CWB/18-60

Instructions for use

1- Cable preparation
Clean up the cable.
Do not apply silicon grease over the
bonded semi-conductor.

2- Removal of the bonded semi-conductor


Remove the thrust (1) for a remaining length of
25mm of the semi-conductor, by losening the button
(2).
For a remaining length of 30 or 40 mm of the
semi-conductor, set the thrust on the tool (1) before 2 1
setting of the tool on the cable.

3
4
Place the tool on the cable.
Tighten the tool by screwing the red knob (3).
Set, and adjust the penetration of the blade
according to the thickness of the bonded semi-
conductor with the button (4)
Turn the tool clockwise until the tool reaches the
outer sheath.

The tools must be used when the cable is out of tension


by skilled workers who are competent in cable
preparation and know about electrical phenomenons.
Wearing anti-cut gloves is obligatory.
Clean the tools after each utilization.