Professional Documents
Culture Documents
MASL-50KxWH User Manual
MASL-50KxWH User Manual
Line Black
L L
Check product label for specific electrical
Neutral White
N N specifications related to installation.
Ground Green
GND GND
Improper installation will void warranty.
Installation
Dim (+) Purple Sensor Operation and Ajustment
+ +
1. Dim (-)
Remove supply power. Gray/Pink
-
2. Attach mounting bracket to- junction box and position gasket on D2D Test ON Min. 10Ft
Max.
rear of light.
3. Connect wiring. 10' 1'
4. Apply thin coat of silicone to outer edge of housing, to seal light. Max. 40Ft 20Ft
5. Remove center cover and attach light to mounting bracket using 5'
Time Lux Sensitivity
center screw.
6. Restore power to circuit from electrical panel.
7. Adjust sensor settings and aim light heads to desired position. Adjustments
• Sensitivity adjusts motion detection range from 10 ft to
60 ft.
• Time adjusts the duration of time the light stays on after
no motion is detected between 1, 5, and 10 minutes.
• Lux adjusts the ambient light amount at which the light
J-box
turns on automatically, from 5–300 lux.
Crossbar
Gasket Crossbar
Screws
Mount
Washer Base
Power Wires
White (neutral)
Black (positive)
Green (ground)
Mounting
Screw
Silicone
Cap