CONCRETE COMPRESSIVE STRENGHT TEST REPORT NF EN

12390-3
Number of Test Report 241
Project CONGO – BIOFUEL 1st AGRI HUB - INDUSTRIAL START-UP
Contractor ZEROCK CONSTRUCTION CONGO
Origin of Concrete Zerock Concrete Batching Plant in Loudima

Temperature 33.6 / 33.1 °C Size of specimen (16 x 32 cm) x 3


Pouring date 12/20/2023 Slump test at 0' 15 cm
Mix Design Code 25 - XC4 - D25 - S3 - 42.5N - SHR - S0/1
Composition Cement Water Sand Gravel 1 Gravel 2 Admixture
Type 42,5N - 0/1 5/12,5 16/25 Epsilone HP 565

Quantity(Kg/m3) 450 115 574 260 1018 2


Part of Structure

Silo; Boiler / Footing; Pipe Support / -Silo_04_Base; -Support_04-06

30A100_RFI_332 EXT
Number notification Date of receipt 12/26/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1312
AH1313 7 12/27/2023
AH1314

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date

Number notification 30A100_RFI_..... EXT Date of receipt 12/26/2023

Density STRENGHT (Mpa)


Spec. Tag Age Crushing date Weight (Kg) Load (kN)
(T/m3) Unit Average
AH1315
AH1316 28 1/17/2024
AH1317

Inspectors for : GEOLAB ENI CONGO ZEROCK

Name

Signature

Date