CONCRETE COMPRESSIVE STRENGHT TEST REPORT NF EN 12390-3

Number of Test Report 265


Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Batching plant Loudima

Temperature 33.5 / 32.7 °C Size of specimen (16 x 32 cm) x 3


Pouring date 1/18/2024 Slump test at 0' 14.5 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type Forspak - 42,5N - 0/1 5/12,5 16/25 Epsilone HP 565

Quantity(Kg/m3) 450 115 574 260 1018 2


Part of Structure

Silo; Production Line Shed / Trench; Cake Hummer Mill / -Silo 3_Trench ; -F15

30A100_RFI_ 384 EXT


Number notification Date of receipt 1/22/2024

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1510
AH1511 7 1/25/2024
AH1512

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date

Number notification 30A100_RFI_..... EXT Date of receipt 1/22/2024

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1513
AH1514 28 2/15/2024
AH1515

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date