANED, EXHIBITED NOR USED EXCEPT FOR LIMITED AND PRIVATE USE PERMITTED BY WRITTEN CONSENT GIVEN BY THE LENDER TO THE BORROWER.
A1